Catalog excerpts

Phase-sequence Phase-loss RelayK8AK-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method • Greater resistance to inverter noise. new • Distinguishes between correct phases, phase sequence, and phase loss when power is turned ON. • Supports phase loss detection when the motor is operating. •5 A (resistive load) at 250 VAC, DPDT x 1. • Output status can be monitored using LED indicator. • Ideal to prevent reverse operation of motors. A Refer to Safety Precautions on page 8. Refer to page 7 for commonly asked questions. Ordering Information List of Models * The power supply voltage is the same as the rated input voltage.
Open the catalog to page 1
Specifications Input voltage range •Relationship of Mounting Distance between K8AK-PH Relays and Ambient Temperature (Reference Values) The following diagram shows the relationship between the mounting distances and the ambient temperature. If the relay is used with an ambient temperature that exceeds these values, the temperature of the K8AK may rise and shorten the life of the internal components. Test method Sample: K8AK-PH Mounting distances: 0, 5, and 10 mm min. DIN Track Distance between products: d
Open the catalog to page 3
Connections Terminal Diagram Control Output Relay output 250 VAC, 5 A (resistive load) 30 VDC, 5 A (resistive load) Input voltage Note: 1. Use the recommended ferrules if you use twisted wires. Power supply AC/DC Alarm load 21 Timing Charts ●Phase Sequence and Phase Loss Operation Diagram Phase Loss Operation Phase Sequence Operation L2 Note: 1. The K8AK-PH1 output contacts are normally operative. 2. The Relay will not operate if the input voltage drops below 70% of the minimum input value because L1 and L2 are also used to provide power. 3. Phase loss cannot be detected on the load side...
Open the catalog to page 4
NomenclatureFront •Indicators Item * The input across L1 and L2 is used for the internal power supply. Therefore, the power indicator will not be lit if there is no input across L1 and L2. Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part inserted into the terminal must be 8 mm or less to maintain dielectric strength after connection. For 2.5 mm2 or For ferrules with smaller solid wires an insulation sleeve. Recommended ferrules Phoenix Contact • Al 1,5-8BK (for AWG16) •...
Open the catalog to page 5
Three-phase Phase-sequence Phase-loss Relay K8AK-PH1 Optional Parts for DIN Track Mounting ●DIN Tracks PFP-100N PFP-50N
Open the catalog to page 6
Checking Operation Phase Sequence Switch the wiring, as shown by the dotted lines in the connection diagram, to reverse the phase sequence and check that the K8AK operates. Phase Loss Create a phase loss for any input phase and check that the K8AK operates. Can phase loss be detected on the load side? In principle, phase loss cannot be detected on the load side because the K8AK-PH measures three-phase voltage to determine phase loss. Is it possible to detect phase losses for motor loads while the motor is operating? Phase loss can be detected while the motor is operating. However, the...
Open the catalog to page 7
Warning Indications K8AK-PH Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Electrical shock may occasionally cause serious injury. Confirm that the input voltage is OFF before starting any wiring work and wire all connections correctly. Electrical shock may cause minor injury. Do not touch terminals while electricity is being supplied. There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to...
Open the catalog to page 8
Precautions for Safe Use 1. Do not use or store the product in the following locations. • Locations subject to water or oil • Outdoor locations or under direct sunlight • Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) • Locations subject to rapid temperature changes • Locations prone to icing and dew condensation • Locations subject to excessive vibration or shock • Locations subject to wind and rain • Locations subject to static electricity and noise • Habitats of insects or small animals 2. Use and store the product in a location where the...
Open the catalog to page 9
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...
Open the catalog to page 11
Industrial Automation Company www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120,...
Open the catalog to page 12All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages