G2R-[]-S - 1

General-purpose Relay Slim and Space-saving Power Plug-in Relay ■ Lockable test button models now available. ■ Built-in mechanical operation indicator. ■ Provided with nameplate. ■ AC type is equipped with a coil-disconnection self-diagnostic function (LED type). ■ High switching power (1-pole: 10 A). ■ Environment-friendly (Cd, Pb free). ■ Wide range of Sockets also available. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G2R 2. Number of Poles 1: 1 pole 2: 2 poles 6. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 3. Contact Form Blank: SPDT 4. Contact Type Blank: Single 7. Rated Coil Voltage Ordering Information List of Models Classification Enclosure rating Coil ratings Plug-in terminal Diode LED indicator and diode LED indicator and diode with test button LED indicator LED indicator with test button Contact form SPDT Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-E and P2RF-S. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. 3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. New model Example: G2R-1-S 12 VDC (S) Rated coil voltage

Open the catalog to page 1
G2R-[]-S - 2

G2R-@-S Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Applicable Relay model Screwless clamp terminal Screw terminal Back-mounting Socket Solder terminals Solder terminals Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting. Accessories for Screwless Clamp Terminal Socket (Option) Name Clip & Release Lever Socket Bridge Mounting Tracks Applicable Socket Mounting track Track-connecting Socket Spacer Mounting plate Back-connecting Socket * Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. Specifications...

Open the catalog to page 2
G2R-[]-S - 3

G2R-@-S Contact Ratings Number of poles Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load (cosφ = 1) 2 poles Inductive load (cosφ = 0.4; L/R = 7 ms) Rated load Rated carry current Failure rate (reference value) Characteristics Item Contact resistance Release (reset) time Mechanical: Electrical: Insulation resistance Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; contacts*; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between...

Open the catalog to page 3
G2R-[]-S - 4

Engineering Data Maximum Switching Power Plug-in Relays G2R-2-S AC inductive load (cosφ = 0.4) 10 DC resistive load DC inductive load (L/R = 7 ms) AC inductive load (cosφ = 0.4) Endurance Plug-in Relays G2R-2-S 10,000 250-VAC inductive load (cosφ = 0.4) 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 250-VAC 50 inductive load (cosφ = 0.4) Maximum voltage (%) Ambient Temperature vs Maximum Coil Voltage Note: The maximum voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C)

Open the catalog to page 4
G2R-[]-S - 5

Dimensions Note: All units are in millimeters unless otherwise indicated. Relays with Plug-in Terminals SPDT Relays G2R-1-S, G2R-1-SN, G2R-1-SNI (S) G2R-1-SD, G2R-1-SND, G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-1-SD (DC) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S

Open the catalog to page 5
G2R-[]-S - 6

G2R-@-S Track/Surface Mounting Sockets 38.2 max. Terminal Arrangement (Top View) Option (with ejector and label attached) Standard model Terminal Arrangement (Top View) Standard model Option (with ejector and label attached) Accessories for P2RF-@-S Socket Bridge Clip and Release Lever Insulating coating

Open the catalog to page 6
G2R-[]-S - 7

Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 3.2-dia. hole Note: Pin numbers in parentheses apply to DIN standard. Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole

Open the catalog to page 7
G2R-[]-S - 8

G2R-@-S Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-@-E Terminal Arrangement (Bottom View) Mounting Holes Tolerance: ±0.1 4 Terminal Arrangement (Bottom View) 7.5 Terminal plate thickness: 0.3

Open the catalog to page 8
G2R-[]-S - 9

Terminal Arrangement (Bottom View) Panel Cutout Five, 3 x 1.8-dia. holes 13.6±0.1 6 Terminal plate thickness: 0.3 Recommended thickness of the panel is 1.6 to 2.0 mm 7.5 Terminal plate thickness: 0.3 Terminal Arrangement (Bottom View) Terminal Arrangement (Bottom View) Mounting Height of Relay with Back-connecting Sockets G2R-@P

Open the catalog to page 9
G2R-[]-S - 10

It is recommended to use a panel 1.6 to 2.0 mm thick. Precautions Cation • Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. • Check that the test button is released before turning ON relay circuits. • If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. • Use an insulated tool when you operate the...

Open the catalog to page 10
G2R-[]-S - 11

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...

Open the catalog to page 11

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. G9SA-300-SC

    9 Pages

  16. K8AK-AS

    12 Pages

  17. K8AK-AW

    16 Pages

  18. K8AK-VS

    12 Pages

  19. K8AK-VW

    12 Pages

  20. K8AK-PH

    12 Pages

  21. K8DS-PH

    12 Pages

  22. K8AK-PM

    16 Pages

  23. K8DS-PM

    12 Pages

  24. K8AK-PA

    12 Pages

  25. K8DS-PA

    12 Pages

  26. K8AK-PW

    12 Pages

  27. K8DS-PU

    12 Pages

  28. K8DS-PZ

    12 Pages

  29. K8AK-TS/PT

    12 Pages

  30. K8AK-LS

    12 Pages

  31. K8AK-TH

    12 Pages

  32. K2CM

    16 Pages

  33. SE

    15 Pages

  34. SAO

    13 Pages

  35. APR-S

    6 Pages

  36. XS5

    25 Pages

  37. XS2

    29 Pages

  38. F92A

    4 Pages

  39. GLS

    3 Pages

  40. TL-L

    5 Pages

  41. V680 series

    68 Pages

  42. V680S Series

    68 Pages

  43. MY

    35 Pages

  44. E3NC-L/-S

    16 Pages

  45. NE0A-SCPU01

    6 Pages

  46. LY

    14 Pages

  47. G7T

    7 Pages

  48. G2A

    9 Pages

  49. G2A-434

    7 Pages

  50. G2AK

    7 Pages

  51. MK-S

    9 Pages

  52. MK-S(X)

    12 Pages

  53. MM

    17 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages