NX-series Safety Control Units Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. • EN ISO13849-1 (PLe/Safety Category4), IEC 61508 (SIL3) certified. • One connection using Safety over EtherCAT (FSoE) * protocol enables flexible configuration by mixing the Safety Units with standard NX I/O. • Hardware and safety circuits can be configured using the Sysmac Studio (Ver. 1.07) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. * Safety over EtherCAT (FSoE): The open protocol Safety over EtherCAT (abbreviated with FSoE "FailSafe over EtherCAT") defines a safety related communication layer for EtherCAT. Safety over EtherCAT meets the requirements of IEC 61508 SIL 3 and enables the transfer of safe and standard information on the same communication system without limitations with regard to transfer speed and cycle time. Features • Integrated safety into machine automation possible by connecting with the NX-series EtherCAT Coupler. • The Safety CPU Unit controls up to 128 Safety I/O Units. • 4 or 8 points per Safety Input Unit. The 4-point Safety Input Unit can be directly connected with OMRON Non-contact Switches and Singlebeam Sensors. • 2 or 4 points per Safety Output Unit. The 2-point Safety Output Unit is characterized by large output breaking current of 2.0 A. • The Safety Units can be freely allocated in any combination with standard NX I/O. • Compliant with IEC61131-3 • Safety programs can be standardized and reused efficiently by using POUs for design and operation. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. Safety over EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. ODVA, CIPTM, CompoNetTM, DeviceNetTM, EtherNet/IPTM, and CIP SafetyTM are trademarks of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their res
Open the catalog to page 1
System Configuration EtherCAT System Sysmac Studio Support Software EtherCAT master* NJ/NX-series CPU Unit Connection to peripheral USB port or built-in EtherNet/IP port on NJ-series CPU Unit Built-in EtherCAT port Sysmac Studio Support Software ●EtherCAT Slave Terminal Communications cable Ethernet cables Peripheral USB port. NX Series EtherCAT Coupler Unit NX-ECC201/ECC202 Safety CPU Unit NX-SL3300 NX-SL3500 Safety Input Unit NX-SID800 Connection to peripheral USB port on EtherCAT Coupler Unit NX Series EtherCAT Coupler Unit NX-ECC201 Safety Output Unit NX-SOD400 Safety Input Unit...
Open the catalog to page 2
NX-SL/SI/SO Stand-alone System EtherNet/IP master CJ-series CPU Unit or master from another manufacturer Peripheral USB port EtherNet/IP port Communications cable Ethernet cables Sysmac Studio Support Software NX-series EtherNet/IP Coupler Unit NX-EIC202 Safety CPU Unit NX-SL3300 Safety Input Unit NX-SID800/SIH400 Safety Output Unit NX-SOD400/SOH200 End Cover NX Units * Connection to peripheral USB port on EtherNet/IP Coupler Unit * Refer to NX-series EtherNet/IPTM Coupler Unit Datasheet for the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit.
Open the catalog to page 3
Ordering Information Safety CPU Unit
Open the catalog to page 4
NX-series Communications Coupler Units Product name Note: For details, refer to your local OMRON website. *1 One End Cover NX-END01 is provided with the NX-series Communications Coupler Units. *2 This depends on the specifications of the EtherCAT master. For example, the values are as follows when the EtherCAT Coupler Unit is connected to the built-in EtherCAT port on an NJ5-series CPU Unit: 500 ps, 1,000 ps, 2,000 ps, and 4,000 ps. Refer to the NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (Cat. No. W505) for the specifications of the built-in EtherCAT ports on NJ/NX-series...
Open the catalog to page 5
NX-series Safety Control Units NX-SL3/SI/SO
Open the catalog to page 6
Specifications of Individual Units
Open the catalog to page 7
Safety Input Units NX-SIH400/SID800 Unit name Free-Run refreshing Screwless clamping terminal block (8 terminals) 1.2 V max. (Between IOV and all output terminals) Photocoupler isolation 20 MQ min. between isolated circuits (at 100 VDC) Power supplied from the NX bus Terminal block Si0 to Si3: Safety input terminals T0 and T1: Test output terminals Refer to User's manual (Cat.No.Z930) for details. Safety Input Unit NX-SID800 NX-SL/SI/SO Screwless clamping terminal block (16 terminals) 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. Connected to a CPU Unit or a...
Open the catalog to page 8
Unit name 2.0 A/point 4.0 A/Unit at 40°C 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature Free-Run refreshing Screwless clamping terminal block (8 terminals) 1.2 V max. (Between IOV and all output terminals) 2 V max. (Between IOG and all output terminals) Photocoupler isolation 20 MQ min. between isolated circuits (at 100 VDC) Power supplied from the NX bus So0 and So1: Safety output terminals IOG: I/O power supply 0 V Refer to User's manual (Cat.No.Z930) for details. Safety Output Unit 510 VAC for 1 min between isolated circuits,...
Open the catalog to page 9
Unit name Model Safety Output Unit NX- SOH200 Installation orientation: • Connected to a CPU Unit or a Communication Control Unit Possible in the upright installation orientation. • Connected to a Communications Coupler Unit 6 possible orientations Restrictions: For upright installation, the ambient temperature is restricted as shown below depending on the total Unit load current. Installation orientation: • Connected to a CPU Unit or a Communication Control Unit Possible in the upright installation orientation. • Connected to a Communications Coupler Unit 6 possible orientations...
Open the catalog to page 10
Function Specifications
Open the catalog to page 11
Note: Supported only by the Sysmac Studio version 1.07 or higher. *1. Supported only by the Sysmac Studio version 1.24 or higher. *2. Supported if the EtherNet/IP Coupler is selected with Sysmac Studio version 1.11 or higher. *3. Supported only by the Sysmac Studio version 1.12 or higher. *4. Supported only by the Sysmac Studio version 1.17 or higher. *5. Supported only by the Sysmac Studio version 1.08 or higher. *6. Supported only by the Sysmac Studio version 1.10 or higher. *7. Supported only by the Sysmac Studio...
Open the catalog to page 12All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages