NanoScan 2s

NanoScan 2s
1 / 14 PagesView full catalog

NanoScan 2s

Product catalog summary
Overview of NanoScan 2s
The NanoScan 2s is a high-precision scanning slit beam profiler designed for laser beam measurement. It features USB connectivity, high speed, accuracy, and a broad dynamic range, supporting detectors for UV to far infrared wavelengths.
Capabilities
The device measures laser beam spatial irradiance profiles and power according to ISO standards. It can handle beam sizes from microns to centimeters and powers from microwatts to kilowatts, with a 16-bit digital controller for enhanced dynamic range and simultaneous measurement of up to 16 beams.
Benefits
  • High measurement accuracy with NIST traceable calibration.
  • Real-time results display with updates up to 20Hz.
  • Capability to measure both pulsed and continuous wave (CW) lasers.
  • Advanced features like Z-axis caustic measurements and M2 propagation ratio values.
  • Automation options with ActiveX commands for system integration.
User Interface
The software is available in standard and professional versions, with the latter offering automation for OEM system integration. The interface is configurable for displaying results on multiple screens.
Integrated Power Meter
Includes a 200mW power meter with a quartz attenuator window for uniform wavelength response, providing accurate relative power measurements when calibrated with a user-supplied power meter.
Detectors and Configurations
Offers various detectors and slit sizes for different beam sizes, supporting silicon, germanium, and pyroelectric detectors across a wide wavelength range.
Versatility and Flexibility
Features USB connectivity and a redesigned rotation mount for vertical or horizontal operation, with a customizable GUI for enhanced user experience.
Measured Beam Results
Measures parameters such as width, centroid position, and ellipticity, providing precise data critical for laser performance analysis.
M² Wizard
Guides users through manual measurements to determine the M² factor using the Rayleigh Method, with an optional translation test fixture for accuracy.
Pulsed Laser Beam Profiling
Profiles pulsed lasers with repetition rates in the 10kHz range and above, using a "peak connect" algorithm and variable scan speed.
Professional Version Features
Includes an ActiveX Automation Server for integration into automated procedures or custom interfaces, supporting various programming environments.
Optional Collimation Fixture
Provides an accurate method for adjusting laser system collimation using a test lens and the NanoScan 2s profiler.
Beam Analysis and Optics Alignment
Emphasizes minimizing divergence angle in beam optics by adjusting optics for the smallest beam diameter, facilitated by a fixed beam profiler for real-time alignment.
Divergence/Collimation Test Fixtures
Utilize a high-quality test lens for focusing beams, requiring a complete NanoScan System, with models available for specific focal lengths and enclosures.
Acquisition and Analysis Software
Offers standard and professional versions with features like source scan head selection and beam parameter computation, supporting both continuous and pulsed modes with 2D/3D displays.
Specifications
Includes USB 2.0 interface, 16-bit signal digitization, and operating temperature range, with detailed scan head dimensions and power requirements.
Detector Operating Space
Charts guide the operating range for different detectors, highlighting responsivity variations, power density limits, and beam diameter considerations.
Ordering Information
Provides a list of NanoScan 2s models and accessories, detailing specifications for each detector type and available software upgrades, with part numbers for ordering.
See more

Catalog excerpts

NanoScan 2s-1

3.4.1 NanoScan 2s 3.4.1.1 NanoScan 2s – Standard Version Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement NanoScan 2s combines the convenience and portability of direct USB connectivity with the speed, accuracy, and dynamic range that users have come to expect from the Photon NanoScan slit based profilers. The NanoScan 2s is available with a silicon, germanium or pyroelectric detector, which allows it to profile lasers of any wavelength from UV to far infrared, out to 100µm and beyond. With the new NanoScan 2s software package, the user can configure the display interface however it is desired; displaying those results of most interest on one easy-to-read screen, or on multiple screens. The NanoScan slit profiler is the most versatile laser beam profiling instrument available today: providing instantaneous feedback of beam parameters for CW and kilohertz pulsed lasers, with measurement update rates to 20Hz. The natural attenuation provided by the slit allows the measurement of many beams with little or no additional attenuation. The high dynamic range makes it possible to measure beams while adjustments to focus are made without having to adjust the profiler. Just aim the laser into the aperture and the system does the rest! NanoScan 2s is a PC-based instrument for the measurement and analysis of laser beam spatial irradiance profiles in accordance with the ISO standard 11146. The scan heads also measure power in accordance with ISO 13694. NanoScan uses the scanning slit, one of the ISO Standard scanning aperture techniques. It can measure beam sizes from microns to centimeters at beam powers from microwatts to over kilowatts, often without attenuation. Detector options allow measurement at wavelengths from the ultraviolet to the infrared. The NanoScan 2s digital controller has 16-bit digitization of the signal for enhanced dynamic range up to 35dB power optical. With the accuracy and stability of the beam profile measurement you can measure beam size and beam pointing with a 3-sigma precision of several hundred nanometers. The software controllable scan speed and a “peak-connect” algorithm allows the measurement of pulsed and pulse width modulated lasers with frequencies of 10kHz and higher*. The NanoScan is also able to measure up to 16 beams, or regions of interest, in the aperture simultaneously. Absolute measurement accuracy is guaranteed by NIST traceable calibration of every NanoScan Measure any wavelength from UV to very far infrared (190nm to >100µm) Instantaneous real time display of results; beam found in less than 300ms and updated at up to 20Hz Waist location can be determined to within ±25µm due to the well-defined Z-axis datum plane of the NanoScan Measure pulsed and CW lasers For pulsed beams the pulse rate is measured and reported From as small as 7µm beams, can be measured directly with guaranteed accuracy and precision Additional high signal to noise ratio can be achieved with averaging Z-axis caustic measurements are available with built-in mechanical linear stage control M2 propagation ratio values available with simple M2 Wizard included with the software. Any beam result can be charted and monitored over time Power levels can be monitored along with spatial measurements to determine if losses are introduced by beam adjustments Log results to text files for independent analysis Automate the system using optional ActiveX Automation commands, available with the PRO version software and scan heads Samples of automation programs included for Excel, VBA, LabView and Visual Basic.net * The minimum frequency is a function of the beam size and the scan speed. This is a simple arithmetic relationship; there must be a sufficient number of pulses during the time that the slits sweep through the beam to generate a meaningful profile. Please refer to Photon’s Application Note, Measuring Pulsed Beams with a Slit-Based Profiler. 187 For latest updates please visit our website:

 Open the catalog to page 1
NanoScan 2s-2

NanoScan 2s Configurable User Interface In addition to new hardware, the NanoScan 2s has an updated integrated software package for the Microsoft Windows Platform, which allows the user to display any of the results windows on one screen. The NanoScan 2s software comes in two versions, STD and PRO. The NanoScan 2s Pro version includes ActiveX automation for users who want to integrate the NanoScan into OEM systems or create their own user interface screens with C++, LabView, Excel or other OEM software packages. File Menu Quick Access Toolbar Ribbon Tabs Results Window User Notes Primary Dock...

 Open the catalog to page 2
NanoScan 2s-3

Integrated Power Meter The silicon and germanium detector equipped NanoScan 2s systems include an integrated 200mW power meter. The scanhead comes with a quartz attenuator window that provides a uniform response across a broad wavelength range. This is a relative power meter that has better than 1.5% correspondence when calibrated with a user-supplied power meter and used in the same configuration as calibrated. The power meter screen in the software shows both the total power and the individual power in each of the beams being measured. % of power within the aperture integrated power measurement...

 Open the catalog to page 3
NanoScan 2s-4

NanoScan 2s Scanhead Model Wavelength Slit Size Aperture Size 1/e2 Beam Diameter Range Spatial Sampling Resolution Profile Digitization Scan Frequency Power Reading Power Aperture Window Laser Type Operating Range Damage Threshold Rotation Mount Scanhead Dimension 700nm - 1800nm 5µm 9mm 20µm-~6mm 5.3nm – 18.3µm 16 bit 1.25, 2.5, 5, 10, 20Hz User calibrated Metalized Quartz (200mW upper limit) CW or Pulsed See Operating Space Chart See Operating Space Chart Standard 63.4mm diameter x 76.8mm long See Mechanical Drawing for details NanoScan 2s Scanhead Model Wavelength Slit Size Aperture Size 1/e2...

 Open the catalog to page 4
NanoScan 2s-5

The Most Versatile and Flexible Beam Profiling System Available With the available range of detectors, slit sizes and apertures the NanoScan 2s provides the maximum versatility in laser beam profiling. NanoScan 2s adds the convenience and portability of direct USB connectivity: no external controllers or power supplies reguired to operate the profiler. In addition the rotation mount has been redesigned to provide a stand for vertical operation, if desired. The mount can be positioned in one of two places. If vertical operation is desired the mount is positioned toward the back of the scanhead...

 Open the catalog to page 5

All Ophir Optronics catalogs and technical brochures

  1. SP932U

    1  Page

  2. ConoPoint-3

    2  Pages

  3. nova catalog

    2  Pages

  4. vega catalog

    2  Pages

  5. BeamWatchAM

    2  Pages

  6. StarBright

    2  Pages

  7. 680274

    1  Page

  8. StarLite

    2  Pages

  9. M200s

    3  Pages

  10. BeamWatch®

    5  Pages

  11. ModeCheck ®

    3  Pages

  12. Nova

    2  Pages

  13. Power Pucks

    1  Page

  14. StarBrigh

    2  Pages

  15. Orion

    2  Pages

  16. Laserstar

    2  Pages

  17. RP Sensors

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.