For the most recent information on models that have been certified for safety standards, refer to your OMRON website. The G9SA Series Offers a Complete Line-up of Compact Units. • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller. Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles. • Simple expansion connection. • OFF-delay models have 15-step OFF-delay settings. • Conforms to EN ISO13849-1 (PLe/Safety Category 4) *. • Both DIN track mounting and screw mounting are possible. * Except for some models. Refer to "Applicable Performance Level (PL)" on page 13, or "Reliability data for safety of control components_SISTEMA library" on OMRON's website. A Be sure to read the “Safety Precautions”on page 15 Model Number Structure Model Number Legend Note: 1. Please see “Ordering Information” on page 2 for the actual models that can be ordered. 2. Specify the power supply voltage when ordering. 1. Function None: Emergency stop EX: Expansion Unit 5. Input Configuration None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting time) None: No OFF-delay T075: 7.5 seconds T1 5: 15 seconds
Open the catalog to page 1| Specify the power supply voltage when ordering. Emergency-stop Units Note: Set to maximum values in the factory.
Open the catalog to page 2Power Input Item Model * When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max. Inputs Item Model * When an Expansion Unit is connected, the input current is increased by 30 mA max. Contacts *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not Including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5. The...
Open the catalog to page 3Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Note: 1. With 100 to 240-VAC type, be sure to connect PE to a protective ground. With 24-VAC/VDC type, if the power supply is not connected to a protective ground, be sure to connect PE to a protective ground. 2. With 24-VAC/VDC type, the power supply terminals A1 and A2 have polarities. A2 is the negative pole. *1. Use terminals A and B to switch reset mode. A to B open: Manual reset A to B closed: Auto-reset *2. Terminal T23 is used for 2-channel input with a positive...
Open the catalog to page 4*1. Terminal T23 Terminal T23 is used for 2-channel input with a positive common (when connecting a safety sensor with a PNP output). When T23 is being used, please open T21 and T22. For 1-channel input, short circuit T12-T23 before use. *2. Output Contacts G9SA-301: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. G9SA-501: Safety Output Contacts 13-14, 23-24, 33-34, 43-44, 53-54. Auxiliary Contact 61-62. G9SA-321-TQ Safety Output Contacts 13-14, 23-24, 33-34. Safety OFF-delay Output Contact 43-44, 53-54. Auxiliary Contact 61-62. *3. Terminals A and B A-B Opening: Manual...
Open the catalog to page 5Dimensions and Terminal Arrangement Twenty, M3 Twenty-four, M3 Twenty-four, M3 Twenty-one, M3 Connector cover * Note 1: The OFF-delay time setting switch is found on the G9SA-321-T@ only. 2: The K1 to K4 indicators light when the NO contacts of internal relays K1 to K4 close. * Do not remove unless an Expansion Unit is being used. PWR (green) K1 (green) K2 (green) OFF-delay time setting switch (See note 1) Note 1: The OFF-delay time setting switch is found on the G9SA-EX031-T@ only. 2: The K1 and K2 indicators light when the NO contacts of internal relays K1 and K2 close. OFF-delay time setting...
Open the catalog to page 6Application ExamplesG9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 _ S1: Safety limit switch KM1 and KM2: Magnetic contactor M: Motor...
Open the catalog to page 7G9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed and the reset switch S3 is pressed. Safety limit switch Limit switch Reset switch Magnetic contactor Motor
Open the catalog to page 8G9SA-301 (100 to 240 VAC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Safety limit switch Limit switch Magnetic contactor Motor
Open the catalog to page 9G9SA-301 (24 VAC/VDC) with 2-channel Emergency Stop Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the emergency stop switch is pressed. • The power supply to the motor M is kept OFF until the reset switch S2 is pressed while the emergency stop switch is released. Timing Chart Emergency stop switch S1 Reset switch S2 KM1 and KM2 (NO)...
Open the catalog to page 108 Pages
11 Pages
5 Pages
104 Pages
4 Pages
20 Pages
20 Pages
28 Pages
24 Pages
9 Pages
49 Pages
28 Pages
10 Pages
5 Pages
3 Pages
9 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
15 Pages
13 Pages
6 Pages
25 Pages
29 Pages
4 Pages
3 Pages
5 Pages
68 Pages
68 Pages
35 Pages
16 Pages
5 Pages
8 Pages
8 Pages
6 Pages
14 Pages
11 Pages
7 Pages
9 Pages
7 Pages
7 Pages
9 Pages
12 Pages
17 Pages
14 Pages
6 Pages
9 Pages
10 Pages
12 Pages
9 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
8 Pages
5 Pages
5 Pages
5 Pages
8 Pages
3 Pages
11 Pages
21 Pages
9 Pages
14 Pages
26 Pages
6 Pages
59 Pages
410 Pages
6 Pages
8 Pages
12 Pages
12 Pages
40 Pages
6 Pages
42 Pages
16 Pages
32 Pages
24 Pages
2 Pages
54 Pages
28 Pages
108 Pages
24 Pages
100 Pages
12 Pages
2 Pages
18 Pages
31 Pages
28 Pages
24 Pages
22 Pages
12 Pages
57 Pages
30 Pages
16 Pages
7 Pages
4 Pages
28 Pages
32 Pages
24 Pages
17 Pages
16 Pages
24 Pages
36 Pages
8 Pages
24 Pages
24 Pages
38 Pages
12 Pages
55 Pages
20 Pages