Catalog excerpts

General-purpose Relays New Super MK Relays. Models with Latching Lever Added to the Series. • Same mounting and internal wiring as the previous Super MK Relays • Built-in mechanical indicator enables checking contact operation. • Two modes can be used to check circuits for models with latching lever. • Nameplate provided on models with latching lever. • All materials are RoHS compliant. • UL and IEC (TÜV) certification. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Models with Latching Lever Operating Method for Latching Lever Operation indicator * Relay in Normal Operation Slide the latching lever to the first position, then press the yellow button with an insulated tool to operate the contact. Slide the latching lever to the second position. (The contact is now in the locked position.) Mechanical indicator Latching lever DC: Blue AC: Red Yellow button * The operation indicator is built in only on specified models. Example of Applications of Models with Latching Levers Operation checks in relay sequence circuits Model Number Structure Model Number Legend MKS@@@@@-@-@ 1 2 3 4 5 5. Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only) 6. Surge Absorption Blank: Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only) 3. Mechanical Indicator/Test Button Blank: Mechanical indicator I: Mechanical indicator and lockable test button 4. LED Indicator Blank: Standard N: LED indicator 7. Internal Connections Blank: Standard 2 or 5: Non-standard connections (Refer to “Terminal Arrangement and Internal Connection (Bottom View)”.) 8. Rated Voltage (Refer to “Coil Ratings”.)
Open the catalog to page 1
Ordering Information List of Models Type Contact form Internal connections (See note 3.) With mechanical indicator With mechanical indicator Coil ratings and lockable test button DPDT Models with LED Indicator (See note 2.) Standard Models Standard Standard DPDT Models with Varistor 3PDT Standard Standard DPDT Models with LED Indicator and Varistor Standard Standard Models with LED Indicator and Diode DPDT Models with Diode (See note 2.) Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS3P...
Open the catalog to page 2
Specifications Ratings Coil Ratings Rated current Rated voltage Coil resistance Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz 110% of rated voltage 30% min. of rated voltage at 60 Hz 25% min. of rated voltage at 50 Hz Power consumption Must release voltage Must operate voltage 125 V 10.8 mA 11,576 Ω The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and ±15% for DC coil resistance. Performance characteristic data are measured at a coil temperature of 23°C. The maximum voltage is one that is applicable...
Open the catalog to page 3
MK-S Characteristics Contact resistance 100 mΩ max. AC: 20 ms max. Operate time DC: 30 ms max. Release time 20 ms max. (40 ms max. for built-in Diode Relays) Mechanical: 18,000 operations/h Max. operating frequency Electrical: 1,800 operations/h (under rated load) Insulation resistance 100 MΩ min. (at 500 VDC) 2,500 VAC 50/60 Hz for 1 min between coil and contacts Dielectric strength 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity 2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity...
Open the catalog to page 4
Models without Latching Lever Models with Latching Lever Sockets See below for Socket dimensions. Socket Maximum carry current Surface-mounting Socket (for track or screw mounting) Finger-protection models 10 A Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with “-E” at the end of the model number. When using the PF083A and PF113A, be sure not to exceed the Socket's maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round terminals cannot be used for finger-protection models. Use Y-shaped terminals. PF113A-E (Conforming to EN 50022)...
Open the catalog to page 5
Terminal Arrangement Mounting Holes Mounting Holes Hold-down Clips Mounting Tracks * This dimension applies to the PFP-50N Mounting Track. * A total of twelve 25 × 4.5 elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm. Mounting Height with Sockets Surface-mounting Sockets Three poles Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
Open the catalog to page 6
Terminal Arrangement and Internal Connection (Bottom View) Standard Models (AC/DC Coil) Models with Models with Diode Standard Polarity) Models with Reverse Polarity) Standard Models Standard Polarity) Models with Diode Reverse Polarity) Models with
Open the catalog to page 7
Models with Varistor (AC Coil) Models with LED indicator and Varistor (AC Coil) Safety Precautions Refer to Safety Precautions for All Relays. Safety Precautions for Correct Use Installation Mount the MK-S with the marking at the bottom. Handling Check the coil polarity of models with built-in operation indicator (DC operation coil) and wire them correctly . Test Button Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other...
Open the catalog to page 8
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...
Open the catalog to page 9All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages