
Catalog excerpts

Smart Fiber Amplifier Units Sensor Communications Units Saving Space Start with Smart! Easily select the most reliable Fiber Unit for your detection conditions. Beam Improvements Standard Installation Fiber Units Selection Guide Fiber Sensor Best Selection Catalog Transparent Objects Best Selection Environmental Immunity Fiber Sensor Features Fiber Amplifiers, Technical Model Index Guide and Communications Installation Information Precautions Unit, and Accessories
Open the catalog to page 1
Fiber Sensor Fiber Sensor Features Optimal Fiber Sensor for additional Fiber Units for various Installation Conditions, Easy “Mounts Anywhere” Wide Variety Suitable for Harsh Environments Variously-shaped, compact heads allow installation in any small space. Fiber Units are available for various installation conditions and can be installed as is, even in harsh environments. “Achieve Easy Detection in Many Applications” Smart Tuning Automatic Setting of Optimum Values once with a workpiece and once without a workpiece Just press the button to set the optimum incident level and threshold....
Open the catalog to page 2
All in One Desk-top Navigation Fiber Sensor Best Selection Fiber Sensor Fiber Units for various Installation Conditions, installation when starting production. Fiber Sensor Features Fiber Sensor Features Optimal Fiber Sensor for additional Fiber Amplifier Units with easy optimum setting Easy “Mounts Anywhere” Wide Variety Suitable for Harsh Environments Variously-shaped, compact heads allow installation in any small space. Fiber Units are available for various installation conditions and can be installed as is, even in harsh environments. Fiber Units “Achieve Easy Detection in Many...
Open the catalog to page 3
Selection Guide Saving Space Standard Installation Fiber Units Selection Guide Fiber Sensor Features Beam Improvements Select a category. Fiber Unit Index Select a model. Category Pages 06 to 61 Select Accessories of Fiber Amplifier Unit Before Selecting Fiber Units Flat Sleeved Small Spot The Fiber Units specifications give the sensing distance when the Fiber Unit and Fiber Amplifier Unit is combined. Check the Fiber Amplifier Unit series for easier selection. Fiber Amplifier Unit Series High Power Transparent Objects Environmental Immunity Chemicalresistant, Oil-resistant Area Detection 1...
Open the catalog to page 4
Fiber Unit Index Cylindrical Models Flat Models Sleeve Models (Close-range Detection) Ideal for installation in narrow spaces. The Fiber Unit is secured with a set screw. Mount directly in limited spaces without using special mounting brackets. Suitable for close-range detection. Ideal for detecting minute objects in areas with limited space. Beam Improvements Small-Spot, Reflective (Minute Object Detection) High-power Beam (Long-distance Installation, Dust-resistant) Narrow View Detection without Background Interference (Detection Across Clearance) Flat Sleeved Saving Space Standard...
Open the catalog to page 5
Standard Installation Threaded Models Through-beam → This Page Threaded Models Installation Information → 59 ,60 Page Through-beam Fiber Units (Set of 2) 07-A E32-T11N 2M (Free Cutting) 8.4 dia. Model display tube Selection Guide Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. 07 Fiber Sensor Features Standard Installation Fiber Sensor Features Bending radius of cable E3X-HD GIGA HS Other modes High Power...
Open the catalog to page 6
Standard Installation Threaded Models Through-beam → This Page Threaded Models Installation Information → 59 ,60 Page Through-beam Fiber Units (Set of 2) 07-A E32-T11N 2M (Free Cutting) 8.4 dia. Model display tube Selection Guide Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. 07 Fiber Sensor Features Standard Installation Fiber Sensor Features Bending radius of cable E3X-HD GIGA HS Other modes High Power...
Open the catalog to page 7
Standard Installation Threaded Models Fiber Sensor Features Saving Space Standard Installation Fiber Units Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. Beam Improvements Top-view Type Threaded Right-angle Type Flat Sleeved Small Spot High Power Reflective Fiber Units Sensing direction (Aperture angle) Sensing distance (mm) Size Bending radius of cable Chemicalresistant, Oil-resistant Area Detection...
Open the catalog to page 8
Standard Installation Threaded Models Reflective → This Page Installation Information → 58 ,59 Page Reflective Fiber Units 09-E E32-C31M 1M (Free Cutting) Opposite side 5.5, thickness 1.8 (Nickel-plated brass) Washer (Nickel-plated brass) 1 dia. emission fibers Note: There is a white line on the emitter fiber. M3 nuts (Nickel-plated brass) Washer (Nickel-plated brass) provided (2 of each) Model display tube Sixteen, 0.265 dia. receiver fibers Chemicalresistant, Oil-resistant Note: There is a white line on the emitter fiber. Note: There is a white line on the emitter fiber. E32-LD11 2M (Free...
Open the catalog to page 9
Standard Installation Cylindrical Models Fiber Sensor Features Through-beam → This Page • Inserted where space is limited. (Secured using a set screw.) • Ultramate space-saving by micro-fiber head. (1 dia. × 10 mm) Selection Guide secured with a set screw Saving Space Standard Installation Fiber Units Threaded Cylindrical Flat Sleeved Through-beam Fiber Units Beam Improvements High Power Narrow view Sensing distance (mm) Size Sensing direction Transparent Objects Bending Heatresistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Fiber Amplifiers, Technical Communications Model Index...
Open the catalog to page 10
Cylindrical Models Dimensions Installation Information → 60 Page Through-beam Fiber Units (Set of 2) 1 dia. (Stainless steel) Fiber Units 11-B E32-T22B 2M (Free Cutting) Sensing surface 0.5 dia. Cylindrical 11-C E32-T12R 2M (Free Cutting) Sensing surface 1 dia. Standard Installation Saving Space Selection Guide 11 Fiber Sensor Features Standard Installation High Power Heat-shrinkable tube Narrow view Retroreflective Limitedreflective Chemicalresistant, Oil-resistant Bending Heatresistant Transparent Objects Environmental Immunity Beam Improvements Small Spot Liquid-level Vacuum Area...
Open the catalog to page 11All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages