Less Wiring Required with Safety Light Curtain • Sensor connector allows direct connection to OMRON F3SJ Safety Light Curtains with PNP outputs. • Reduces wiring and prevents incorrect connection. • Connection to emergency stop switch also supported. •Conforms to EN standards (TUV approval). • DIN track mounting possible. A Be sure to read the “Safety Precautions"on page 8. 1. Function None: Emergency stop 2. Contact Configuration (Safety Output) 3: 3 PST-NO 3. Contact Configuration (OFF-delay Output) 0: None 4. Contact Configuration (Auxiliary Output) 0: None 5. Input Configuration None: 1-channel or 2-channel input possible Ordering InformationSafety Relay UnitEmergency-stop Unit with Sensor Connector Main contact Note: 1. Connect to the sensor connector using a special OMRON F3SJ Safety Light Curtain Connecting Cable. For details, refer to the information on accessories below. 2. The Safety Light Curtain and Connecting Cable are sold separately. Connecting Cables (for F3SJ - G9SA-300-SC connection only) Appearance Note: 1. The model numbers given in the table are for sets of two Cables, one for the emitter and one for the receiver. 2. F3SP-JDDD (F3SJ - F3SP-B1P Connecting Cables) cannot be used.
Open the catalog to page 1Specifications Ratings Power Input Contacts *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to turn OFF after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.
Open the catalog to page 2Connections Internal Connections J1 External diagnosis Note: Do not connect anything to terminals C1, D1, D2, E1, and E2. 14 Terminal Arrangement The pin arrangement at the Sensor is shown below. Connector (Sensor End) Emitter Connector Receiver Connector F3SJ-@@@@@P@@-@@-L F3SJ-@@@@@P@@-@@-D Pin number PWR (orange) K1 (green) Signal name Receiver Interlock selection input (INTERLOCK) Auxiliary output (AUXILIARY) Reset input (RESET) Test input (TEST) External relay monitor input (EDM)
Open the catalog to page 3Application Examples Connection to Safety Light Curtain Only (Auto-reset) Receiver External diagnosis Emitter connector External test switch Magnetic Contactors 3-phase motor 24-VDC Power Supply (S82K) Timing Chart +24 V 0V Light incident Light interrupted E1 External test switch (S1) F3SJ/F3SN-A/-B/F3SH-A OSSD K3, NC contact Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2, E1, and E2. * The Unit performs normal operation when S1 is open and external diagnosis when it is closed. K3, NO contact K1 and K2, NC...
Open the catalog to page 4G9SA-300-SC Connection to Safety Light Curtain Only (Manual Reset) Receiver External diagnosis Emitter connector Reset switch (momentary action switch) External test switch Magnetic Contactors 3-phase motor 24-VDC Power Supply (S82K) Timing Chart +24 V 0V Light incident Light interrupted E1 Reset switch (S1) External test switch (S2) Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2, E1, and E2. * The Unit performs normal operation when S2 is open and external diagnosis when it is closed. F3SJ/F3SN-A/-B/F3SH-A...
Open the catalog to page 5G9SA-300-SC Connection to Safety Light Curtain and Two Channels of Limit Switch Input (Auto-reset) 23 External diagnosis Emitter connector Limit switch (NO) Safety Limit Switch with direct opening mechanism (NC) (D4B-N, D4N, D4F) S3: External test switch KM1 and KM2: Magnetic Contactors M: 3-phase motor E1: 24-VDC Power Supply (S82K) Light incident Light interrupted External test switch (S3) Limit switches (S1 and S2) F3SJ/F3SN-A/-B/F3SH-A OSSD K3, NC contact Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2,...
Open the catalog to page 6G9SA-300-SC Connection to Safety Light Curtain and Two Channels of Emergency Stop Switch Input (Manual Reset) Receiver Emergency stop switch S1 11 External diagnosis Emitter connector Timing Chart Emergency stop switch (A22E) +24 V E1 Reset switch (momentary action switch) 0V External test switch Light incident Magnetic Contactors Light interrupted 3-phase motor Reset switch (S2) 24-VDC Power Supply (S82K) External test switch (S3) Limit switches (S1 and S2) Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2,...
Open the catalog to page 7Safety Precautions Precautions for Safe Use Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”. Failure Detection for Slow-starting Power Supply • Turn OFF the G9SA-300-SC before wiring the G9SA-300-SC. Do not touch the terminals of the G9SA-300-SC while the power is turned ON, because the terminals are charged and may cause an electric shock. • To conform to IEC61496-1 and UL508 when using the F3SJ ensure that the DC power supply satisfies all the conditions below. • The voltage is within the rated power supply voltage range (24 VDC ±10%). •...
Open the catalog to page 8Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR...
Open the catalog to page 98 Pages
11 Pages
5 Pages
104 Pages
4 Pages
20 Pages
20 Pages
28 Pages
24 Pages
9 Pages
49 Pages
28 Pages
10 Pages
16 Pages
5 Pages
3 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
15 Pages
13 Pages
6 Pages
25 Pages
29 Pages
4 Pages
3 Pages
5 Pages
68 Pages
68 Pages
35 Pages
16 Pages
5 Pages
8 Pages
8 Pages
6 Pages
14 Pages
11 Pages
7 Pages
9 Pages
7 Pages
7 Pages
9 Pages
12 Pages
17 Pages
14 Pages
6 Pages
9 Pages
10 Pages
12 Pages
9 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
8 Pages
5 Pages
5 Pages
5 Pages
8 Pages
3 Pages
11 Pages
21 Pages
9 Pages
14 Pages
26 Pages
6 Pages
59 Pages
410 Pages
6 Pages
8 Pages
12 Pages
12 Pages
40 Pages
6 Pages
42 Pages
16 Pages
32 Pages
24 Pages
2 Pages
54 Pages
28 Pages
108 Pages
24 Pages
100 Pages
12 Pages
2 Pages
18 Pages
31 Pages
28 Pages
24 Pages
22 Pages
12 Pages
57 Pages
30 Pages
16 Pages
7 Pages
4 Pages
28 Pages
32 Pages
24 Pages
17 Pages
16 Pages
24 Pages
36 Pages
8 Pages
24 Pages
24 Pages
38 Pages
12 Pages
55 Pages
20 Pages