sr-2200 - 1

Sound Level Meter LA-3570 / 3560 / 3260 Measure, listen, record and checkall with the same device Perform more than a sound Level Meter

Open the catalog to page 1
sr-2200 - 2

series Sound Level Meter You can now measure while listening, and record and check all with the same device The LA-3000 series are cost-effective sound level meters that come standard with a headphone output and an auto memory function. By adding a wide range of options, you can upgrade the models into higher-performance equipment to serve as analyzers, recorders, comparators, and loudness meters. These sound level meters bring about innovation to field measurements. • Large easy to see screen. Direct keys for easy operation. • Can make measurements from some distance away from a sound...

Open the catalog to page 2
sr-2200 - 3

With the addition of options, the Sound Level Meter evolves into varied products! Sound Analyzer Sound Comparator By means of real-time octave analysis and FFT analysis, you can determine where a particular distinctive sound occurs along the frequency of a measuring sound. The use of bandpass-filter is effective in a sound source probing. With the help of instantaneous value and Leq*, you can make OK/NG judgments on products. Well-suited for embedding into equipment used on production lines. *Equivalent Continuous Sound Pressure Level Loudness Meter Sound Recorder The Sound Level Meter...

Open the catalog to page 3
sr-2200 - 4

1/1 Real-time Octave Analysis Function : LA-0351 1/3 Real-time Octave Analysis Function : LA-0352 <The use of headphones helps to perform sound probing of a specific sound, such as an unusual noise> In Filteii mode, you can make level evaluations in a single frequency band. By focusing solely on a particular frequency band in which a specific unusual noise occurs and measuring the sound pressure level, you can find where the noise is coming from. While wearing the headphones, you can listen to sounds only in the frequency band you selected. At this time, switchover to level display or trend...

Open the catalog to page 4
sr-2200 - 5

Sound Recording Function: LA-0354 It becomes possible for you record any unusual sounds that you may hear on site into an SD/SDHC card in WAVE format. And since you can play back those recordings on the sound level meter, you can also check that recordings have been made without fail on site. You can also save trend data at the same time by allowing the playback of long-duration data recordings. With instantaneous display of this data at the time of reproduction, you can quickly find a distinct sound and start playing back from that point in time. The OS-2000 series (option) is useful for...

Open the catalog to page 5
sr-2200 - 6

Extension cable for microphone AG-3400 series extension cable (Compliant to CE marking) Sound Calibrator Carrying case Compliant with JIS C1515: 2004, these sound calibrators are essential equipment for noise measurements. The SC-3120 is a Class 1/C-rated piston phone-type sound calibrator. It delivers sound pressure of 114 dB at 250 Hz. Please use the SC-3120 with the LA-3000-series Sound Level Meters that are compliant with JIS C1509. The SC-2120A is a Class 2-rated speaker-type calibrator that generates sound pressure of 94 dB at 1 kHz. Battery cell x 4 pieces Instruction manual This is...

Open the catalog to page 6
sr-2200 - 7

Intrinsic noise A:14 dB or less C:20 dB or less Z:28 dB or less A:19 dB or less C:24 dB or less Z:30 dB or less A:20 dB or less C:24 dB or less Z:30 dB or less Sensitivity level (re. = 1 V/Pa) Microphone preamplifier Linearity range Wide range: 110 dB / normal range : 80 dB Level range Reference range Time weighting F (fast), S (slow), I (impulse), and 10 ms Frequency weighting Measurement items Lp, Leq, LE, Lpeak, Lmax, Lmin LN (LH1, L5, L10, L50, L90, L95, LLO, LAV, and two more any LN data) Sampling interval 15.6 µs (Lp, Leq, LE, Lmax, Lmin, Lpeak), 100 ms (LN) Measurement (calculation)...

Open the catalog to page 7
sr-2200 - 8

Power supply Type AA battery (alkaline battery cell or rechargable battery cell ) x 4 pieces or AC adapter (PB-7090 ... power consumption: approx. 7 VA when AC100V in used ) Battery life (continuous use)*2 Alkaline battery cell LR6 : approx. 8 hours Ni-MH secondary battery : approx. 8 hours Operating (storage) temperature range Operating (storage) humidity range 22 to 90 % RH (10 to 90 %RH) with no condensation Approx. 379 (H) x 106 (W) x 49.3 (D) mm Approx. 680 g (including batteries) Outer dimensions Approx. 630 g (including batteries) AC adapter (PB-7090), signal cable (AX-501),...

Open the catalog to page 8

All Onosokki catalogs and technical brochures

  1. SE-1200

    2 Pages

  2. HR-6800

    3 Pages

  3. GE-1400

    2 Pages

  4. Stand Specs

    1 Pages

  5. MI Series

    6 Pages

  6. GS-7710

    2 Pages

  7. GS-5050

    2 Pages

  8. GS-1713/1730

    3 Pages

  9. GS-1713/1730

    4 Pages

  10. BS Series

    2 Pages

  11. DG-4000

    4 Pages

  12. EG-225

    2 Pages

  13. RP-7400

    2 Pages

  14. LG-9200

    2 Pages

  15. LG-9200

    2 Pages

  16. LG-9200

    2 Pages

  17. SE-1100

    4 Pages

  18. HT-6200

    4 Pages

  19. HT-5500

    3 Pages

  20. HT series

    3 Pages

  21. DG-525H

    6 Pages

  22. DG-3610

    2 Pages

  23. FT-7200

    8 Pages

  24. CT-6520B

    4 Pages

  25. TM-3100 Series

    12 Pages

  26. HT-5100

    4 Pages

  27. HT-3100

    4 Pages

  28. FV-1300

    4 Pages

  29. DS-3000

    2 Pages

  30. SE 2500

    4 Pages

  31. SE 1620

    2 Pages

  32. SE 1520

    2 Pages

  33. SE 1100

    4 Pages

  34. CT - 6520

    4 Pages

  35. FT-2500

    8 Pages

  36. SE-1620

    2 Pages

  37. GE-1200

    2 Pages

Archived catalogs

  1. HT-6100

    4 Pages

  2. SE-2500

    4 Pages

  3. HT-6100

    4 Pages