omRonThree-phase Asymmetry and Phase-sequence Phase-loss RelayK8DS-PA Ideal for 3-phase Voltage Asymmetry Monitoring for Industrial Facilities and Equipment. • Greater resistance to inverter noise. new • Monitor voltage asymmetry, phase sequence, and phase loss in three-phase three-wire circuits with one unit. • One SPDT output relay, 5 A at 250 VAC (resistive load). •World-wide power specifications supported by one unit. (Set with a rotary switch.) •Relay status can be monitored using LED indicator. A Refer to Safety Precautions on page 8. Refer to page 7 for commonly asked questions. Ordering Information List of Models Note: The input range is set with a rotary switch. * The power supply voltage is the same as the rated input voltage.

Open the catalog to page 1
K8DS-PA - 3

Specifications Input frequency •Relationship of Mounting Distance between K8DS-PA Relays and Ambient Temperature (Reference Values) The following diagram shows the relationship between the mounting distances and the ambient temperature. If the relay is used with an ambient temperature that exceeds these values, the temperature of the K8DS may rise and shorten the life of the internal components. DIN Track Distance between products: d

Open the catalog to page 3
K8DS-PA - 4

Terminal Diagram Relay Output Note: Use the recommended ferrules if you use twisted wires. Wiring Example •Voltage Asymmetry and Phase Sequence/Phase Loss Operation Diagram Alarm indicator Contacts Flashing LHHL Phase Loss Operation i Operation Table Note: 1. The K8DS-PAQ output contacts are normally operative. 2. The power ON lock prevents unnecessary alarms from being generated during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss is detected when any...

Open the catalog to page 4
K8DS-PA - 5

NomenclatureFront •Indicators Item * This indicator uses the input across L2 and L3 as the internal power supply. It will not light unless there is an input across L2 and L3. •Setting Knobs Item Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part inserted into the terminal must be 8 mm or less to maintain dielectric strength after connection. For 2.5 mm2 or For ferrules with smaller solid wires an insulation sleeve. Recommended ferrules Phoenix Contact • Al 1,5-8BK (for...

Open the catalog to page 5
K8DS-PA - 6

K8DS-PA Setting Methods ●Asymmetry The asymmetry rate is set using the asymmetry rate knob (ASY.) The setting range is 2% to 22% of the rated input. Turn the knob while there is an input to the input terminals until the alarm indicator flashes (when the set value and the input have reached the same level.) Use this as a guide to make the setting. The rated input depends on the model and the rotary switch setting. Example: K8DS-PA1 with Rotary Switch Set to 200 V The rated input is 200 VAC, so the setting range is 4 to 44 V. If the setting (ASY. knob) is at 10%, the asymmetry operation...

Open the catalog to page 6
K8DS-PA - 7

Checking Operation With the rated input voltage applied, gradually change one of the phase-to-phase voltages. The Relay will operate when the difference between the highest and lowest voltage phases reaches or exceeds the asymmetry operating value. Asymmetry operating value = Rated input voltage × Asymmetry set value (%) Phase Sequence Operation Switch the wiring, as shown by the dotted lines in connection diagram 1, to reverse the phase sequence and check that the K8DS operates. Phase Loss Operation Create a phase loss for any input phase and check that the K8DS operates. Example:...

Open the catalog to page 7
K8DS-PA - 8

Warning Indications K8DS-PA Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Electrical shock may occasionally cause serious injury. Confirm that the input voltage is OFF before starting any wiring work and wire all connections correctly. Electrical shock may cause minor injury. Do not touch terminals while electricity is being supplied. There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to...

Open the catalog to page 8
K8DS-PA - 9

Precautions for Safe Use 1. Do not use or store the product in the following locations. • Locations subject to water or oil • Outdoor locations or under direct sunlight • Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) • Locations subject to rapid temperature changes • Locations prone to icing and dew condensation • Locations subject to excessive vibration or shock • Locations subject to wind and rain • Locations subject to static electricity and noise • Habitats of insects or small animals 2. Use and store the product in a location where the...

Open the catalog to page 9
K8DS-PA - 10

K8DS-PA Operating the Setting Knobs and Rotary Switch • Use a screwdriver to adjust the setting knobs and rotary switch. The knobs have a stopper that prevents them from turning beyond the full right or left position. Do not force a knob beyond these points. Setting knob

Open the catalog to page 10
K8DS-PA - 11

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...

Open the catalog to page 11
K8DS-PA - 12

Industrial Automation Company www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120,...

Open the catalog to page 12

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. G9SA-300-SC

    9 Pages

  16. K8AK-AS

    12 Pages

  17. K8AK-AW

    16 Pages

  18. K8AK-VS

    12 Pages

  19. K8AK-VW

    12 Pages

  20. K8AK-PH

    12 Pages

  21. K8DS-PH

    12 Pages

  22. K8AK-PM

    16 Pages

  23. K8DS-PM

    12 Pages

  24. K8AK-PA

    12 Pages

  25. K8AK-PW

    12 Pages

  26. K8DS-PU

    12 Pages

  27. K8DS-PZ

    12 Pages

  28. K8AK-TS/PT

    12 Pages

  29. K8AK-LS

    12 Pages

  30. K8AK-TH

    12 Pages

  31. K2CM

    16 Pages

  32. SE

    15 Pages

  33. SAO

    13 Pages

  34. APR-S

    6 Pages

  35. XS5

    25 Pages

  36. XS2

    29 Pages

  37. F92A

    4 Pages

  38. GLS

    3 Pages

  39. TL-L

    5 Pages

  40. V680 series

    68 Pages

  41. V680S Series

    68 Pages

  42. MY

    35 Pages

  43. E3NC-L/-S

    16 Pages

  44. NE0A-SCPU01

    6 Pages

  45. LY

    14 Pages

  46. G2R-[]-S

    11 Pages

  47. G7T

    7 Pages

  48. G2A

    9 Pages

  49. G2A-434

    7 Pages

  50. G2AK

    7 Pages

  51. MK-S

    9 Pages

  52. MK-S(X)

    12 Pages

  53. MM

    17 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages