K8AK-PW

K8AK-PW
1 / 12 PagesView full catalog

K8AK-PW

Product catalog summary
Overview: The K8AK-PW is a three-phase voltage relay designed for industrial power supply monitoring. It is resistant to inverter noise and can detect both overvoltages and undervoltages in three-phase 3-wire or 4-wire systems. The device is easily configurable via DIP switches and supports global power standards.
Key Features:
  • Equipped with two SPDT output relays, each with a capacity of 5 A at 250 VAC.
  • Includes LED indicators for relay status monitoring.
  • Features an automatic reset with a fixed reset value of 5% of the operating value.
  • Adjustable operating time from 0.1 to 30 seconds.
  • Power ON lock time adjustable via DIP switch.
Specifications:
  • Rated input voltage varies by model and configuration (3-wire or 4-wire).
  • Input frequency range is 50/60 Hz.
  • Complies with EN 60947-5-1 and UL 508 standards.
  • Operating temperature range is -20 to 60°C.
  • Dimensions are 22.5 × 90 × 100 mm.
Installation and Operation:
  • Designed for DIN Track mounting with specific terminal wiring methods.
  • Connections for 3-wire mode: L1, L2, L3; for 4-wire mode: L1, L2, L3, N.
  • Overvoltage and undervoltage settings adjustable from -30% to 25% of rated input using knobs.
Safety Precautions:
  • Ensure input voltage is off before wiring.
  • Avoid use in explosive environments.
  • Do not disassemble or modify the product.
  • Tighten terminal screws to specified torque to prevent fires.
Safety Warnings and Precautions:
  • Warning: Indicates potential for serious injury or death.
  • Caution: Indicates potential for minor injury or property damage.
  • Precautions for Safe Use: Guidelines for safe usage, including avoiding certain storage and operational conditions.
  • Precautions for Correct Use: Instructions to prevent malfunction, including correct wiring and installation.
Installation and Operation Guidelines:
  • Avoid locations with water, oil, dust, corrosive gases, or extreme temperatures.
  • Ensure correct mounting and wiring according to specifications.
  • Use appropriate power supplies and maintain separation from high voltage lines.
  • Perform regular maintenance as per catalog instructions.
Warranty and Liability:
  • Omron offers a 12-month warranty against defects.
  • Disclaims implied warranties of merchantability or fitness for a particular purpose.
  • Liability limited to the product's purchase price; not responsible for indirect damages.
  • Buyer responsible for determining product suitability.
Product Specifications and Changes:
  • Specifications may change without notice for improvement.
  • Users should confirm specifications with Omron representatives.
Contact Information: Omron Corporation and regional headquarters contact details are available for inquiries and support.
See more

Catalog excerpts

K8AK-PW-1

omRon Three-phase Voltage RelayK8AK-PW C€ cW.s @ ® Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. • Greater resistance to inverter noise. new • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply. •Two SPDT output relays, 5 A at 250 VAC (resistive load). Separate outputs possible for overvoltages and undervoltages. •World-wide power specifications supported by one Unit (switchable using DIP switch). • Relay status can be monitored using LED indicator. A Refer to Safety Precautions on page 9. Refer to 8 for commonly asked questions. Ordering InformationList of Models Rated input* Note: Three-phase, three-wire or four-wire and the input range are switched using a DIP switch. * The power supply voltage is the same as the rated input voltage. •Single K8AK Monitors 3-phase Power Supply with 3 or 4 Wires Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings. [Phase to phase voltage (3 wires)] | Phase to neutral voltage (4 wires)]

 Open the catalog to page 1
K8AK-PW-3

Specifications Input frequency range •Relationship of Mounting Distance between K8AK-PW Relays and Ambient Temperature (Reference Values) The following diagram shows the relationship between the mounting distances and the ambient temperature. If the relay is used with an ambient temperature that exceeds these values, the temperature of the K8AK may rise and shorten the life of the internal components. Test method Sample: K8AK-PW Mounting distances: 0, 5, and 10 mm min. DIN Track Distance between products: d

 Open the catalog to page 3
K8AK-PW-4

Connections Terminal Diagram Control Output 21 Relay output 250 VAC, 5 A (resistive load) 30 VDC, 5 A (resistive load) Input Voltages Relay Output Monitoring 3-phase, 3-wire Power Supply Note: 1. Do not connect anything to terminals that are shaded in gray. 2. Use the recommended ferrules if you use twisted wires. Power supply AC/DC Timing Charts ●Overvoltage and Undervoltage Operation Diagram Overvoltage set value Overvoltage alarm indicator Flashing Undervoltage alarm indicator Overvoltage relay 11-14 Undervoltage relay 21-24 Note: 1. K8AK-PW@ output relay is normally operative. 2. The power...

 Open the catalog to page 4
K8AK-PW-5

NomenclatureFront •Indicators Item * The input across L1 and L2 is used for the internal power supply. Therefore, the power indicator will not be lit if there is no input across L1 and L2. •Setting Knobs Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part inserted into the terminal must be 8 mm or less to maintain dielectric strength after connection. For 2.5 mm2 or For ferrules with smaller solid wires an insulation sleeve. Recommended ferrules Phoenix Contact • Al 1,5-8BK...

 Open the catalog to page 5
K8AK-PW-6

•Input Connect to L1, L2, and L3 (for three-phase three-wire mode) or L1, L2, L3, and N (for three-phase four-wire mode), depending on the mode selected using pin 2 on the DIP switch. The Unit will not operate correctly if the DIP switch setting and the wiring do not agree. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. •Outputs Terminals 11, 12, and 14 are the output terminals for overvoltage (SPDT). Terminals 21, 22, and 24 are the output terminals for undervoltage (SPDT). * Use the recommended ferrules if you use twisted...

 Open the catalog to page 6
K8AK-PW-7

K8AK-PW Setting Method ●Overvoltage The overvoltage knob (OVER) is used to set the overvoltage. The overvoltage can be set to between −30% and 25% of the rated input voltage. Turn the knob while there is an input to the input terminals until the alarm indicator flashes (when the set value and the input have reached the same level.) Use this as a guide to set the voltage. The rated input depends on the model and DIP switch setting. Example: K8AK-PW1 with Pin 2 Turned OFF (Three-phase, Three-wire Mode) and Pins 3 and 4 Turned OFF (Rated Voltage of 200 V) The rated input voltage is 200 VAC and the...

 Open the catalog to page 7
K8AK-PW-8

Checking Operation Overvoltage Gradually increase the input from 80% of the set value. The input value will equal the operating value when the input exceeds the set value and the alarm indicator starts flashing. Operation can be checked by the relay output that will start after the operating time has passed. Undervoltage Gradually decrease the input from 120% of the set value and check the operation using the same method as for overvoltage. Example: For monitoring mode set to three-phase three-wire monitoring, a rated voltage of 200 V, and an operating time of 5 s. Note: K8AK-PW@ output relays...

 Open the catalog to page 8
K8AK-PW-9

Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Warning Indications There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to enter the product. Explosions may cause minor injuries. Do not use the product in locations with inflammable or explosive gases. There is a risk of minor electrical shock, fire, or device failure. Do not disassemble, modify, repair, or touch the inside of the product. Loose...

 Open the catalog to page 9
K8AK-PW-10

Precautions for Safe Use 1. Do not use or store the product in the following locations. • Locations subject to water or oil • Outdoor locations or under direct sunlight • Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) • Locations subject to rapid temperature changes • Locations prone to icing and dew condensation • Locations subject to excessive vibration or shock • Locations subject to wind and rain • Locations subject to static electricity and noise • Habitats of insects or small animals 2. Use and store the product in a location where the ambient...

 Open the catalog to page 10

All OMRON catalogs and technical brochures

  1. NX1P

    41  Pages

  2. J7KCA

    18  Pages

  3. CX-Drive

    80  Pages

Archived catalogs

  1. D4F

    8  Pages

  2. D4GS-N

    11  Pages

  3. E4E2

    5  Pages

  4. G9SE Series

    20  Pages

  5. NT series

    18  Pages

  6. Code Reader/OCR

    24  Pages

  7. CompoNet

    28  Pages

  8. E9NC-T

    2  Pages

  9. ZW Series

    24  Pages

  10. ZS Series

    32  Pages

  11. ZG2

    16  Pages

  12. FZ4 Series

    42  Pages

  13. VC-DL100

    6  Pages

  14. MS4800

    40  Pages

  15. CP1E

    12  Pages

  16. CP1

    12  Pages

  17. E5AC-T

    8  Pages

  18. E2EF

    8  Pages

  19. VT-X700

    6  Pages

  20. Sysmac Catalog

    410  Pages

  21. G5 Series

    59  Pages

  22. E3T Series

    6  Pages

  23. E3T Data Sheet

    26  Pages

  24. E3ZM-C

    14  Pages

  25. E3S-CL

    9  Pages

  26. E3S-A

    21  Pages

  27. E3S-R

    11  Pages

  28. E3S-GS3E4

    3  Pages

  29. D5A

    8  Pages

  30. D5F

    5  Pages

  31. SC

    5  Pages

  32. VB

    5  Pages

  33. NL

    8  Pages

  34. E6A2-C

    5  Pages

  35. E6B2-C

    5  Pages

  36. E6D-C

    5  Pages

  37. E6F-C

    5  Pages

  38. E6H-C

    5  Pages

  39. E4C-UDA

    5  Pages

  40. E4A-3K

    9  Pages

  41. E4B

    12  Pages

  42. G7J

    10  Pages

  43. G7Z

    9  Pages

  44. G4Q

    6  Pages

  45. MMK

    14  Pages

  46. MM

    17  Pages

  47. MK-S(X)

    12  Pages

  48. MK-S

    9  Pages

  49. G2AK

    7  Pages

  50. G2A-434

    7  Pages

  51. G2A

    9  Pages

  52. G7T

    7  Pages

  53. G2R-[]-S

    11  Pages

  54. LY

    14  Pages

  55. NE0A-SCPU01

    6  Pages

  56. E3NC-L/-S

    16  Pages

  57. MY

    35  Pages

  58. V680S Series

    68  Pages

  59. V680 series

    68  Pages

  60. TL-L

    5  Pages

  61. GLS

    3  Pages

  62. F92A

    4  Pages

  63. XS2

    29  Pages

  64. XS5

    25  Pages

  65. APR-S

    6  Pages

  66. SAO

    13  Pages

  67. SE

    15  Pages

  68. K2CM

    16  Pages

  69. K8AK-TH

    12  Pages

  70. K8AK-LS

    12  Pages

  71. K8AK-TS/PT

    12  Pages

  72. K8DS-PZ

    12  Pages

  73. K8DS-PU

    12  Pages

  74. K8DS-PA

    12  Pages

  75. K8AK-PA

    12  Pages

  76. K8DS-PM

    12  Pages

  77. K8AK-PM

    16  Pages

  78. K8DS-PH

    12  Pages

  79. K8AK-PH

    12  Pages

  80. K8AK-VW

    12  Pages

  81. K8AK-VS

    12  Pages

  82. K8AK-AW

    16  Pages

  83. K8AK-AS

    12  Pages

  84. G9SA-300-SC

    9  Pages

  85. WS02-CFSC1-E

    3  Pages

  86. DST1 Series

    5  Pages

  87. G9SA

    16  Pages

  88. G9SB

    10  Pages

  89. G9SX-LM

    28  Pages

  90. G9SX/G9SX-GS

    49  Pages

  91. G9SX-SM/LM

    9  Pages

  92. G9SX-SM

    24  Pages

  93. G9SP

    28  Pages

  94. NX-SL/SI/SO

    20  Pages

  95. Vision Systems

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.