TM-2110 - Basic Unit (replaced with the TM-3110)
1 / 28Pages

Catalog excerpts

TM-2110 - Basic Unit (replaced with the TM-3110) - 1

Digital Tachometers / Sensors

Open the catalog to page 1
TM-2110 - Basic Unit (replaced with the TM-3110) - 2

Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer. Rotation Detectors Selection Guide encoder with a 12 VDC drive ¥ When using a rotary4) TM-2100 Series (P. TM-5100 (P. 17) Electromagnetic Rotation Detectors (Internal Gear Type) MP-610 (P. 14) MP-800 Series (P. 13) ¥ Electromagnetic Rotation Detectors (Internal Gear Type) Ð Features a) Direct connection to the rotating shaft is all that is required. A flexible coupling is recommended for the direct connection method. b) Non-contact detection...

Open the catalog to page 2
TM-2110 - Basic Unit (replaced with the TM-3110) - 3

Encoders ¥ Rotaryrotation torqueÐ Features a) Small ¥ Photoelectric rotation detectorspeed This device measures the rotation b) Capable of measuring large P/R values; wide selection range c) Can perform detection of low-speed rotations (close to zero) d) Choice of two types of power supply depending on the model, AC or DC. e) Wide selection of models for different applications either by utilizing the light reflected from reflective tape, or from the contrast in the light received that is caused by the color of the shaft or by a difference in level. ¥ Photoelectric Rotation Detectors Ð...

Open the catalog to page 3
TM-2110 - Basic Unit (replaced with the TM-3110) - 4

Rotation Display Units Selection Guide Model No. Power requirement Output, Specifications, (Power supply for the Compatible Detectors detector) etc. MP Series SP-405ZA LG Series RP Series IP Series VP-202, 1220 OM-1200 LG Series MP Series MP Series LG Series RP Series TM-2130 Analog output TM-2140 Contact output CT-6520 Compatible with Low Pulse Sensors Multifunction Model BCD output 100 to 240 VAC Analog output 11 to 15 VDC Pulse output (12 VDC/100 mA) Alarm contact output TM-5100 BCD output Analog output Comparator output RS-232C 2-channel calculation 100 to 240 VAC (5 VDC /150 mA) (Total...

Open the catalog to page 4
TM-2110 - Basic Unit (replaced with the TM-3110) - 5

CONTENTS Rotation Detectors Selection Guide Rotation Units Selection Guide Rotation Detectors Notes on Detection Gears 6 Electromagnetic Type (External Gear Type) [Modules 1 to 3] General-purpose type MP-9100 7 to 10 With a directly attached cable MP-911 7 to 10 Measurable for high speed rotation MP-9120 7 to 10 Oil-proof type MP-930 7 to 10 Oil-proof/Heat-resistant type MP-935 7 to 10 (up to 150¡C) Heat-resistant type MP-936 7 to 10 (up to 220¡C) Long body type MP-940A 7 to 10 Compact type MP-950 7 to 10 Long body type MP-954 7 to 9, 11 Compact type MP-962 7 to 9, 11 Ultra-compact type...

Open the catalog to page 5
TM-2110 - Basic Unit (replaced with the TM-3110) - 6

Rotation Detectors Notes on Detection Gears Detection Gear •In theory, a detector is a magnetic body. Since it has a large magnetic permeability, soft metals (such Rotation Detectors as S20C, SS41) are generally used. When performing normal rotating speed measurements, if the gate time is specified at 1 second, using a 60 P/R gear enables direct readout of the rotating speed by the counter. Shape •Fig. 1 showsof a Detection Gear various types of external rotors (detection gears and so detector output waveforms from Notes on Detection Gears forth). If the gear is a spur gear, an involute...

Open the catalog to page 6
TM-2110 - Basic Unit (replaced with the TM-3110) - 7

Electromagnetic Rotation Detectors The MP-900/9000 Series detectors have been designed primarily to detect frequency signals in proportion to the rotating speed by bringing the detector in close proximity to the addendum of a detection gear fitted to a rotating shaft (sine wave output). Various types are available, from general-purpose, oil-proof and heat-resistant types through to user-customized types, enabling you to select the one that best suits your application. Extension cables, signal cables and connectors can also be purchased separately. Rotation Detectors Mounting example...

Open the catalog to page 7
TM-2110 - Basic Unit (replaced with the TM-3110) - 8

•MP-900/9000 Series Specifications Detector Rotation Detectors External Gear Type With cable attached Low impedance (Measurable for high speed rotation) Inductance (mH) [1 kHz, typ.] Impedance (½) [1 kHz, typ.] Output voltage (Vp-p) [1 kHz, typ.]* Detectable frequency range (Hz) * * Detection gear module Operating temperature range 2 Surrounding magnetic field (T) Detector Long body Compact type (With cable attached) Ultra-compact type Compact type (With cable attached) Long body Detectable frequency range (Hz) * * Detection gear module Operating temperature range 2 Shock resistance (m/s )*...

Open the catalog to page 8
TM-2110 - Basic Unit (replaced with the TM-3110) - 9

•The Relationship between the Gap and Detection Rotation Range ¥ MP-900/9000 Series: Rotating speed (r/min) that can be measured Rotation Detectors (1) The relationship between the gap between the detector and the detection gear and the detection range (Lowest measurable value) is given in the tables below. (2) The rotating speed range is that for which an output voltage of 0.5 Vp-p or greater can be maintained (load resistance = 10 k½). (3) The rotating speed that can be measured varies according to the type of display unit used. Note: When a 60-tooth gear is used Lowest measurable value...

Open the catalog to page 9
TM-2110 - Basic Unit (replaced with the TM-3110) - 10

External Gear Type ¥MP-930 2-Lock nuts (width across flats 21) ¥MP-936 2-Lock nuts (width across flats 21) M16 X 1 2-Lock nuts (width across flats 21) 2-Lock nuts (width across flats 17) Lock nuts (width across flats) 2-Lock nuts (width across flats 21) Rotation Detectors M16 x 1 2-Lock nuts (width across flats 21) 2-Lock nuts (width across flats 21)

Open the catalog to page 10
TM-2110 - Basic Unit (replaced with the TM-3110) - 11

2-Lock nuts (width across flats 21) Lock nuts (width across flats 7) External Gear Type Rotation Detectors 2-Lock nuts (width across flats 14) 2-Lock nuts (width across flats 17) 500 Detailed drawing of part A (2/1) 2-Lock nuts (width across flats 36)

Open the catalog to page 11
TM-2110 - Basic Unit (replaced with the TM-3110) - 12

Magnetoelectric Rotation Detector MP-981 For detection of low-to-medium speeds These detectors utilize magnetic flux response (the resistance value changes according to the magnetic flux). The internal mechanism comprises magnetic resistance elements, permanent magnets, a direct current amplifier, and a voltage regulator. Detection can be performed as square wave output over a wide range from ultra-low speeds to high speeds (1 to 20,000 r/min [60 P/R]). There are two models: the general-purpose MP-981 model and the waterproof AP-981 model. ¥ Output from ultra-low to high speeds (1 to 20,000...

Open the catalog to page 12

All Onosokki catalogs and technical brochures

  1. SE-1200

    2 Pages

  2. HR-6800

    3 Pages

  3. GE-1400

    2 Pages

  4. Stand Specs

    1 Pages

  5. sr-2200

    8 Pages

  6. MI Series

    6 Pages

  7. GS-7710

    2 Pages

  8. GS-5050

    2 Pages

  9. GS-1713/1730

    3 Pages

  10. GS-1713/1730

    4 Pages

  11. BS Series

    2 Pages

  12. DG-4000

    4 Pages

  13. EG-225

    2 Pages

  14. RP-7400

    2 Pages

  15. LG-9200

    2 Pages

  16. LG-9200

    2 Pages

  17. LG-9200

    2 Pages

  18. SE-1100

    4 Pages

  19. HT-6200

    4 Pages

  20. HT-5500

    3 Pages

  21. HT series

    3 Pages

  22. DG-525H

    6 Pages

  23. DG-3610

    2 Pages

  24. FT-7200

    8 Pages

  25. CT-6520B

    4 Pages

  26. TM-3100 Series

    12 Pages

  27. HT-5100

    4 Pages

  28. HT-3100

    4 Pages

  29. FV-1300

    4 Pages

  30. DS-3000

    2 Pages

  31. SE 2500

    4 Pages

  32. SE 1620

    2 Pages

  33. SE 1520

    2 Pages

  34. SE 1100

    4 Pages

  35. CT - 6520

    4 Pages

  36. FT-2500

    8 Pages

  37. SE-1620

    2 Pages

  38. GE-1200

    2 Pages

Archived catalogs

  1. HT-6100

    4 Pages

  2. SE-2500

    4 Pages

  3. HT-6100

    4 Pages