Catalog excerpts

Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor • Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. • No contact chattering for momentary voltage drops up to 50% of rated voltage. • Withstanding more than 4 kV between contacts that are different in polarity and between the coil and contacts. • Flame-resistant materials (UL94V-0-qualifying) used for all insulation material. • Standard models approved by UL and CSA. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Relays. Model Number Structure ■ Model Number Legend G7J - 2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal) 3. Contact Structure Z: Bifurcated contact None: Single contact Note: For bifurcated contact type, output is 1NO (4PST-NO) or 1NC (3PST-NO/SPST-NC). Ordering Information ■ List of Models Mounting type Contact form Screw terminals Quick-connect terminals Note: These Relays need a W-bracket (sold separately) for mounting. When ordering specify the voltage. Example: G7J-4A-P 240 VAC Rated coil voltage
Open the catalog to page 1
G7J PCB Terminals Contact form 4PST-NO Screw Terminals (Bifurcated Contact) Contact form 3PST-NO/ SPST-NC W-bracket Tab Terminals Contact form DPST-NO/ DPST-NC PCB Terminals (Bifurcated Contact) Rated voltage Rated voltage W-bracket Screw Terminals W-bracket Tab Terminals (Bifurcated Contact) Contact form Consult your OMRON representative for details on models not mentioned in this document. DPST-NO/ DPST-NC ■ Accessories (Order Separately) Name W-bracket Application Examples • Compressors for air conditioners and heater switching controllers. • Switching controllers for power tools or...
Open the catalog to page 2
Specifications ■ Coil Ratings Rated voltage AC Rated current Coil resistance 75% max. of rated 15% min. of rated 110% of rated voltage voltage voltage Power consumption Must-release voltage Must-operate voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil resistance. (The values given for AC rated current apply at 50 Hz or 60 Hz.) 2. Performance characteristic data are measured at a coil temperature of 23°C. 3. The maximum voltage is one that is applicable to the Relay coil at...
Open the catalog to page 3
G7J Note: 1. The above values are all initial values. 2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method. 3. The operate and the release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C. 4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric strength. 5. The electrical endurance was measured at an ambient temperature of 23°C. 6. This value was measured at a switching frequency of 60 operations per minute. ■...
Open the catalog to page 4
G7J KEMA (File No. 2001291.02) Model Coil ratings Contact ratings NO contact Class AC1: 25 A at 220 VAC 11.5 A at 380 to 480 VAC Class AC3: 11.5 A at 220 VAC and 8.5 A at 380 to 480 VAC *Class AC1: 1 A at 220 VAC Note: Add the suffix “-KM” to the model number when ordering. *This rating is the bifurcated contact rating. Reference KEMA approval: EN60947-4-1 for contacts Engineering Data AC resistive load (cosφ = 1) AC inductive load (cosφ = 0.4) (NO contact) AC resistive load (cosφ = 1) AC inductive load (cosφ = 0.4) (NC contact) DC resistive load (NO contact) DC resistive load (NC contact)...
Open the catalog to page 5
G7J Ambient Temperature vs. Coil Temperature Rise Ambient Temperature vs. Must-operate and Must-release Voltage Number of Relays: 5 G7J-4A 100 to 120 VAC Must-operate voltage Must-release voltage Coil temperature rise (°C) Must-operate and reset voltage (%) Must-operate voltage Must-release voltage Coil temperature rise (°C) Must-operate and reset voltage (%) Motor Load Item 3φ, 220 VAC, 2.7 kW (with a inrush current of 78 A and a breaking current of 13 A)
Open the catalog to page 6
Note: All units are in millimeters unless otherwise indicated. Screw Terminals with W-bracket Quick-connect Terminals with W-bracket Note: W-bracket is sold Mounting Holes Mounting Holes PCB Terminals with PCB Mounting iplil ll-ilil-liFl Mounting Dimensions
Open the catalog to page 7
Note: Terminals 43 and 44 of the G7J-4A-P(T) and contacts 41 and 42 of the G7J-3A1B-P(B) are bifurcated contacts. Accessories (Order Separately) R99-04 W-bracket (for G5F) 35 Mounting Holes
Open the catalog to page 8
Safety Precautions Refer to Safety Precautions for All Relays. Faston Tabs PCB Terminal-equipped Relays weigh approximately 140 g. Be sure that the PCB is strong enough to support them. We recommend dual-side through-hole PCBs to reduce solder cracking from heat stress. Do not impose excessive external force on the G7J in the horizontal or vertical directions when inserting the G7J to the Faston receptacle or pulling the G7J out from the Faston receptacle. Do not attempt to insert or pull out more than one G7J Unit together. Mount the G7J with its test button facing downwards. The Relay may...
Open the catalog to page 9
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...
Open the catalog to page 10All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages