Product Overview: The T-WNB-3D-240 Sensor is a WattNode 208/240 VAC 3-phase Delta/Wye kWh Transducer Sensor designed for sub-metering, net-metering, energy management, and performance contracting applications. It provides accurate kilowatt-hour measurements even for non-sinusoidal waveforms and is compatible with Magnelab AC Current Transformers and a Pulse Input Adapter.
Key Features:
  • Supports 1, 2, or 3-phase measurements in 2, 3, or 4 wire configurations.
  • Compatible with a wide range of CTs (5 to 1500 amps).
  • Easy installation and wiring with detachable terminal blocks.
  • Pulse output compatible with pulse input logger models.
  • Small size for installation in existing panels or junction boxes.
  • Diagnostic LEDs for installation confirmation.
  • Bidirectional metering for solar and wind power generation.
  • Line powered, requiring no external supply.
  • UL, cUL Listed and CE Mark certified for safety and use in North America and the EU.
Specifications:
  • Operating voltage range: ±20% of nominal.
  • Frequency: 60 Hz.
  • CT input: 0-0.5 VAC operating, 3 VAC maximum.
  • Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V.
  • Operating temperature range: -30 to 60°C (-22 to 140°F).
  • Operating humidity range: 0 to 90% RH, non-condensing.
  • Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.).
  • Weight: 295 g (10.4 oz.).
  • Number of data channels: 2.
Configuration Ranges:
  • 1 Phase 2 Wire 208V (No neutral).
  • 1 Phase 2 Wire 240V (No neutral).
  • 1 Phase 3 Wire 120V/240V.
  • 3 Phase 3 Wire 208V (No neutral).
  • 3 Phase 4 Wire 120V/208V.
Accuracy: ±0.45% of reading + 0.05% FS through 25th harmonic, with potential variation from 1.5% to 4% depending on CT used and line variation.
Contact Information:
  • Sales: Email [email protected], Call 1-508-759-9500, Toll-free 1-800-564-4377.
  • Technical Support: Contact via www.onsetcomp.com/support/contact, Call 1-508-759-9500, Toll-free 1-877-564-4377.
  • Address: Onset Computer Corporation, 470 MacArthur Boulevard, Bourne, MA 02532.
See more

Catalog excerpts

T-WNB-3D-240 Sensor-1

The WattNode provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. This WattNode Delta-connection kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel. This model supports a 3-phase Delta-connection of 208/240 VAC. Supported Measurements: Kilowatt Hours (kWh) Key Advantages: • Measures 1, 2, or 3 phases in 2, 3, or 4 wire configurations. • Use with wide choice of CTs (sold separately),ratings from 5 to 1500 amps. • Accurate measurement of 1-,2-, or 3-phase configurations. • Easy to install and wire. • Pulse output - Compatible with pulse input logger models. • Small size - Can be installed in existing service panels or junction boxes. • Diagnostic LEDs - Confirms proper installation for all phases. • Bidirectional metering - Net metering for PV (photovoltaic) solar and wind power generation with only one meter. • Metering of variable frequency drives. • Line powered - No external supply required. • Detachable terminal blocks - Easy to install and remove. • UL, cUL Listed - Designed and tested for safety and use throughout North America. • CE Mark - Can be installed throughout the EU.

 Open the catalog to page 1
T-WNB-3D-240 Sensor-2

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V Operating temp range: -30 to 60°C (-22 to 140°F) Operating humidity range: 0 to 90% RH, non-condensing Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.) Weight: 295 g (10.4 oz.) Number of data channels: 2 To download the manual from Continental Control Systems LLC click here. Click here to view a typical installation Delta or Wye configuration ranges: 208, 480 Volts AC 1 Phase 2 Wire 208V (No neutral)...