
Catalog excerpts

Better SYSMAC Compatibility and Easier-to-use Support Software
Open the catalog to page 1
Providing What's Needed in Programmable Terminals The Simple Design and Easy Operation That Users Need. Reduced TCO* throughout Onsite System Construction and Maintenance. To keep in pace with the progress of information technology on production sites, more advanced and more diversified functions are continuously required from operator interfaces. OMRON continuously researches the use of operator interfaces at all stages of application. OMRON scrutinizes system compatibility, design efficiency, operability, and maintenance, and helps reduce the TCO for the introduction, maintenance, and...
Open the catalog to page 2
A Lineup of Models with Versatile Display Features and Easy Operation The lineup includes one large, two medium-size, and one small PT with different display devices. The functions and operability of all models are unified, making replacement with another model easy. Screen data from previous models can be used for all large, medium-size, and small PT models in the series. Effective display area Number of dots (resolution) Max. number of touch switches External interface Applicable standards Host Link Memory Link Mitsubishi A-Series (Computer Link Unit) Simplified Chinese Traditional...
Open the catalog to page 3
Improved SYSMAC Compatibility for Easier System Construction Programming Console and Device Monitor Functions [Device Monitor] The device monitor function makes it possible to read and write I/O memory data and display consecutive sections of PLC data areas. This function greatly improves the efficiency of PLC setup work, including set value input into the Special I/O Units and checks on the settings. Data can be read from I/O memory from a user-created screen to enable application on maintenance screens for monitoring. [Programming Console Functions] C-series and CS/CJ-series ladder...
Open the catalog to page 4
Full-area Access to SYSMAC CS1/CJ1-series PLCs over High-speed NT Link Connect to SYSMAC CS1/CJ1-series PLC over High-speed NT Link The industry's highest serial communications speed. Up to eight NT631/NT31/NT20 Units can be connected to a single port. Extends to a maximum of 500 m. Essentially the same performance is achieved for NT Links with eight PTs as for an NT Link with a single PT (for refreshing numeric displays). OMRON Data Comparison Response Speed for Communications with Single PT Connected Host Link High-speed NT Link SYSMAC CS1/CJ1-series (-V1) PLC Response Speed for...
Open the catalog to page 5
Easier Screen Creation and Better Design Efficiency with Improved Support Software Unified Screen Creation Environment with the NTST NT Support Software Windows Look and Feel environment ensures easy operation, allowing anyone to create screens quickly and easily. The enhanced ON/OFF simulation function of the NT631/NT31/NT20 and easy application of existing screen data accelerate product development and designing. Edit screen The arrow keys on the keyboard are used to move objects dot by dot. Displays object and cursor coordinates. The window being manipulated can be displayed or not...
Open the catalog to page 6
Complete Functions in NT Support Software Error Log Viewer Double-click the error message to track down the error on the screen. All PLC addresses and I/O comments can be managed together. Addresses that have been allocated are automatically registered in the I/O comment table. Object Alignment Filter The filter function makes editing easier by displaying only the objects you select for modification. Online Help Objects can be top-, bottom-, left-, right-, or center-aligned automatically. Search Function Click the Help icon whenever you are not sure how to proceed. The information you need...
Open the catalog to page 7
Easier, More Efficient On-site Maintenance. Increased Backlight Life for Maintenance-free Operation The Backlight Module has been redesigned to eliminate the need to replace the Backlight and enable maintenance-free operation for up to 50,000 hours. System Program Transfer By transferring a new system program, functions and performance can be updated without changing hardware. The following system programs are provided. OMRON (Memory Link) and Mitsubishi versions for NT31/631 OMRON, Mitsubishi, and Memory Link versions for NT30/620 OMRON, Mitsubishi, and Memory Link (RS-232C) versions for...
Open the catalog to page 8
Special Utility to Transfer Screen Data It is possible for anyone to easily transfer screens by using a special software application instead of the NT Support Software. The software application can be set up separately. The NT20 system program can be transferred using the transfer utility provided with NT Support Software version 4.8 or higher. Change the setting to "NT20S" if using the transfer utility provided with Support Software version 4.0 or lower. Supports Wide Variety of Language Input European and English languages are supported. (The English version of the NT Support Software is...
Open the catalog to page 9
Wide Range of Communications Interfaces NT631 Series Expansion interface connector Flat, Thin-profile Model Only 54 mm Thick All models have flat, smooth surfaces and are only 54 mm thick, which is ideal for space-saving designs built into equipment. Equivalent to the IP65 Oil-proof Standard Ensures a High Degree of Resistance to the Environment. The NT631/NT31 has a flush-surface construction and is highly resistive to severe operating environments. The front panel conforms to IP65F oil-proof type. IP: International Protection 6 : Resistant to dust (protected from solid objects) 5 :...
Open the catalog to page 10
Display Specifications General Specifications Model Item Rated power supply voltage Allowable power supply voltage range Character displays (fixed display) Power consumption Graphic displays 65,535 per screen (including marks) Character string displays Up to 256 per screen (40 bytes (40 characters) per string) Numerical displays 256 per screen, max. 10-digit display (2 words) Up to 50 per screen, percentage display and sign display are possible Ambient operating environment Analogue meter Up to 50 per screen, percentage display and sign display are possible. Noise immunity Conforms to IEC...
Open the catalog to page 11All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages