Switch Mode Power Supply S8JC-Z / S8JC-ZS S8JC-ZS, newly released Power Supply with CE marking, additional models for economical Power Supply, S8JC-Z series. S8JC-Z/S8JC-ZS is our best standard power supply for • material cost reduction • export machines, required safety standard • time saving for installation by DIN-rail mounting Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. 1. Conformed standards None: no standard S: CE (EN50178) 5. Configuration/mounting None: Bottom-mounting D: DIN Rail-mounting 6. Input Voltage None/AC2: 200 to 240 VAC Line-up & Feature S8JC-Z series (15/35/50/100/150/350-W models) Voltage For More application ! More Output Voltage Specifications from 5 V to 48 V Various power rating range from 15 W to 350 W S8JC-ZS series (15/35/50/100/150-W models) Voltage For More reliability ! Conformed to CE marking Expanded operating temperature: 20C to +70C Improved Dielectric strength
Open the catalog to page 1Ordering Information List of Models in S8JC-Z Series Note: For details on normal stock models, contact your nearest OMRON representative. Conformed standard Input voltage Power ratings Covered Power Supplies Output voltage Output current
Open the catalog to page 2S8JC-Z List of Models in S8JC-ZS Series Note: For details on normal stock models, contact your nearest OMRON representative. Comformed standard Input voltage Power ratings Output current Covered Power Supplies
Open the catalog to page 3Ratings, Characteristics, and Functions 15-/35-W Models Power ratings Item Series name Certification Output voltage (VDC) Voltage adjustment range (typical) Ripple (typical) Startup time (typical) Output current Hold time (typical) Efficiency (typical) Inrush current (for a cold start at 25C) (typical) Overload protection 105% of rated load current, voltage drop, intermittent, automatic reset 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Parallel operation Series operation Ambient operating temperature *Refer to the derating curve in Engineering...
Open the catalog to page 4S8JC-Z 50-/100-W Models Power ratings Item Series name Certification Output voltage (VDC) Voltage adjustment range (typical) Ripple (typical) Startup time (typical) Hold time (typical) Output current Efficiency (typical) Current (typical) Leakage current Inrush current (for a cold start at 25C) (typical) Overload protection 105% of rated load current, voltage drop, intermittent, automatic reset 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Parallel operation Series operation Ambient operating temperature *Refer to the derating curve in Engineering...
Open the catalog to page 5S8JC-Z 150-/350-W Models Power ratings Item Series name Certification Output voltage (VDC) Voltage adjustment range (typical) Ripple (typical) Startup time (typical) Hold time (typical) Output current Efficiency (typical) Current (typical) Leakage current Inrush current (for a cold start at 25C) (typical) Overload protection 105% of rated load current, voltage drop, intermittent, automatic reset 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Parallel operation Series operation Ambient operating temperature *Refer to the derating curve in Engineering...
Open the catalog to page 6Noise filter Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Noise filter AC (N) Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Noise filter AC (N) Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Noise filter AC (N) Inrush...
Open the catalog to page 7Engineering Data Derating Curves for S8JC-ZS Load rate (%) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading “A” in the above graph). 2. If there is a derating problem, use forced air-cooling. Terminal Arrangement 15-/35-/50-W Models Note: The S8JC-Z05024C is shown above. Note: The S8JC-Z35005C is shown above. Note: 1. The S8JC-Z10024C is shown above. 2. The rated current for output terminals is 25 A per terminal. Be sure to use multiple terminals simultaneously for current that...
Open the catalog to page 8Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting Note: The screws must not protrude more than 2 mm inside the Power Supply when screw holes provided on the chassis are used. If the dimensions are not correct, the Power Supply may be damaged. S8JC-ZS035@@C-AC2 (35 W) S8JC-ZS050@@C-AC2 (50 W) Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting
Open the catalog to page 9Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting Three, M3
Open the catalog to page 10Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting
Open the catalog to page 11Panel mounting holes dimensions (3) Surface screw mounting Side Mounting Bottom Mounting Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting
Open the catalog to page 12Safety Precautions Refer to Safety Precautions for All Power Supplies. Precautions for Safe Use Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. Connect the ground completely. Electric shock or malfunction may occur if the ground is not connected completely. The service life of the fan...
Open the catalog to page 158 Pages
11 Pages
5 Pages
104 Pages
4 Pages
20 Pages
20 Pages
28 Pages
24 Pages
9 Pages
49 Pages
28 Pages
10 Pages
16 Pages
5 Pages
3 Pages
9 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
15 Pages
13 Pages
6 Pages
25 Pages
29 Pages
4 Pages
3 Pages
5 Pages
68 Pages
68 Pages
35 Pages
16 Pages
5 Pages
8 Pages
8 Pages
6 Pages
14 Pages
11 Pages
7 Pages
9 Pages
7 Pages
7 Pages
9 Pages
12 Pages
17 Pages
14 Pages
6 Pages
9 Pages
10 Pages
12 Pages
9 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
8 Pages
5 Pages
5 Pages
5 Pages
8 Pages
3 Pages
11 Pages
21 Pages
9 Pages
14 Pages
26 Pages
6 Pages
59 Pages
410 Pages
6 Pages
8 Pages
12 Pages
12 Pages
40 Pages
6 Pages
42 Pages
16 Pages
32 Pages
24 Pages
2 Pages
54 Pages
28 Pages
108 Pages
24 Pages
100 Pages
12 Pages
2 Pages
18 Pages
31 Pages
28 Pages
24 Pages
22 Pages
12 Pages
57 Pages
30 Pages
16 Pages
7 Pages
4 Pages
28 Pages
32 Pages
24 Pages
17 Pages
16 Pages
24 Pages
36 Pages
8 Pages
24 Pages
24 Pages
38 Pages
12 Pages
55 Pages
20 Pages