Specifications:
All liquid coolers feature finned coils made from copper pipes and aluminum fins with high-efficiency pyramidal corrugation. The frame is constructed from galvanized steel to prevent damage and ensure durability. The external frame is epoxy painted in RAL9016, and fan cowls are designed for optimal performance and noise reduction. Standard fan motors operate at 400V - 3F - 50Hz, with options for 60Hz. They include an external rotor with IP54 protection and are balanced both statically and dynamically. Capacities are tested according to ENV1048 standards at specific temperatures using a water/ethylene glycol mixture. Coils are tested with dry air and have a standard design pressure of 10 bar. Performance coefficients adjust for temperature differences and altitude. Options include various fan motor configurations, speed regulators, and additional protective features. The adiabatic system requires a minimum water pressure of 2.5 bar.
Overview: The document details technical specifications for liquid coolers in the FLV and PFLV series, including model configurations, capacities, air flow, power consumption, and dimensions.
Specifications:
  • Models: FLV and PFLV series with configurations like FLV808A3A and PFLV801A2AM.
  • Fan Numbers: 1 to 8 fans per model.
  • Capacity: Varies by model and fan configuration, measured at ∆T1 15K.
  • Air Flow: Varies by model, measured in cubic meters per hour (m3/h).
  • Power Consumption: Detailed in kW, varies by model.
  • Nominal Current: Provided in amperes (A), varies by model.
  • RPM and Sound Levels: Specified for each model.
Procedures and Standards:
  • Capacity Calculation: Based on ENV1048 standards.
  • Sound Measurement: According to EN13487 / ISO 3744 standards.
  • Dimensions and Weight: Standard dimensions and weights provided, excluding optional accessories.
Recommendations:
  • Dimensions are preliminary and should be confirmed with the technical department.
  • Contact Onda for specific drawings and weights if needed.
Key Data from Tables:
  • Model FLV808A3A: Capacity of 608.5 kW, air flow of 179650 m3/h, power consumption of 14.4 kW, and nominal current of 31.2 A.
  • Model PFLV801A2AM: Capacity of 60.1 kW, air flow of 23000 m3/h, power consumption of 1.8 kW, and nominal current of 3.9 A.
Conclusion: The document provides comprehensive technical data for selecting and configuring liquid coolers in the FLV and PFLV series, ensuring compatibility with specific operational requirements and standards.
Specifications and Dimensions:
Specifications for models FLV_PFLV26, FLV_PFLV27, and FLV_PFLV28 include dimensions and positioning options. Dimensions and lifting points are indicative and should be confirmed by the technical department.
Warranty Terms:
Onda S.p.A. offers an 18-month warranty from delivery, covering defects in materials and workmanship. Defects must be reported within 10 days of receipt or discovery. The warranty excludes defects from natural wear, unauthorized modifications, improper use, or non-compliance with specifications.
Exclusions and Limitations:
The warranty excludes defects from non-compliance with laws or regulations enacted after order confirmation. The client is responsible for compliance and indemnifies Onda S.p.A. against related claims. Onda S.p.A. is not liable for indirect or incidental damages.
Contact Information:
Contact details for Onda S.p.A. and its international branches are provided, including addresses and phone numbers for headquarters and plants in Italy.
See more

Catalog excerpts

LIQUID COOLERS FLV - PFLV-2

Liquid coolers FLV_PFLV

 Open the catalog to page 2
LIQUID COOLERS FLV - PFLV-3

Raffreddatori di liquido FLV_PFLV Advanced Heat Exchangers Heat Exchange Finned Coils Batterie di scambio termico _All finned coils of liquid coolers are produced with copper pipes and aluminium fins with high efficiency pyramidal corrugation _The frame of finned coils is produced in galvanized steel with thickness suitable to weight of heat exchanger. _All pipes are expanded on aluminium counter-endplates to avoid any contact between copper pipes and steel frame and therefore any possible pipe damage. _Tutte le batterie a pacco alettato dei Raffreddatori di liquido sono realizzate con tubi in...

 Open the catalog to page 3
LIQUID COOLERS FLV - PFLV-4

Liquid coolers FLV_PFLV Quick Selection / Selezione rapida Liquid cooler can be selected if you know cooling capacity and working conditions according La selezione del raffreddatore di liquido può essere effettuata conoscendo la potenza da to following scheme and parameters. smaltire richiesta e le condizioni di lavoro secondo lo schema e i parametri indicati di seguito. Ambient temperature coefficient K1 / Coefficiente temperatura ambiente K1 Tambient / T ambiente K1 0% ethylene glycol / K1 0% glicole etilenico K1 35% ethylene glycol / K1 35% glicole etilenico Fluid temperature / temperatura...

 Open the catalog to page 4
LIQUID COOLERS FLV - PFLV-5

Raffreddatori di liquido FLV_PFLV Advanced Heat Exchangers Option / Opzioni PLEASE CHECK PAGE 8 TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE CONSULTARE PAGINA 8 PER CONOSCERE LA DISPONIBILITÀ DELLE OPZIONI Cablaggio elettroventilatori Fans with wiring in terminal box Fans with wiring in electrical box including switches and thermal protection for each fan and general switch. Fans with wiring in electrical box including protection fuses for single fan. The EC fan control module ( code RE ) is supplied separatly, in this configuration the fans can be controlled qith one external 0-10V signal....

 Open the catalog to page 5
LIQUID COOLERS FLV - PFLV-6

Liquid coolers FLV_PFLV Option / Opzioni PLEASE CHECK PAGE __ TO KNOW THE AVAILABILITY OF THE OPTIONS CODE CODICE Kit supporti per flusso aria verticale Kit supports for vertical air flow The unit are standard always shipped and packed in vertical configuration with horizzontal air flow. In case of vertical air flow is necessary to add the option “SV” kit supports for vertical air flow. Is always necessary specify in the order the unit with correct air flow direction ( V = vertical air flow ; H = horizzontal air flow ) because the circuitation of the units is realized to be drainable in the specifical...

 Open the catalog to page 6
LIQUID COOLERS FLV - PFLV-7

Raffreddatori di liquido FLV_PFLV Advanced Heat Exchangers Adiabatic system / Sistemi adiabatici Nozzle dimension and quantity are selected to get the correct water flow and the best distribution on the finned block. Dimensione e numero di ugelli sono ottimizzati e calcolati per ottenere la corretta portata d’acqua e la miglior distribuzione possibile sul pacco alettato. La pressione minima dell’acqua richiesta è di 2,5 bar. Minimum required water pressure is 2,5 bar. Le elettrovalvole di carico e scarico vengono gestite dal controllo dei ventilatori (nel caso venga selezionato uno dei quadri...

 Open the catalog to page 7
LIQUID COOLERS FLV - PFLV-8

Liquid coolers FLV_PFLV The adiabatic system PD is supplied completely assembled and ready to be used. Il sistema adiabatico PD viene fornito completamente montato e pronto all’uso. The structure PD is integrated in the unit and constituted by a water distribution system completely openable, the plastic panels and the trays for water collection and discharge. La struttura PD è integrata nella macchina ed è composta da un sistema di distribuzione dell’acqua completamente ispezionabile, dai pannelli in materiale plastico, dalle vasche di raccolta e scarico acqua. The water distribution system is...

 Open the catalog to page 8
LIQUID COOLERS FLV - PFLV-9

Raffreddatori di liquido FLV_PFLV ORDER CODE CODICI DI ORDINAZIONE Advanced Heat Exchangers Fans connection / Collegamento ventilatori D=∆ Y= Number of poles / Numero di poli X = 6S M=6 L=8 Coil type / tipo batteria Number of fans / Numero di ventole ( 1÷8 ) Diameter of fans / Diametro ventilatori 80 = Ø 800mm 91 = Ø 910mm Type / Esecuzione FLV = V shape Single row fans - tubes Ø12mm Esecuzione a V Singola fila di ventole - tubi Ø12mm PFLV = V shape Single row fans - tubes Ø16mm Esecuzione a V Singola fila di ventole - tubi Ø16mm

 Open the catalog to page 9
LIQUID COOLERS FLV - PFLV-10

Fan number Numero ventilatori

 Open the catalog to page 10
LIQUID COOLERS FLV - PFLV-11

Advanced Heat Exchangers Fan number Numero ventilatori

 Open the catalog to page 11
LIQUID COOLERS FLV - PFLV-12

Fan number Numero ventilatori Notes / Note (a) Capacity calculation based on ENV1048 / Rese calcolate secondo ENV1048 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per disegni e dati specifici contattare Onda.

 Open the catalog to page 12
LIQUID COOLERS FLV - PFLV-13

13 Advanced Heat Exchangers Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico 2310

 Open the catalog to page 13
LIQUID COOLERS FLV - PFLV-14

Liquid coolers PFLV Fan number Numero ventilatori

 Open the catalog to page 14
LIQUID COOLERS FLV - PFLV-15

Raffreddatori di liquido PFLV Advanced Heat Exchangers Fan number Numero ventilatori

 Open the catalog to page 15
LIQUID COOLERS FLV - PFLV-16

Liquid coolers PFLV Fan number Numero ventilatori Notes / Note (a) Capacity calculation based on ENV1048 / Rese calcolate secondo ENV1048 (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori. Per disegni e dati specifici contattare Onda.

 Open the catalog to page 16
LIQUID COOLERS FLV - PFLV-17

Raffreddatori di liquido PFLV 17 Advanced Heat Exchangers Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico 2310

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.