Auxiliary Relay (Contactor Relay) J7KCA Series Same shape as J7KC magnetic contactors Ideal for standardizing panel design • Push-In Plus wiring Technology saves Wiring and Maintenance time • World's smallest size (*1) • High Contact Reliability (Min. 5 VDC, 3 mA) by Bifurcated contacts • Combination with Auxiliary contact units to configure a wide variety of contact variations • Coil surge absorber unit installed as standard (*2) • Auxiliary Relay with mechanically linked contacts according to EN 60947-5-1 in safety applications, combined with AUX contact blocks, whose switching function is controlled by a safety-related system • Certified as compliant with the main safety standards For the most recent information on models that have been certified for safety standards, refer to your OMRON website. *1. According to OMRON investigation, as of August 2019. For push-in models. *2. DC operated Refer to Safety Precautions on page 10. Model Number Structure Model Number Legend Order according to the format described in Ordering Information. J7KCA- @@ @@@@@ (1) (1) Contact configuration Code Contact configuration (2) Coil voltage Operation Coil voltage Coil voltage
Open the catalog to page 1Contactor relay
Open the catalog to page 2Insulation stop
Open the catalog to page 3Note: 1. Coil ratings: Characteristics for 200 VAC, 50 Hz / 200-220 VAC, 60 Hz 2. Coil power consumption value is the same for a coil that is not rated 200 VAC. 3. Indicated operate/release times for 200 VAC, 50 Hz. 4. Closed and open voltages of 100 V coil (100 VAC, 50 Hz/100-110 VAC, 60 Hz) are approximately one half the values in the table above. 5. Values in the table above are examples for 20°C cold condition. DC operated Coil power consumption Note: 1. Coil ratings: Characteristics for 24 VDC 2. Coil power consumption value is the same for a coil that is not rated 24 VDC. 3. Values in the...
Open the catalog to page 4Characteristics Auxiliary Rated insulation voltage Rated impulse dielectric strength Rated frequency Contact material Linked contact Operating temperature Ambient storage temperature Relative humidity Safety standard 50 mO max. (1 mA at 6 VDC using the voltage drop method) Double-break Ag alloy Available * -10 to +55°C (however, daily average shall not exceed 35°C) -40 to +65°C (no condensation or icing) Vibration resistance Shock resistance Contact resistance (reference value) Contact structure * A linked contact is a mechanism found mainly in auxiliary relays. (Applicable models: J73KCA-31,...
Open the catalog to page 5Auxiliary terminals Coil terminals 62 (for 16 rail mounting height) 3 Auxiliary terminals Coil terminals *1. When auxiliary contact unit (J73KC) is mounted Auxiliary contact
Open the catalog to page 6Option (Order Separately) Auxiliary contact unit Note: Refer to page 16 for linked contact relationships when combined with auxiliary relays.
Open the catalog to page 7Ratings Model * The DC operate (J7KCA-D-DC) has a varistor built into the main unit. DimensionsJ76KC-RC Internal connection diagram Insulation stop Guide for insertion into terminal (insertion) holes to stabilize holding of 1mm2 or less stranded wire (direct insertion).
Open the catalog to page 8DIN Rails (Order Separately) (Unit: mm) End Plate PFP-M Model SpacerPFP-S Model Note: 1. Order the parts above in units of ten. The prices shown above are standard prices for one piece. 2. Rails conform to DIN standards.
Open the catalog to page 9Warning Indications Do not touch or approach the product while or immediately after power is supplied. Electric shock or burn injuries may occur. Never disassemble, modify, or repair the product or touch any of the internal parts. Minor electric shock, fire, or malfunction may occasionally occur. Do not use the product in an environment where flammable or explosive gas is present. Relay life expectancy varies considerably with output load and switching conditions. Always consider the application conditions and use within the rated load and electrical life expectancy. • Do not use the product...
Open the catalog to page 10How to mount on rail Follow the procedures below to mount the product on the rail or remove it from the rail. (1) Tilt the product about 10° with respect to the rail. Engage the hook at the power supply side and gently push the product down. (2) Press the product against the rail. (3) Lift the product up to engage the hook at the load side with the rail. (4) Gently jiggle the product to check that the load-side hook is engaged with the rail. Removing from rail (1) Hold the product at the top and bottom. Push it downward to release the lower hook. Mounting angle Installation interval Mount with...
Open the catalog to page 11Wiring Removing wireWire with ferrule Common for electric wires with ferrules and stranded (1) Insert straight in until the ferrule contacts the terminal block. (2) After inserting, pull the wire lightly and check the connection. wires (direct insertion) Stranded wire (direct insertion) (1) Before inserting, twist the core wire of the electric wire. (2) Insert the recommended tool straight at about 10angle in the direction of the arrow, into the terminal block until the end touches the release hole. (3) With the tool inserted in the release hole, insert straight in until the wire contacts the...
Open the catalog to page 12Recommended Ferrules and Crimp Tools Recommended ferrules * OMRON's exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4*2,5 (manufactured by Phoenix Contact). Recommended flat-bladed screwdriver (Recommended tool) Use a flat-blade screwdriver to connect and remove wires. Use the flat-blade screwdriver shown in the table below. The following table shows manufacturers and models as of 2018/Dec. Voltage fluctuation range and voltage drop in control circuit • AC-operated (J7KCA-D-ACD) Must operate voltage: 85% to 110% of rated voltage However, this is the rated voltage for making....
Open the catalog to page 13The control coil of AC-operated does not contain a built-in surge absorber. Use an optional coil surge absorption unit if required. The control coil of DC-operated contains a built-in surge absorber (varistor). Therefore, it is not necessary to connect an external surge absorption circuit in a normal sequence circuit. (See Table 1) Connect the control coil terminals and various DC output devices as shown in Table 2. Note that the control coil terminals have A1 (plus) and A2 (minus) polarities. Table 1. Coil voltages and varistor voltages of DC-operated When the surge voltage reaches or exceeds...
Open the catalog to page 148 Pages
11 Pages
5 Pages
104 Pages
4 Pages
20 Pages
28 Pages
4 Pages
7 Pages
16 Pages
30 Pages
57 Pages
12 Pages
22 Pages
24 Pages
28 Pages
31 Pages
18 Pages
2 Pages
12 Pages
100 Pages
24 Pages
108 Pages
28 Pages
54 Pages
2 Pages
24 Pages
32 Pages
16 Pages
42 Pages
6 Pages
40 Pages
12 Pages
12 Pages
8 Pages
32 Pages
24 Pages
17 Pages
16 Pages
24 Pages
36 Pages
8 Pages
24 Pages
6 Pages
410 Pages
59 Pages
6 Pages
26 Pages
14 Pages
9 Pages
21 Pages
11 Pages
3 Pages
8 Pages
5 Pages
5 Pages
5 Pages
8 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
9 Pages
12 Pages
10 Pages
9 Pages
6 Pages
14 Pages
17 Pages
12 Pages
9 Pages
7 Pages
7 Pages
9 Pages
7 Pages
11 Pages
14 Pages
6 Pages
8 Pages
8 Pages
5 Pages
16 Pages
35 Pages
68 Pages
68 Pages
5 Pages
3 Pages
4 Pages
29 Pages
25 Pages
6 Pages
13 Pages
15 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
9 Pages
3 Pages
5 Pages
16 Pages
10 Pages
28 Pages
49 Pages
9 Pages
24 Pages
28 Pages
20 Pages
24 Pages
38 Pages
12 Pages
55 Pages
20 Pages