Catalog excerpts

1.2.3 High Energy Pyroelectric Sensors 10µJ to 40J Features ֺ ֺ Removable diffusers ֺ ֺ PE50-DIF-ER-C mainly for NIR lasers ֺ ֺ PE100BF-DIF-C for very large beams ֺ ֺ Rep rates up to 10kHz ֺ ֺ Measure lasers with pulse widths up to 20ms Very large aperture Diffuser Aperture mm Absorber Type Spectral Range µm (a) Surface Reflectivity % approx. Calibration Accuracy +/-% (a) Max Pulse Width Setting (c) Energy Scales Lowest Measurable Energy mJ (b) Max Pulse Width ms Maximum Pulse Rate pps Noise on Lowest Range µJ Additional Error with Frequency % Linearity with Energy for > 10% of full scale (b) Damage Threshold J/cm2 <100ns 1µs 300µs 2ms Maximum Average Power W Maximum Average Power Density W/cm2 Weight kg Version Part Number Notes: (a) Calibrated at 532nm and 1064nm Calibrated at 1064nm, Calibrated at 532nm Calibrated at 532nm, 1064nm and only 2100nm and 2940nm and 1064nm only 1550nm only Notes: (b) With the "user threshold" setting set to minimum. For other settings, the spec is for >10% of full scale or greater than twice the "user threshold", whichever is greater. For use with StarBright, StarLite, Nova II, Vega or Juno. The sensors will operate with older Ophir meters and PC interfaces but do not support the threshold function and may give inaccurate readings with the diffuser in and therefore it is not recommended to use these sensors with older Ophir meters and PC interfaces. The user threshold feature allows adjustment of the internal threshold up to 25% of full scale if desired to avoid false triggering in noisy environments. For further information, see the FAQs on our Website. Notes: (c) With the Laserstar, Pulsar, USBI, Quasar and Nova/Orion with adapter only 2 of the 5 pulse width settings are available. For the PE50-DIF-ER-C, the 30µs and 1ms settings and for the PE100BF-DIF-C, the 1ms and 10ms settings. Furthermore, with the diffuser mounted, the sensor may saturate at lower than the maximum energy in some cases. Therefore it is recommended to use these sensors with the newer meters/PC interfaces. Removable Diffuser Assembly Removable Diffuser Assembly For latest updates please
Open the catalog to page 1All Ophir Optronics catalogs and technical brochures
-
SP932U
1 Pages
-
ConoPoint-3
2 Pages
-
nova catalog
2 Pages
-
nova ii catalog
2 Pages
-
vega catalog
2 Pages
-
BeamWatchAM
2 Pages
-
StarBright
2 Pages
-
680274
1 Pages
-
P920 Beam Profiling Camera
1 Pages
-
L2000W-PF-120
1 Pages
-
L40(250)A-BB-50
1 Pages
-
IS1.5-VIS-FPD-800
1 Pages
-
Optimet Industrial Catalog 2017
34 Pages
-
Energy Sensors Accessories
1 Pages
-
StarLite
2 Pages
-
Power Meters & Interfaces
1 Pages
-
Power Meters Vega
2 Pages
-
Goniometric Radiometers
3 Pages
-
1780 Instantly measure M 2
2 Pages
-
M200s
3 Pages
-
NanoScan 2s
14 Pages
-
LBS-100 Attenuato
1 Pages
-
LBS-400 Beam Splitters
1 Pages
-
maging UV lasers
1 Pages
-
Near Field Profilers
1 Pages
-
BeamWatch®
5 Pages
-
ModeCheck ®
3 Pages
-
Nova
2 Pages
-
Calorimetric Power Meter
1 Pages
-
Power Pucks
1 Pages
-
High Power Thermal Sensors
1 Pages
-
Thermal Power Sensors
1 Pages
-
ompact Juno USB Interface
7 Pages
-
StarBrigh
2 Pages
-
Standard Photodiode Sensors
3 Pages
-
Medium Power BeamTrack-Power
1 Pages
-
Low Power BeamTrack-Power /
1 Pages
-
YAG Focal Spot Analyzer
2 Pages
-
Standard OEM Thermal Sensors
1 Pages
-
PC Interfaces Juno
5 Pages
-
Photodiode Energy Sensors
5 Pages
-
Pyroelectric Energy Sensors
1 Pages
-
Orion
2 Pages
-
Laserstar
2 Pages
-
RP Sensors
2 Pages
-
Pyroelectric Energy Sensors
1 Pages
-
Special Photodiode Sensors
1 Pages
Archived catalogs
-
Laser Beam Profile Catalog
42 Pages
-
Laser Beam Prifile catalog
42 Pages
-
Complete Catalogue OPHIR
155 Pages
-
Laser Beam Profile
42 Pages
-
Laser Power Meters
4 Pages