Overview
The K8AK-TS/-PT Thermistor Motor Protection Relay is designed to monitor temperature rise due to internal motor loss. It includes features for temperature, phase sequence, and phase loss monitoring, all within a compact 22.5-mm DIN size. The relay supports side-by-side mounting and has a test/reset button for confirming output operation. It also monitors thermistor disconnections and short circuits, with options for manual or automatic resetting.
Ordering Information
Available models include K8AK-PT1 for phase sequence, phase loss, and temperature monitoring, and K8AK-TS1 for temperature monitoring. Power supply options are 100 to 240 VAC or 24 VAC/DC.
Ratings and Specifications
The relay operates on 24 VAC/DC or 100 to 240 VAC, with power consumption of 1.8 VA/1.0 W max for 24 VAC/DC and 3.5 VA max for 100 to 240 VAC. It features manual or automatic reset methods, with indicators for power and alarm outputs. The output relay is rated for 5 A at 250 VAC or 30 VDC, with a mechanical life of 10 million operations.
Specifications
The relay functions within 85% to 110% of rated power supply voltage and 50/60 Hz frequency. It detects phase loss at 80%±10% of rated input and has a PTC thermistor operating value precision of 3,100 Ω ±5%. It complies with standards such as EN 60947-5-1 and UL 508.
Connections
The terminal diagram provides connection details, with precautions for hazardous voltage and recommended ferrules for wiring. The relay supports both automatic and manual output reset methods.
Operation Methods
The relay includes a TEST/RESET key for testing and resetting operations, with hysteresis between operating and reset values for PTC thermistor input.
Safety Precautions
Warnings highlight risks of electrical shock and fire, advising to confirm input voltage is off before wiring. The product should not be used in environments with water, oil, dust, corrosive gases, or rapid temperature changes.
Conclusion
The K8AK-TS/-PT relay is a robust solution for motor protection, offering comprehensive monitoring capabilities and compliance with international safety standards.
Installation and Wiring Instructions
  • Ensure correct terminal polarity and wiring connections; power supply terminals lack polarity.
  • Avoid incorrect wiring of input and output terminals.
  • Verify power supply voltage and loads are within product specifications.
  • Use specified size crimp terminals for wiring.
  • Do not connect unused terminals.
  • Use a power supply that reaches rated voltage within 1 second of being turned on.
  • Keep wiring separate from high voltage and high current lines.
  • Avoid installing near equipment generating high frequencies or surges.
  • Install an external switch or circuit breaker for quick power-off capability.
  • Ensure indicators function correctly; they may deteriorate in certain environments.
  • Do not use the product if dropped; internal components may be damaged.
  • Understand and follow catalog instructions.
  • Avoid installing the product in a way that places a load on it.
  • Dispose of the product as industrial waste when discarding.
  • Handle the product only by trained electricians.
  • Check wiring before supplying power.
  • Avoid installing near heat sources.
  • Perform periodic maintenance.
Operating Methods
  • Use suitable power supply voltage and converters with rated outputs.
  • Clean with commercial alcohol, not thinners or solvents.
  • Input waveform distortion must not exceed 30%.
  • Product is not suitable for thyristor control or secondary side of an inverter without a noise filter.
Mounting and Removal
  • Mount to DIN Track with tab at top and hooks at bottom; ensure hooks lock into place.
  • Remove by pulling down on bottom hook with a screwdriver and lifting the product.
Terms and Conditions
  • Omron provides a 12-month warranty against defects in materials and workmanship.
  • No warranty for non-infringement, merchantability, or fitness for a particular purpose.
  • Omron's liability is limited to product replacement, repair, or refund.
  • Omron is not liable for special, indirect, incidental, or consequential damages.
  • Buyer is responsible for determining product suitability for their application.
  • Omron is not responsible for user programming of programmable products.
  • Specifications may change without notice; consult Omron for confirmation.
See more

Catalog excerpts

K8AK-TS/PT-1

omRon Thermistor Motor Protection RelayK8AK-TS/-PT C€ Monitor Temperature Rise through Internal Motor Loss • Temperature, phase sequence, and phase loss monitoring with the Din 22.5-mm-sized K8AK-PT Relays. • Side-by-side mounting of K8AK-PT Relays. •Specially designed for internal motor monitoring; no setting required. •Test/Reset Button for confirmation of output operation. • Monitoring also performed for thermistor disconnections and short circuits. • Manual or automatic resetting with the same Relay. A Refer to Safety Precautions on page 8. Refer to page 7 for commonly asked questions. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information List of Models

 Open the catalog to page 1
K8AK-TS/PT-4

Connections Terminal Diagram K8AK-PT1 100-240VAC A Control Output Relay output 250 VAC, 5 A (resistive load) 30 VDC, 5 A (resistive load) Input Range Y1-T2 open Automatic output reset Output Method Y1-T2 closed Manual output reset Relay Output Common B Power Supply Voltage Note: 1. Terminal application depends on the model. 2. Do not connect anything to terminals that are shaded in gray. 3. The T1, T2, and Y1 terminals are not isolated from the three-phase voltage input (L1, L2, and L3), which carries a hazardous voltage (480 V max.). Use cables with reinforced insulation for wiring and connect...

 Open the catalog to page 4
K8AK-TS/PT-5

For ferrules with an insulation sleeve. 7 to 8 mm max. •Keys Item Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part inserted into the terminal must be 8 mm or less to maintain dielectric strength after connection. For 2.5 mm2 or smaller solid wires -1 7 to 8 mm max Recommended ferrules Phoenix Contact • Al 1,5-8BK (for AWG16) • Al 1-8RD (for AWG18) • Al 0,75-8GY (for AWG18) 2. Tightening torque: 0.49 to 0.59 N-m Setting the Output Reset Method Use the Y1 and T2 terminals to set the...

 Open the catalog to page 5
K8AK-TS/PT-6

K8AK-TS/-PT Timing Charts ●Automatic Output Reset (Y1-T2: Open) ●Manual Output Reset (Y1-T2: Closed) Power supply voltage Power supply voltage Three-phase Normal input error Three-phase Normal input error 3,100 Ω TS_ALM t1: Power ON lock (0.6 s) ●Test Mode ●Using Y1-T2 as Remote Reset Terminals Power supply voltage Power supply voltage Three-phase input error Three-phase Normal input error 3,100 Ω Open (Automatic output reset) Y1-T2 status* Open (Automatic output reset) Y1-T2 status.* Closed (Manual output reset) Closed (Manual output reset) Relay contacts (11-14) PH_ALM PH_ALM TS_ALM * When...

 Open the catalog to page 6
K8AK-TS/PT-7

K8AK-TS/-PT Questions and Answers Checking Operation PTC Thermistor Input Operation Operating Value The input resistance gradually increases from around 1 kΩ. The operating value is the input value for which the alarm indicator (TS_ALM) lights. The contact outputs switch simultaneously so that you can confirm operation. Note: Refer to the timing charts for the operating methods for reference. Can phase loss be detected on the load side? In principle, phase loss cannot be detected on the load side because the K8AK-PT1 measures three-phase voltage to determine phase loss. Is it possible to detect...

 Open the catalog to page 7
K8AK-TS/PT-8

Warning Indications K8AK-TS/-PT Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Electrical shock may occasionally cause serious injury. Confirm that the input voltage is OFF before starting any wiring work and wire all connections correctly. Electrical shock may cause minor injury. Do not touch terminals while electricity is being supplied. There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to...

 Open the catalog to page 8
K8AK-TS/PT-9

Precautions for Safe Use 1. Do not use or store the product in the following locations. • Locations subject to water or oil • Outdoor locations or under direct sunlight • Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) • Locations subject to rapid temperature changes • Locations prone to icing and dew condensation • Locations subject to excessive vibration or shock • Locations subject to wind and rain • Locations subject to static electricity and noise • Habitats of insects or small animals 2. Use and store the product in a location where the ambient...

 Open the catalog to page 9
K8AK-TS/PT-11

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR...

 Open the catalog to page 11
K8AK-TS/PT-12

Industrial Automation Company www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel:...

 Open the catalog to page 12

All OMRON catalogs and technical brochures

  1. NX1P

    41  Pages

  2. J7KCA

    18  Pages

  3. CX-Drive

    80  Pages

Archived catalogs

  1. D4F

    8  Pages

  2. D4GS-N

    11  Pages

  3. E4E2

    5  Pages

  4. G9SE Series

    20  Pages

  5. NT series

    18  Pages

  6. Code Reader/OCR

    24  Pages

  7. CompoNet

    28  Pages

  8. E9NC-T

    2  Pages

  9. ZW Series

    24  Pages

  10. ZS Series

    32  Pages

  11. ZG2

    16  Pages

  12. FZ4 Series

    42  Pages

  13. VC-DL100

    6  Pages

  14. MS4800

    40  Pages

  15. CP1E

    12  Pages

  16. CP1

    12  Pages

  17. E5AC-T

    8  Pages

  18. E2EF

    8  Pages

  19. VT-X700

    6  Pages

  20. Sysmac Catalog

    410  Pages

  21. G5 Series

    59  Pages

  22. E3T Series

    6  Pages

  23. E3T Data Sheet

    26  Pages

  24. E3ZM-C

    14  Pages

  25. E3S-CL

    9  Pages

  26. E3S-A

    21  Pages

  27. E3S-R

    11  Pages

  28. E3S-GS3E4

    3  Pages

  29. D5A

    8  Pages

  30. D5F

    5  Pages

  31. SC

    5  Pages

  32. VB

    5  Pages

  33. NL

    8  Pages

  34. E6A2-C

    5  Pages

  35. E6B2-C

    5  Pages

  36. E6D-C

    5  Pages

  37. E6F-C

    5  Pages

  38. E6H-C

    5  Pages

  39. E4C-UDA

    5  Pages

  40. E4A-3K

    9  Pages

  41. E4B

    12  Pages

  42. G7J

    10  Pages

  43. G7Z

    9  Pages

  44. G4Q

    6  Pages

  45. MMK

    14  Pages

  46. MM

    17  Pages

  47. MK-S(X)

    12  Pages

  48. MK-S

    9  Pages

  49. G2AK

    7  Pages

  50. G2A-434

    7  Pages

  51. G2A

    9  Pages

  52. G7T

    7  Pages

  53. G2R-[]-S

    11  Pages

  54. LY

    14  Pages

  55. NE0A-SCPU01

    6  Pages

  56. E3NC-L/-S

    16  Pages

  57. MY

    35  Pages

  58. V680S Series

    68  Pages

  59. V680 series

    68  Pages

  60. TL-L

    5  Pages

  61. GLS

    3  Pages

  62. F92A

    4  Pages

  63. XS2

    29  Pages

  64. XS5

    25  Pages

  65. APR-S

    6  Pages

  66. SAO

    13  Pages

  67. SE

    15  Pages

  68. K2CM

    16  Pages

  69. K8AK-TH

    12  Pages

  70. K8AK-LS

    12  Pages

  71. K8DS-PZ

    12  Pages

  72. K8DS-PU

    12  Pages

  73. K8AK-PW

    12  Pages

  74. K8DS-PA

    12  Pages

  75. K8AK-PA

    12  Pages

  76. K8DS-PM

    12  Pages

  77. K8AK-PM

    16  Pages

  78. K8DS-PH

    12  Pages

  79. K8AK-PH

    12  Pages

  80. K8AK-VW

    12  Pages

  81. K8AK-VS

    12  Pages

  82. K8AK-AW

    16  Pages

  83. K8AK-AS

    12  Pages

  84. G9SA-300-SC

    9  Pages

  85. WS02-CFSC1-E

    3  Pages

  86. DST1 Series

    5  Pages

  87. G9SA

    16  Pages

  88. G9SB

    10  Pages

  89. G9SX-LM

    28  Pages

  90. G9SX/G9SX-GS

    49  Pages

  91. G9SX-SM/LM

    9  Pages

  92. G9SX-SM

    24  Pages

  93. G9SP

    28  Pages

  94. NX-SL/SI/SO

    20  Pages

  95. Vision Systems

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.