Catalog excerpts
BRINE COOLERS
Open the catalog to page 1Cubic brine coolers A
Open the catalog to page 23 Advanced Heat Exchangers Heat Exchange Finned Coils Batterie di scambio termico _All finned coils of unit coolers are produced with copper pipes and aluminium fins with high efficiency pyramidal corrugation. _The frame of finned coils is produced in galvanized steel with thickness suitable to weight of heat exchanger. _All pipes are expanded on aluminium counter-endplates to avoid any contact between copper pipes and steel frame and therefore any possible pipe damage. _Endplate holes corresponding to header nipples are larger to avoid that vibrations and dilatations can damage pipes....
Open the catalog to page 3Cubic brine coolers A Onda cubic brine are designed and produced to be used in all most common applications of commercial and industrial refrigeration. High quality of materials and very high efficiency of fans with external rotor, used for all series, lead to get a product with extreme quality and reliability. Gli aerorefrigeratori cubici Onda sono progettati e realizzati per essere applicati in tutte le più comuni applicazioni della refrigerazione commerciale ed industriale. L’alta qualità dei materiali utilizzati e l’elevatissima efficienza dei ventilatori a rotore esterno, utilizzati su...
Open the catalog to page 45 Advanced Heat Exchangers Defrosting options / Accessori sbrinamento CODE CODICE Standard electrical defrosting Light electrical defrosting Fan ring heaters Drip tray electrical defrosting* Imbricated hot glycol defrosting Water defrosting *Option included in E and EL defrosting Sbrinamento elettrico standard Sbrinamento elettrico ridotto Resistenze circolari di sbrinamento boccagli Sbrinamento elettrico controvasca* Sbrinamento a glicole caldo embricato Sbrinamento ad acqua *Opzione inclusa negli sbrinamenti E ed EL Other options / Altri accessori CODE CODICE Fans wiring on terminal box...
Open the catalog to page 5Cubic brine coolers A ORDER CODE CODICI DI ORDINAZIONE Fans connection / Collegamento ventilatori D=∆ Y= Fin spacing / Passo alette 40 = 4mm 60 = 6mm 80 = 8mm 100 = 10mm Coil type / tipo batteria Number of fans / Numero di ventole (1, 5) Diameter of fans / Diametro ventilatori 50 = Ø 500mm 56 = Ø 560mm 63 = Ø 630mm 80 = Ø 800mm Type / Esecuzione A = Cubic brine coolers Aerorefrigeratori cubici AD = Dual discharge brine coolers Aerorefrigeratori biflusso
Open the catalog to page 67 Advanced Heat Exchangers Available Series / Modelli Disponibili ET Blast Freezer EC - AC Centrifugal air and unit coolers
Open the catalog to page 7Cubic brine coolers A Internal Volume Fins step Passo alette Volume interno Notes / Note (a) Capacity calculation with ΔT1=10 K, room temperature 0 °C / Rese calcolate con ΔT1=10 K, temperatura di cella 0 °C (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard execution and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori e opzioni....
Open the catalog to page 89 Advanced Heat Exchangers Fins step Passo alette Volume interno
Open the catalog to page 9Cubic brine coolers A Fans Ventilatori Defrosting Sbrinamento Dry weight Peso a Vuoto Fans Ventilatori Sound pressure level 5m (c) Pressione Sonora a 5m (c) Power Consumption (b) Potenza Assorbita (b) Nominal Current (b) Corrente Nominale (b) Speed Velocità (a) Capacity calculation with ΔT1=10 K, room temperature 0 °C / Rese calcolate con ΔT1=10 K, temperatura di cella 0 °C (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 Dimension and weight refer to the standard...
Open the catalog to page 1011 Advanced Heat Exchangers Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. / Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico REV 1.1 - 10/201
Open the catalog to page 11Cubic brine coolers A Internal Volume Fins step Passo alette Volume interno Notes / Note (a) Capacity calculation with ΔT1=10 K, room temperature 0 °C / Rese calcolate con ΔT1=10 K, temperatura di cella 0 °C (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard execution and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori e opzioni....
