Catalog excerpts

Switch Mode Power Supply S8VK-G (15/30/60/120/240/480-W Models) Reliable and Easy Operation-Worldwide Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market • Universal input for worldwide applications: 100 to 240 VAC (85 to 264 VAC) • DC input can be available: 90 to 350 VDC • Possible for 2 phases input usage. • Wide operation temperature range: –40 to 70 °C • Power Boost function at 120% • Safety standards: UL508/60950-1, CSA C22.2 No. 107.1/60950-1 EN50178 (= VDE0160), EN60950-1 (= VDE0805). Lloyd’s standards*, EN60204-1 PELV Safety of Power Transformers: EN61558-2-16 • 15-W,30-W, and 60-W models conform to UL Class 2 output Standards • EMS: EN 61204-3 EMI: EN61204-3 Class B • Three years Warranty * Scheduled to obtain certification in June, 2013. ! Refer to Safety Precautions for All Power Supplies and Safety Precautions on page.
Open the catalog to page 1
Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. 1. Input voltage types G: Single phase Ordering Information Note: For details on normal stock models, contact your nearest OMRON representative. Power ratings Input voltage Output Voltage Output current Boost Current Model number
Open the catalog to page 2
Specifications Ratings, Characteristics, and Functions Power ratings Item Efficiency (Typical) Current (Typical) Power factor (Typical) Harmonic current emissions Leakage current (Typical) Inrush current (Typical) *2 Voltage adjustment range *3 –10% to 15% (with V.ADJ) (guaranteed) Input variation influence Load variation Influence (Rated Input voltage) Output Output voltage Temperature variation influence Start up time (Typical) *2 Hold time (Typical) *2 Overload protection *2 Overvoltage protection *2 Additional Power Boost functions Parallel operation 121% to 160% of rated load current...
Open the catalog to page 3
Power ratings Item Efficiency (Typical) Current (Typical) Power factor (Typical) Output voltage Harmonic current emissions Leakage current (Typical) Inrush current (Typical) *2 Voltage adjustment range *3 –10% to 15% (with V.ADJ) (guaranteed) Input variation influence Load variation Influence (Rated Input voltage) Output 0.5% max. (at 85 to 264 VAC input, 100% load) 2.0% max. (12 V), 1.5% max. (24 V), at 0% to 100% load Temperature variation influence Start up time (Typical) *2 Hold time (Typical) *2 Overload protection *2 Additional Overvoltage protection *2 functions Power Boost 121% to...
Open the catalog to page 4
Power ratings Item Efficiency (Typical) Current (Typical) Power factor (Typical) Harmonic current emissions Leakage current (Typical) Inrush current (Typical) *2 Voltage adjustment range *3 –10% to 15% (with V.ADJ) (guaranteed) Input variation influence Load variation Influence (Rated Input voltage) Output Output voltage Temperature variation influence Start up time (Typical) *2 Hold time (Typical) *2 121% to 160% of rated load current (130% typ value) Additional Power Boost functions Parallel operation 120% of rated current (Refer to Engineering Data) Yes (Refer to Engineering Data) Series...
Open the catalog to page 5
Connections Block Diagrams S8VK-G015@@ (15 W) Inrush Smoothing current circuit protection Rectifier/ smoothing circuit Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Noise filter Inrush Smoothing current protection circuit Drive control circuit Rectifier/ smoothing circuit Overcurrent circuit −V Current detection circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler Noise filter Inrush Smoothing current protection circuit Drive control circuit Rectifier/ smoothing circuit...
Open the catalog to page 6
Noise filter Harmonic current Inrush current Smoothing suppression circuit protection circuit (Power factor improvement) circuit Rectifier/smoothing circuit Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Noise filter Inrush current Harmonic current Smoothing suppression circuit protection circuit (Power factor improvement) Rectifier/smoothing circuit Drive control circuit Overcurrent circuit Current detection circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Noise filter AC (N) Inrush...
Open the catalog to page 7
Construction and Nomenclature Nomenclature 15-W Models Name Input terminals (L), (N) Protective Earth terminal (PE) DC Output terminals (V), (+V) Output indicator (DC ON: Green) Output voltage adjuster (V.ADJ) Function Connect the input lines to these terminals. *1 Connect the ground line to this terminal. *2 Connect the load lines to these terminals. Lights while a direct current (DC) output is ON. Use to adjust the voltage. *1. The fuse is located on the (L) side. It is not user-replaceable. For a DC input, connect the positive voltage to the L terminal. *2. This is the protective earth...
Open the catalog to page 8
Load ratio (%) Load ratio (%) Note: 1. At less than 90 VAC, the derating is 2.5%/V 2. For a DC power input, reduce the load given in the above derating curve by multiplying the following coefficients. S8VK-G015@@: 1.0 S8VK-G030@@: 0.9 S8VK-G240@@: 0.8 3. See “–40°C Operation Guarantee Condition” Note: 1. At less than 90 VAC, the derating is 2.5%/V 2. For a DC power input, reduce the load given in the above derating curve by multiplying the following coefficients. S8VK-G12024: 0.9 3. See “–40°C Operation Guarantee Condition” A. Standard mounting 60°C and over: the derating is 3.5%/°C B....
Open the catalog to page 9
Power Boost Function (A) Standard (Vertical) mounting For All Models Power Boost is a function that can output the temporary repeated boost current larger than the rated current. However, it should meet the following four Boost current conditions. 1. Time that the boost current flows: t1 2. The maximum value of the boost current: lp 3. The average output current: lave 4. The time ratio of the boost current flow: Duty Note: Boost current conditions (C) Side mountining only for 15 W • t1 ≤ 10 s • Ip ≤ Rated boost current • lave ≤ Rated current Duty= Overload Protection The load and the power...
Open the catalog to page 10All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages