LIQUID COOLERS
Open the catalog to page 1Raffreddatori di liquido MVL_PMVL Advanced Heat Exchangers Heat Exchange Finned Coils Batterie di scambio termico _All finned coils of liquid coolers are produced with copper pipes and aluminium fins with high efficiency pyramidal corrugation _The frame of finned coils is produced in galvanized steel with thickness suitable to weight of heat exchanger. _All pipes are expanded on aluminium counter-endplates to avoid any contact between copper pipes and steel frame and therefore any possible pipe damage. _Tutte le batterie a pacco alettato dei Raffreddatori di liquido sono realizzate con tubi...
Open the catalog to page 3Liquid coolers MVL_PMVL Quick Selection / Selezione rapida Liquid cooler can be selected if you know cooling capacity and working conditions according La selezione del raffreddatore di liquido può essere effettuata conoscendo la potenza da to following scheme and parameters. smaltire richiesta e le condizioni di lavoro secondo lo schema e i parametri indicati di seguito. Ambient temperature coefficient K1 / Coefficiente temperatura ambiente K1 Tambient / T ambiente K1 0% ethylene glycol / K1 0% glicole etilenico K1 35% ethylene glycol / K1 35% glicole etilenico Fluid temperature /...
Open the catalog to page 4Raffreddatori di liquido MVL_PMVL Advanced Heat Exchangers Option / Opzioni PLEASE CHECK PAGE 8 TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE CONSULTARE PAGINA 8 PER CONOSCERE LA DISPONIBILITÀ DELLE OPZIONI Cablaggio elettroventilatori Fans with wiring in terminal box Electrical Panel AC Fans with wiring in electrical box including switches and thermal protection for each fan and general switch. Electrical panel EC Fans with wiring in electrical box including protection fuses for single fan. The EC fan control module ( code RE ) is supplied separatly, in this configuration the fans...
Open the catalog to page 5Liquid coolers MVL_PMVL Option / Opzioni PLEASE CHECK PAGE __ TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE CONSULTARE PAGINA __ PER CONOSCERE LA DISPONIBILITÀ DELLE OPZIONI Kit supports for vertical air flow Kit supporti per flusso aria verticale The unit are standard always shipped and packed in vertical configuration with horizzontal air flow. In case of vertical air flow is necessary to add the option “SV” kit supports for vertical air flow. Is always necessary specify in the order the unit with correct air flow direction ( V = vertical air flow ; H = horizzontal air flow )...
Open the catalog to page 6Raffreddatori di liquido MVL_PMVL Advanced Heat Exchangers Adiabatic system / Sistemi adiabatici Nozzle dimension and quantity are selected to get the correct water flow and the best distribution on the finned block. Dimensione e numero di ugelli sono ottimizzati e calcolati per ottenere la corretta portata d’acqua e la miglior distribuzione possibile sul pacco alettato. La pressione minima dell’acqua richiesta è di 2,5 bar. Minimum required water pressure is 2,5 bar. Le elettrovalvole di carico e scarico vengono gestite dal controllo dei ventilatori (nel caso venga selezionato uno dei...
Open the catalog to page 7Liquid coolers MVL_PMVL The adiabatic system PD is supplied completely assembled and ready to be used. Il sistema adiabatico PD viene fornito completamente montato e pronto all’uso. The structure PD is integrated in the unit and constituted by a water distribution system completely openable, the plastic panels and the trays for water collection and discharge. La struttura PD è integrata nella macchina ed è composta da un sistema di distribuzione dell’acqua completamente ispezionabile, dai pannelli in materiale plastico, dalle vasche di raccolta e scarico acqua. The water distribution system...
Open the catalog to page 8Raffreddatori di liquido MVL_PMVL ORDER CODE CODICI DI ORDINAZIONE Advanced Heat Exchangers Fans connection / Collegamento ventilatori D=Δ Y= Number of poles / Numero di poli X = 6S M=6 L=8 Coil type / tipo batteria Number of fans / Numero di ventole ( 4 20 ) Diameter of fans / Diametro ventilatori 80 = Ø 800mm 91 = Ø 910mm Type / Esecuzione MVL = V shape double row fans - tubes Ø12mm Esecuzione a V doppia fila di ventole - tubi Ø12mm PMVL = V shape double row fans - tubes Ø16mm Esecuzione a V doppia fila di ventole - tubi Ø16mm
Open the catalog to page 9Fan number Numero ventilatori
Open the catalog to page 10Advanced Heat Exchangers Fan number Numero ventilatori
Open the catalog to page 11MVL80_C_D Ø 800mm Connection IN / OUT(d) Model Weight kg (e) Connessioni IN / OUT(d) Numero ventilatori Notes / Note (a) Capacity calculation based on ENV1048 / Rese calcolate secondo ENV1048 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per disegni e dati specifici...
Open the catalog to page 1213 Advanced Heat Exchangers Fixing point Fixing point Lifting points Fixing point Fixing point Fixing point Lifting points Lifting points Fixing point Fixing point Fixing point Fixing point Lifting points Lifting points Lifting points Fixing point Fixing point Fixing point Fixing point Fixing point Lifting points Lifting points Lifting points Fixing point Fixing point Fixing point Fixing point Fixing point Fixing point Lifting points Lifting points Lifting points Fixing point Fixing point Fixing point Fixing point Fixing point Fixing point Fixing point Lifting points Lifting points Lifting...
Open the catalog to page 13Liquid coolers PMVL Fan number Numero ventilatori
Open the catalog to page 14Raffreddatori di liquido PMVL 15 Advanced Heat Exchangers Fan number Numero ventilatori
Open the catalog to page 15Liquid coolers PMVL PMVL80_C_D Ø 800mm Connection IN / OUT(d) Model Weight kg (e) Connessioni IN / OUT(d) Numero ventilatori Notes / Note (a) Capacity calculation based on ENV1048 / Rese calcolate secondo ENV1048 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per disegni e...
Open the catalog to page 16All Onda catalogs and technical brochures
-
PLATE & FRAME (US MARKET)
24 Pages
-
PLATE & FRAME
24 Pages
-
MARINE CONDENSER
2 Pages
-
CRW Condensers
16 Pages
-
HYBRID FILM EVAPORATOR
2 Pages
-
P PEG S&T EVAPORATORS
5 Pages
-
OVS SEPARATORS GEN.2
12 Pages
-
RL & RL-V LIQUID RECEIVERS
12 Pages
-
OIL COOLER
2 Pages
-
LVC CONDENSERS (USA MARKET)
12 Pages
-
FLS-FLT S&T EVAPORATORI
2 Pages
-
B CONDENSERS (EUROPE MARKET)
16 Pages
-
B CONDENSERS (USA MARKET)
16 Pages
-
M - SM S&T MARINE CONDENSERS
2 Pages
-
L CONDENSERS
20 Pages
-
C CONDENSERS
20 Pages
-
MPE S&T EVAPORATORS
16 Pages
-
HPE S&T EVAPORATORS
24 Pages
-
HDE S&T EVAPORATORS
20 Pages
-
LPE S&T EVAPORATORS
12 Pages
-
LSE S&T EVAPORATORS
16 Pages
-
SSE S&T EVAPORATORS
16 Pages
-
GENERAL CATALOGUE
2 Pages
-
DRY COOLER RANGE 2022
2 Pages
-
Air-Radial-Cooler - ER - AR
28 Pages
-
LIQUID COOLERS GLV - PGLV
40 Pages
-
LIQUID COOLERS FVN - PFVN
60 Pages
-
REMOTE CONDENSERS CVN
36 Pages
-
REMOTE CONDENSERS CND
56 Pages
-
LIQUID COOLERS FND - PFND
72 Pages
-
REMOTE CONDENSERS HVL
20 Pages
-
REMOTE CONDENSERS CLV
24 Pages
-
LIQUID COOLERS FLV - PFLV
32 Pages
-
BRINE COOLERS A-AD
36 Pages
-
REMOTE CONDENSER CN
48 Pages
-
UNIT COOLERS E-EG-ED
44 Pages
-
LIQUID COOLERS FN - PFN
68 Pages
-
OIL BRAZED PLATES
2 Pages
-
BRAZED PLATES US
24 Pages
-
BRAZED PLATES
44 Pages