Digital Temperature Controller E5CC/E5EC The new standard in temperature control is higher in every respect E5CC (48 × 48 mm) / E5EC (48 × 96 mm) Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. 48 × 48 mm E5CC 48 × 96 mm E5EC 1
Open the catalog to page 1Digital Temperature Controller E5CC (48 × 48 mm) Large White PV Display That’s Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. • The white PV display with a height of 15.2 mm improves visibility. • Easy setup with the CX-Thermo (sold separately). 48 × 48 mm E5CC • Only 48 × 48 mm (C size) and provides five keys. As easy to operate as 48 × 96 mm (E size) models. Refer to Safety Precautions on page 32. • High-speed sampling at 50 ms. • Models with up to 3 auxiliary outputs, 4...
Open the catalog to page 2Model Number Legend and Standard Models Model Number Legend '1. Options with HB and HS alarms (001 and 003) cannot be selected if a current output is selected for the control output. '2. The control output cannot be used as a transfer output. '3. Option 004 can be selected only when "CX" is selected for the control outputs. Heating and Cooling Control • Using Heating and Cooling Control © Control Output Assignment If there is no control output 2, an auxiliary output is used as the cooling control output. If there is a control output 2, the two control outputs are used for heating and...
Open the catalog to page 3E5CC Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Front Covers Type Hard Front Cover Soft Front Cover Model Y92A-48H Y92A-48D Terminal Covers CX-Thermo Support Software Model E53-COV17 E53-COV23 Model EST2-2C-MV4 Note: The E53-COV10 cannot be used. Refer to page 11 for the mounted dimensions. Waterproof Packing Model Y92S-P8 Note: This Waterproof Packing is provided with the Digital Temperature Controller. Current Transformers (CTs) Hole diameter 5.8 mm 12.0 mm Model E54-CT1 E54-CT3 Adapter Model Y92F-45 Note: Use this Adapter when the panel has already...
Open the catalog to page 4E5CC Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Transfer output Number of outputs Output specifications Setting method Remote SP input Indication method Multi SP Other functions Ambient operating temperature Ambient operating humidity Storage temperature A in model number: 100 to 240 VAC, 50/60 Hz D in model...
Open the catalog to page 5Alarm Outputs Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit, (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1. Alarm type Alarm output operation When alarm value When alarm value Set the deviation in the set point by setting the alarm upper limit (H) and alarm lower...
Open the catalog to page 7E5CC Characteristics Indication accuracy (at the ambient temperature of 23°C) Transfer output accuracy Remote SP Input Type Influence of temperature *2 Influence of voltage *2 Input sampling period Hysteresis Proportional band (P) Integral time (I) Derivative time (D) Proportional band (P) for cooling Integral time (I) for cooling Derivative time (D) for cooling Control period Manual reset value Alarm setting range Affect of signal source resistance Insulation resistance Dielectric strength resistance Vibration Malfunction Shock resistance Destruction Malfunction Weight Degree of protection...
Open the catalog to page 8USB-Serial Conversion Cable * Use a high-power port for the USB port. Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Communications Specifications * The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications Setting Level. Current Transformer (Order Separately) Heater Burnout Alarms and SSR Failure *1 For heater burnout alarms, the heater current will be measured when the control output is ON, and the output will turn ON if the heater...
Open the catalog to page 9E5CC External Connections E5CC E5CC-@@ 3 @ 5 M - @ @ @ Control output 1 Relay output 250 VAC, 3A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max. (1) Relay outputs Models with 3 auxiliary outputs: 250 VAC, 2 A (resistive load) CX OUT1 + - Q 1 2 3 The E5CC is set for a K-type thermocouple (input type = 5) by default. An input error (s.err) will occur if the input type setting does not agree with the temperature sensor. Check the input type. (2) Auxiliary Outputs QQ Models with 1 Current Output Models with 1 Voltage...
Open the catalog to page 10E5CC Nomenclature E5CC Temperature unit Top View No.1 display Setup Tool port on top panel Operation indicators No. 2 display Level key Up key Mode key Shift (PF) key Down key Dimensions (Unit: mm) Controllers E5CC Panel Cutout Mounted Separately Group Mounted 73.1 4 (48 × number of units - 2.5)+1.0 0 60 1 48 × 48 45+0.6 0 44.8 × 44.8 48.8 58 Group mounting does not allow waterproofing. 60 min. 45+0.6 0 Waterproof Packing (Accessory) Mounting Adapter (Accessory) 45+0.6 0 Terminal Cover (E53-COV17) (Sold separately) The Setup Tool port is on the top of the Temperature Controller. It is used...
Open the catalog to page 11E5CC ● Waterproof Packing Y92S-P8 (for DIN 48 × 48) The Waterproof Packing is provided with the Temperature Controller. Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your...
Open the catalog to page 12All OMRON catalogs and technical brochures
-
D4F
8 Pages
-
D4GS-N
11 Pages
-
E4E2
5 Pages
-
Fiber SensorBest Selection Catalog
104 Pages
-
Fiber Unit E32-LT/LD
4 Pages
-
G9SE Series
20 Pages
-
NX-SL/SI/SO
20 Pages
-
G9SP
28 Pages
-
G9SX-SM
24 Pages
-
G9SX-SM/LM
9 Pages
-
G9SX/G9SX-GS
49 Pages
-
G9SX-LM
28 Pages
-
G9SB
10 Pages
-
G9SA
16 Pages
-
DST1 Series
5 Pages
-
WS02-CFSC1-E
3 Pages
-
G9SA-300-SC
9 Pages
-
K8AK-AS
12 Pages
-
K8AK-AW
16 Pages
-
K8AK-VS
12 Pages
-
K8AK-VW
12 Pages
-
K8AK-PH
12 Pages
-
K8DS-PH
12 Pages
-
K8AK-PM
16 Pages
-
K8DS-PM
12 Pages
-
K8AK-PA
12 Pages
-
K8DS-PA
12 Pages
-
K8AK-PW
12 Pages
-
K8DS-PU
12 Pages
-
K8DS-PZ
12 Pages
-
K8AK-TS/PT
12 Pages
-
K8AK-LS
12 Pages
-
K8AK-TH
12 Pages
-
K2CM
16 Pages
-
SE
15 Pages
-
SAO
13 Pages
-
APR-S
6 Pages
-
XS5
25 Pages
-
XS2
29 Pages
-
F92A
4 Pages
-
GLS
3 Pages
-
TL-L
5 Pages
-
V680 series
68 Pages
-
V680S Series
68 Pages
-
MY
35 Pages
-
E3NC-L/-S
16 Pages
-
61F-GPN-BT / -BC
5 Pages
-
NE1A-SCPU Series
8 Pages
-
NE1A-SCPU0[]-EIP
8 Pages
-
NE0A-SCPU01
6 Pages
-
LY
14 Pages
-
G2R-[]-S
11 Pages
-
G7T
7 Pages
-
G2A
9 Pages
-
G2A-434
7 Pages
-
G2AK
7 Pages
-
MK-S
9 Pages
-
MK-S(X)
12 Pages
-
MM
17 Pages
-
MMK
14 Pages
-
G4Q
6 Pages
-
G7Z
9 Pages
-
G7J
10 Pages
-
E4B
12 Pages
-
E4A-3K
9 Pages
-
E4C-UDA
5 Pages
-
E6H-C
5 Pages
-
E6F-C
5 Pages
-
E6D-C
5 Pages
-
E6B2-C
5 Pages
-
E6A2-C
5 Pages
-
NL
8 Pages
-
VB
5 Pages
-
SC
5 Pages
-
D5F
5 Pages
-
D5A
8 Pages
-
E3S-GS3E4
3 Pages
-
E3S-R
11 Pages
-
E3S-A
21 Pages
-
E3S-CL
9 Pages
-
E3ZM-C
14 Pages
-
E3T Data Sheet
26 Pages
-
E3T Series
6 Pages
-
G5 Series
59 Pages
-
Sysmac Catalog
410 Pages
-
VT-X700
6 Pages
-
E5AC-T
8 Pages
-
CP1
12 Pages
-
CP1E
12 Pages
-
MS4800
40 Pages
-
VC-DL100
6 Pages
-
FZ4 Series
42 Pages
-
ZG2
16 Pages
-
ZS Series
32 Pages
-
ZW Series
24 Pages
-
E9NC-T
2 Pages
-
Vision System FH series
54 Pages
-
CompoNet
28 Pages
-
F3SJ Series Safety Light Curtain
108 Pages
-
Code Reader/OCR
24 Pages
-
Fiber Sensor Best Selection Catalog
100 Pages
-
Portable Multi-logger ZR-RX70
12 Pages
-
Air Particle Sensor ZN-PD-S
2 Pages
-
NT series
18 Pages
-
Round Water-resistant Connectors
31 Pages
-
Safety Controller G9SP
28 Pages
-
E3FA PHOTOELECTRIC SENSORS
24 Pages
-
Switch Mode Power Supply S8VK-G
22 Pages
-
Data Logger ZR-RX Series
12 Pages
-
Programmable Terminals NS Series
57 Pages
-
DeviceNet Safety System
30 Pages
-
Switching Power Supplies
16 Pages
-
Photomicro Sensors
7 Pages
-
Displacement Sensors
4 Pages
-
R87F / R87T AC Axial Fans
28 Pages
-
H8PS Cam Positioner
32 Pages
-
OS32C Safety Laser Scanner
24 Pages
-
FQ Vision Sensor
17 Pages
-
ZN-PD Air Particle Sensor
16 Pages
-
S8EX Switch Mode Power Supply
24 Pages
-
CP1L CP series CP1L CPU Unit
36 Pages
-
E2EF
8 Pages
-
FQ2 Smart camera
24 Pages
Archived catalogs
-
SAFETY APPLICATION HANDBOOK
55 Pages
-
SMART REMOTE I/O
12 Pages
-
Sensor Accessories
38 Pages
-
REGULATION SOLUTIONS
24 Pages
-
Vision Systems
20 Pages