Ultra Slim Safety Relay Unit • Models of width 17.5 mm available with 2 or 3 poles. Models of width 22.5 mm with 3 poles also available. • Conforms to EN standards. (TUV approval) • DIN track mounting possible. A Be sure to read the “Safety Precautions”on page 9. Model Number Legend Note: Please see “Ordering Information” below for the actual models that can be ordered. 5. Input Configuration None: 1-channel or 2-channel input possible 0: None (direct breaking) 6. Miscellaneous A: Auto-reset, inverse input B: Auto-reset, + common input C: Manual reset, inverse input D: Manual reset, + common input 1. Function None: Emergency stop 3. Contact Configuration (OFF-delay Output) 0: None4. Contact Configuration (Auxiliary Output) 0: None 1: SPST-NC Note: 1. Relays with inverse inputs are used mainly when inputting signals from two mechanical switches. 2. Relays with positive commons are used mainly when inputting signals from a safety sensor or from one mechanical switch. * The G9SB-3010 can be applied to Safety Category 3 of the EN954-1 if double breaking is used.
Open the catalog to page 1Specifications Ratings Power Input *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
Open the catalog to page 2Connections Internal Connections G9SB-2002-A/C (24 VAC/VDC) G9SB-3012-A/C (24 VAC/VDC) Note: 1. For 1-channel input with G9SB-@@@-B/D models, short terminals T12 and T22. It is not possible to wire G9SB-@@@2-A/C models for 1-channel input. 2. Always provide a protective ground externally, e.g., on the power supply. * Only G9SB-301 □-□ models have terminals 33-34 and 41-42. Note: Grounding Be sure to ground externally, such as at the power supply. (1) G9SB-3010 directly cuts off power, and has no Safety Input. (2) For 1-channel input with G9SB-@@@-B/D, short circuit T12-T22 and then input. (3)...
Open the catalog to page 3Terminal Arrangement
Open the catalog to page 4Application Examples G9SB-2002-A (24 VAC/VDC) or G9SB-3012-A (24 VAC/VDC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Stop category Safety Limit Switch D4B-N/D4N/D4F Safety Relay Unit G9SB-2002-A/3012-A (24VAC/VDC) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Timing...
Open the catalog to page 5G9SB G9SB-2002-C (24 VAC/VDC) or G9SB-3012-C (24 VAC/VDC) with 2-channel Emergency Stop Switch Input/Manual Reset Highest achievable PL/ safety category Stop category Emergency stop switch A165E/A22E Safety Relay Unit G9SB-2002-C/3012-C (24VAC/VC) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. • The power supply to the motor M is turned OFF when the emergency stop switch S1 is pressed. • The power supply to the motor M is kept OFF until the reset switch S2 is pressed while...
Open the catalog to page 6G9SB G9SB-200-D (24 VAC/VDC) or G9SB-301-D (24 VAC/VDC) with 2-channel Safety Sensor/Manual Reset (PNP models only) Highest achievable PL/ safety category Stop category Safety Light Curtain F3SJ-A/-B/-E Safety Relay Unit G9SB-2002-D/3012-D (24VAC/VDC) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. • The power supply to the motor M is turned OFF when the beam is blocked. • The power supply to the motor M is kept OFF until the beam is unblocked and the reset switch S1 is pressed....
Open the catalog to page 7G9SB G9SB-3010 (24 VDC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Stop category Safety Limit Switch D4B-N/D4N/D4F Safety Relay Unit G9SB-3010 (24VDC) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 23 S2 Control Circuit Safety...
Open the catalog to page 8Safety PrecautionsBe sure to read the Common Precautions for Safety Warning at the following URL: http://www.ia.omron.com/. ^CAUTION Turn OFF the G9SB before wiring the G9SB. Do not touch the terminals of the G9SB while the power is turned ON, because the terminals are charged and may cause an electric shock. Precautions for Correct Use Failure Detection for Slow-starting Power Supply When using a power supply with a long start-up time, if power is switched on while input has been closed the internal circuits will detect a power voltage error and the product will not operate. Apply the voltage...
Open the catalog to page 9Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR...
Open the catalog to page 108 Pages
11 Pages
5 Pages
104 Pages
4 Pages
20 Pages
20 Pages
28 Pages
24 Pages
9 Pages
49 Pages
28 Pages
16 Pages
5 Pages
3 Pages
9 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
15 Pages
13 Pages
6 Pages
25 Pages
29 Pages
4 Pages
3 Pages
5 Pages
68 Pages
68 Pages
35 Pages
16 Pages
5 Pages
8 Pages
8 Pages
6 Pages
14 Pages
11 Pages
7 Pages
9 Pages
7 Pages
7 Pages
9 Pages
12 Pages
17 Pages
14 Pages
6 Pages
9 Pages
10 Pages
12 Pages
9 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
8 Pages
5 Pages
5 Pages
5 Pages
8 Pages
3 Pages
11 Pages
21 Pages
9 Pages
14 Pages
26 Pages
6 Pages
59 Pages
410 Pages
6 Pages
8 Pages
12 Pages
12 Pages
40 Pages
6 Pages
42 Pages
16 Pages
32 Pages
24 Pages
2 Pages
54 Pages
28 Pages
108 Pages
24 Pages
100 Pages
12 Pages
2 Pages
18 Pages
31 Pages
28 Pages
24 Pages
22 Pages
12 Pages
57 Pages
30 Pages
16 Pages
7 Pages
4 Pages
28 Pages
32 Pages
24 Pages
17 Pages
16 Pages
24 Pages
36 Pages
8 Pages
24 Pages
24 Pages
38 Pages
12 Pages
55 Pages
20 Pages