Catalog excerpts
The WattNode provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. This WattNode Delta-connection kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel. This model supports a 3-phase Delta-connection of 208/240 VAC. Supported Measurements: Kilowatt Hours (kWh) Key Advantages: • Measures 1, 2, or 3 phases in 2, 3, or 4 wire configurations. • Use with wide choice of CTs (sold separately),ratings from 5 to 1500 amps. • Accurate measurement of 1-,2-, or 3-phase configurations. • Easy to install and wire. • Pulse output - Compatible with pulse input logger models. • Small size - Can be installed in existing service panels or junction boxes. • Diagnostic LEDs - Confirms proper installation for all phases. • Bidirectional metering - Net metering for PV (photovoltaic) solar and wind power generation with only one meter. • Metering of variable frequency drives. • Line powered - No external supply required. • Detachable terminal blocks - Easy to install and remove. • UL, cUL Listed - Designed and tested for safety and use throughout North America. • CE Mark - Can be installed throughout the EU.
Open the catalog to page 1Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V Operating temp range: -30 to 60°C (-22 to 140°F) Operating humidity range: 0 to 90% RH, non-condensing Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.) Weight: 295 g (10.4 oz.) Number of data channels: 2 To download the manual from Continental Control Systems LLC click here. Click here to view a typical installation Delta or Wye configuration ranges: 208, 480 Volts AC 1 Phase 2 Wire 208V (No...
Open the catalog to page 2All ONSET catalogs and technical brochures
-
HOBO® MX1105 Data Logger
3 Pages
-
HOBO® MX100 Data Logger
3 Pages
-
HOBO UX90-004x
6 Pages
-
HOBO UX90-005x/-006x
7 Pages
-
HOBO UX100-002x
6 Pages
-
HOBO UX100-003
8 Pages
-
HOBO UX100-014M
8 Pages
-
InTemp® CX403
3 Pages
-
HOBO® MX2204 Data Logger
3 Pages
-
InTemp® CX702 Data Logger
2 Pages
-
InTemp® CX602 Data Logger
2 Pages
-
InTemp® CX5000
2 Pages
-
S-FS-TRMSA Sensor
2 Pages
-
S-RGF-M002 Sensor
2 Pages
-
HOBO® Energy Logger
2 Pages
-
S-THB-M008 Sensor
3 Pages
-
T-VER-PX3UL Sensor
2 Pages
-
S-WCF-M003 Sensor
3 Pages
-
HOBO® MX2301A Data Logger
3 Pages
-
HOBO® RX3000 Data Logger
3 Pages
-
RXW-THC-xxx Sensor
3 Pages
-
MX1102
2 Pages
-
ZW series
2 Pages
-
HOBO MX2300
2 Pages
-
UX90
2 Pages
-
HOBO USB Micro Station
2 Pages
-
Catalog 2014
46 Pages
-
pressure data-logger
8 Pages