REMOTE CONDENSERS HVL
20Pages

{{requestButtons}}

Catalog excerpts

REMOTE CONDENSERS HVL - 1

REMOTE CONDENSERS

Open the catalog to page 1
REMOTE CONDENSERS HVL - 3

3 Advanced Heat Exchangers Heat Exchange Finned Coils Batterie di scambio termico _All finned coils of remote condensers are produced with copper pipes and aluminium fins with high efficiency pyramidal corrugation _The frame of finned coils is produced in galvanized steel with thickness suitable to weight of heat exchanger. _All pipes are expanded on aluminium counter-endplates to avoid any contact between copper pipes and steel frame and therefore any possible pipe damage. _Endplate holes corresponding to header nipples are larger to avoid that vibrations and dilatations can damage pipes....

Open the catalog to page 3
REMOTE CONDENSERS HVL - 4

Quick Selection / Selezione rapida Condensers can be selected if you know type of compressor, cooling capacity and working conditions according to following scheme and parameters. La selezione del condensatore può essere effettuata conoscendo la tipologia di compressore, la potenza frigorifera e le condizioni di lavoro secondo lo schema e i parametri indicati di seguito. Compressor Type / Tipo di compressore K1 Air Temperature Difference / Differenza di temperatura aria T ambient - T condensation / T ambiente - T condensazione K2 Air Temperature Ambient / Temperatura aria ambiente T amb. °C...

Open the catalog to page 4
REMOTE CONDENSERS HVL - 5

5 Advanced Heat Exchangers Option / Opzioni PLEASE CHECK PAGE 8 TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE CONSULTARE PAGINA 8 PER CONOSCERE LA DISPONIBILITÀ DELLE OPZIONI Cablaggio elettroventilatori Quadro elettrico Fans with wiring in terminal box Fans with wiring in electrical box including switches and thermal protection for each fan and general switch. Speed Regulator “by step” Fans with wiring in electrical box including speed regulator “by step”. This system lets you keep steady condensation pressure stopping not necessary fans of the condensers. You can set the speed...

Open the catalog to page 5
REMOTE CONDENSERS HVL - 6

Remote condensers Option / Opzioni PLEASE CHECK PAGE __ TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE Kit supporti per flusso aria verticale Kit supports for vertical air flow The unit are standard always shipped and packed in vertical configuration with horizzontal air flow. In case of vertical air flow is necessary to add the option “SV” kit supports for vertical air flow. Is always necessary specify in the order the unit with correct air flow direction ( V = vertical air flow ; H = horizzontal air flow ) because the circuitation of the units is realized to be drainable in the...

Open the catalog to page 6
REMOTE CONDENSERS HVL - 7

Condensatori remoti 7 Advanced Heat Exchangers Adiabatic system / Sistemi adiabatici Nozzle dimension and quantity are selected to get the correct water flow and the best distribution on the finned block. Dimensione e numero di ugelli sono ottimizzati e calcolati per ottenere la corretta portata d’acqua e la miglior distribuzione possibile sul pacco alettato. La pressione minima dell’acqua richiesta è di 2,5 bar. Minimum required water pressure is 2,5 bar. Le elettrovalvole di carico e scarico vengono gestite dal controllo dei ventilatori (nel caso venga selezionato uno dei quadri elettrici...

Open the catalog to page 7
REMOTE CONDENSERS HVL - 8

The adiabatic system PD is supplied completely assembled and ready to be used. Il sistema adiabatico PD viene fornito completamente montato e pronto all’uso. The structure PD is integrated in the unit and constituted by a water distribution system completely openable, the plastic panels and the trays for water collection and discharge. La struttura PD è integrata nella macchina ed è composta da un sistema di distribuzione dell’acqua completamente ispezionabile, dai pannelli in materiale plastico, dalle vasche di raccolta e scarico acqua. The water distribution system is designed to drain...

Open the catalog to page 8
REMOTE CONDENSERS HVL - 9

Condensatori remoti HVL ORDER CODE CODICI DI ORDINAZIONE 9 Advanced Heat Exchangers Fans connection / Collegamento ventilatori D=∆ Y= Number of poles / Numero di poli X = 6S M=6 L=8 Coil type / tipo batteria Number of fans / Numero di ventole ( 4÷20) Diameter of fans / Diametro ventilatori 80 = Ø 800mm 91 = Ø 910mm Type / Esecuzione HVL = V shape double row fans Esecuzione a V doppia fila di ventole

Open the catalog to page 9
REMOTE CONDENSERS HVL - 10

Fan number Numero ventilatori

Open the catalog to page 10
REMOTE CONDENSERS HVL - 11

Advanced Heat Exchangers Fan number Numero ventilatori

Open the catalog to page 11
REMOTE CONDENSERS HVL - 12

Numero ventilatori Notes / Note (a) Capacity calculation based on ENV327 / Rese calcolate secondo ENV327 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE30 version for CE45 version please contact our technical office / Diametri validi per versione CE30, per versioni CE45 contattare il nostro ufficio tecnico (e) Dimension and weight refer to the standard execution and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per...

Open the catalog to page 12
REMOTE CONDENSERS HVL - 13

Advanced Heat Exchangers 6053 1140 1140 1140 Lifting points Lifting points Lifting points Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico

Open the catalog to page 13
REMOTE CONDENSERS HVL - 14

Fan number Numero ventilatori

Open the catalog to page 14
REMOTE CONDENSERS HVL - 15

Advanced Heat Exchangers Fan number Numero ventilatori

Open the catalog to page 15
REMOTE CONDENSERS HVL - 16

Numero ventilatori Notes / Note (a) Capacity calculation based on ENV327 / Rese calcolate secondo ENV327 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE30 version for CE45 version please contact our technical office / Diametri validi per versione CE30, per versioni CE45 contattare il nostro ufficio tecnico (e) Dimension and weight refer to the standard execution and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per...

Open the catalog to page 16
REMOTE CONDENSERS HVL - 17

Advanced Heat Exchangers 6053 1140 1140 1140 Lifting points Lifting points Lifting points Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico

Open the catalog to page 17

All Onda catalogs and technical brochures

  1. PLATE & FRAME

    24 Pages

  2. CRW Condensers

    16 Pages

  3. OIL COOLER

    2 Pages

  4. L CONDENSERS

    20 Pages

  5. C CONDENSERS

    20 Pages

  6. BRAZED PLATES

    44 Pages