Open the catalog to page 1213 Advanced Heat Exchangers Fins step Passo alette Volume interno
Open the catalog to page 13Cubic brine coolers A Fans Ventilatori Defrosting Sbrinamento Dry weight Peso a Vuoto Fans Ventilatori Sound pressure level 5m (c) Pressione Sonora a 5m (c) Power Consumption (b) Potenza Assorbita (b) Nominal Current (b) Corrente Nominale (b) Speed Velocità (a) Capacity calculation with ΔT1=10 K, room temperature 0 °C / Rese calcolate con ΔT1=10 K, temperatura di cella 0 °C (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 Dimension and weight refer to the standard...
Open the catalog to page 1415 Advanced Heat Exchangers Notes The dimensions of above drawing are only preliminary and must be always reconfirmed by our Tech. Dept. / Note: Le quote d’ingombro sono indicative e vanno sempre confermate dal nostro ufficio tecnico REV 1.1 - 10/201
Open the catalog to page 15Cubic brine coolers A Internal Volume Fins step Passo alette Volume interno Notes / Note (a) Capacity calculation with ΔT1=10 K, room temperature 0 °C / Rese calcolate con ΔT1=10 K, temperatura di cella 0 °C (b) Nominal data / Dati nominal (c) According EN13487 / ISO 3744 / In accordo EN13487 / ISO 3744 (d) Diameter valid for CE10 version / Diametri validi per versione CE10 (e) Dimension and weight refer to the standard execution and don’t include any option. Contact Onda for specifical drawing and weight Dimensioni e peso sono riferiti all’esecuzione standard priva di accessori e opzioni....
Open the catalog to page 16All Onda catalogs and technical brochures
-
PLATE & FRAME (US MARKET)
24 Pages
-
PLATE & FRAME
24 Pages
-
MARINE CONDENSER
2 Pages
-
CRW Condensers
16 Pages
-
HYBRID FILM EVAPORATOR
2 Pages
-
P PEG S&T EVAPORATORS
5 Pages
-
OVS SEPARATORS GEN.2
12 Pages
-
RL & RL-V LIQUID RECEIVERS
12 Pages
-
OIL COOLER
2 Pages
-
LVC CONDENSERS (USA MARKET)
12 Pages
-
FLS-FLT S&T EVAPORATORI
2 Pages
-
B CONDENSERS (EUROPE MARKET)
16 Pages
-
B CONDENSERS (USA MARKET)
16 Pages
-
M - SM S&T MARINE CONDENSERS
2 Pages
-
L CONDENSERS
20 Pages
-
C CONDENSERS
20 Pages
-
MPE S&T EVAPORATORS
16 Pages
-
HPE S&T EVAPORATORS
24 Pages
-
HDE S&T EVAPORATORS
20 Pages
-
LPE S&T EVAPORATORS
12 Pages
-
LSE S&T EVAPORATORS
16 Pages
-
SSE S&T EVAPORATORS
16 Pages
-
GENERAL CATALOGUE
2 Pages
-
DRY COOLER RANGE 2022
2 Pages
-
Air-Radial-Cooler - ER - AR
28 Pages
-
LIQUID COOLERS GLV - PGLV
40 Pages
-
LIQUID COOLERS FVN - PFVN
60 Pages
-
REMOTE CONDENSERS CVN
36 Pages
-
REMOTE CONDENSERS CND
56 Pages
-
LIQUID COOLERS FND - PFND
72 Pages
-
REMOTE CONDENSERS HVL
20 Pages
-
LIQUID COOLERS MVL - PMVL
28 Pages
-
REMOTE CONDENSERS CLV
24 Pages
-
LIQUID COOLERS FLV - PFLV
32 Pages
-
REMOTE CONDENSER CN
48 Pages
-
UNIT COOLERS E-EG-ED
44 Pages
-
LIQUID COOLERS FN - PFN
68 Pages
-
OIL BRAZED PLATES
2 Pages
-
BRAZED PLATES US
24 Pages
-
BRAZED PLATES
44 Pages