G9SA-300-SC
9Pages

{{requestButtons}}

Catalog excerpts

G9SA-300-SC - 1

Less Wiring Required with Safety Light Curtain • Sensor connector allows direct connection to OMRON F3SJ Safety Light Curtains with PNP outputs. • Reduces wiring and prevents incorrect connection. • Connection to emergency stop switch also supported. •Conforms to EN standards (TUV approval). • DIN track mounting possible. A Be sure to read the “Safety Precautions"on page 8. 1. Function None: Emergency stop 2. Contact Configuration (Safety Output) 3: 3 PST-NO 3. Contact Configuration (OFF-delay Output) 0: None 4. Contact Configuration (Auxiliary Output) 0: None 5. Input Configuration None: 1-channel or 2-channel input possible Ordering InformationSafety Relay UnitEmergency-stop Unit with Sensor Connector Main contact Note: 1. Connect to the sensor connector using a special OMRON F3SJ Safety Light Curtain Connecting Cable. For details, refer to the information on accessories below. 2. The Safety Light Curtain and Connecting Cable are sold separately. Connecting Cables (for F3SJ - G9SA-300-SC connection only) Appearance Note: 1. The model numbers given in the table are for sets of two Cables, one for the emitter and one for the receiver. 2. F3SP-JDDD (F3SJ - F3SP-B1P Connecting Cables) cannot be used.

Open the catalog to page 1
G9SA-300-SC - 2

Specifications Ratings Power Input Contacts *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to turn OFF after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.

Open the catalog to page 2
G9SA-300-SC - 3

Connections Internal Connections J1 External diagnosis Note: Do not connect anything to terminals C1, D1, D2, E1, and E2. 14 Terminal Arrangement The pin arrangement at the Sensor is shown below. Connector (Sensor End) Emitter Connector Receiver Connector F3SJ-@@@@@P@@-@@-L F3SJ-@@@@@P@@-@@-D Pin number PWR (orange) K1 (green) Signal name Receiver Interlock selection input (INTERLOCK) Auxiliary output (AUXILIARY) Reset input (RESET) Test input (TEST) External relay monitor input (EDM)

Open the catalog to page 3
G9SA-300-SC - 4

Application Examples Connection to Safety Light Curtain Only (Auto-reset) Receiver External diagnosis Emitter connector External test switch Magnetic Contactors 3-phase motor 24-VDC Power Supply (S82K) Timing Chart +24 V 0V Light incident Light interrupted E1 External test switch (S1) F3SJ/F3SN-A/-B/F3SH-A OSSD K3, NC contact Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2, E1, and E2. * The Unit performs normal operation when S1 is open and external diagnosis when it is closed. K3, NO contact K1 and K2,...

Open the catalog to page 4
G9SA-300-SC - 5

G9SA-300-SC Connection to Safety Light Curtain Only (Manual Reset) Receiver External diagnosis Emitter connector Reset switch (momentary action switch) External test switch Magnetic Contactors 3-phase motor 24-VDC Power Supply (S82K) Timing Chart +24 V 0V Light incident Light interrupted E1 Reset switch (S1) External test switch (S2) Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1, D2, E1, and E2. * The Unit performs normal operation when S2 is open and external diagnosis when it is closed....

Open the catalog to page 5
G9SA-300-SC - 6

G9SA-300-SC Connection to Safety Light Curtain and Two Channels of Limit Switch Input (Auto-reset) 23 External diagnosis Emitter connector Limit switch (NO) Safety Limit Switch with direct opening mechanism (NC) (D4B-N, D4N, D4F) S3: External test switch KM1 and KM2: Magnetic Contactors M: 3-phase motor E1: 24-VDC Power Supply (S82K) Light incident Light interrupted External test switch (S3) Limit switches (S1 and S2) F3SJ/F3SN-A/-B/F3SH-A OSSD K3, NC contact Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1,...

Open the catalog to page 6
G9SA-300-SC - 7

G9SA-300-SC Connection to Safety Light Curtain and Two Channels of Emergency Stop Switch Input (Manual Reset) Receiver Emergency stop switch S1 11 External diagnosis Emitter connector Timing Chart Emergency stop switch (A22E) +24 V E1 Reset switch (momentary action switch) 0V External test switch Light incident Magnetic Contactors Light interrupted 3-phase motor Reset switch (S2) 24-VDC Power Supply (S82K) External test switch (S3) Limit switches (S1 and S2) Note: 1. The Safety Light Curtain EDM function and auxiliary outputs cannot be used. 2. Do not connect anything to terminals C1, D1,...

Open the catalog to page 7
G9SA-300-SC - 8

Safety Precautions Precautions for Safe Use Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”. Failure Detection for Slow-starting Power Supply • Turn OFF the G9SA-300-SC before wiring the G9SA-300-SC. Do not touch the terminals of the G9SA-300-SC while the power is turned ON, because the terminals are charged and may cause an electric shock. • To conform to IEC61496-1 and UL508 when using the F3SJ ensure that the DC power supply satisfies all the conditions below. • The voltage is within the rated power supply voltage range (24 VDC...

Open the catalog to page 8
G9SA-300-SC - 9

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...

Open the catalog to page 9

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. K8AK-AS

    12 Pages

  16. K8AK-AW

    16 Pages

  17. K8AK-VS

    12 Pages

  18. K8AK-VW

    12 Pages

  19. K8AK-PH

    12 Pages

  20. K8DS-PH

    12 Pages

  21. K8AK-PM

    16 Pages

  22. K8DS-PM

    12 Pages

  23. K8AK-PA

    12 Pages

  24. K8DS-PA

    12 Pages

  25. K8AK-PW

    12 Pages

  26. K8DS-PU

    12 Pages

  27. K8DS-PZ

    12 Pages

  28. K8AK-TS/PT

    12 Pages

  29. K8AK-LS

    12 Pages

  30. K8AK-TH

    12 Pages

  31. K2CM

    16 Pages

  32. SE

    15 Pages

  33. SAO

    13 Pages

  34. APR-S

    6 Pages

  35. XS5

    25 Pages

  36. XS2

    29 Pages

  37. F92A

    4 Pages

  38. GLS

    3 Pages

  39. TL-L

    5 Pages

  40. V680 series

    68 Pages

  41. V680S Series

    68 Pages

  42. MY

    35 Pages

  43. E3NC-L/-S

    16 Pages

  44. NE0A-SCPU01

    6 Pages

  45. LY

    14 Pages

  46. G2R-[]-S

    11 Pages

  47. G7T

    7 Pages

  48. G2A

    9 Pages

  49. G2A-434

    7 Pages

  50. G2AK

    7 Pages

  51. MK-S

    9 Pages

  52. MK-S(X)

    12 Pages

  53. MM

    17 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages