The document describes the Waste Converter® H, a system designed to treat waste directly on-site, transforming unsorted waste into a sterile, dry, stable, and homogeneous product. It is applicable in various settings such as labs, hospitals, clinics, and treatment centers.

Certifications
The system holds several certifications including ISO 9001, NATO AH649, RINA, M.O.G.C. 231, APHIS, and APHA.

Working Principles
The process involves seven steps completed in 30 minutes: waste loading, crushing, evaporation, superheating, sterilization, cooling down, and unloading. The system operates without pressure and is flame-free, ensuring safety.

Process Details
  • Waste Loading: Waste is manually loaded in plastic bags.
  • Crushing: The rotor grinds the material, raising the temperature to about 100°C.
  • Evaporation: Frictional heat evaporates moisture, maintaining a constant temperature of 100°C.
  • Superheating: Temperature increases to 151°C after moisture elimination.
  • Sterilization: Material is held at 151°C for 3 minutes under moist heat.
  • Cooling Down: Water and a vacuum pump reduce the temperature to 60°C.
  • Unloading: Treated material is discharged via a servo-operated valve.

Results
The process reduces waste volume by 80% and weight by 50%, producing an odorless, sterile, and unrecognizable product that can be stored without refrigeration.

Technical Specifications
The document provides detailed specifications for various models (H5000, H2000, H1000, H400, H200, H100) including treatment chamber volume, machine weight, footprint, power requirements, and waste processing capacity.

Environmental and Operational Benefits
  • No water consumption and pollutant emissions.
  • Easy to use with no special license required.
  • Safe storage with no dust, odor, or fermentation.
  • Low energy consumption and no need for waste segregation.

Global Presence
The system is used in 25 countries, with brokers and distributors worldwide, including major NATO navies and luxury yacht manufacturers.

Contact Information
OMPECO s.r.l., based in Torino, Italy, provides contact details for further inquiries.
See more

Catalog excerpts

MEDICALE-2

CONVERTER® H TREATING WASTE DIRECTLY ON SITE CERTIFICATIONS ISO 9001 NATO AH649 RINA M.O.G.C. 231 APHIS APHA

 Open the catalog to page 2
MEDICALE-4

APPLICATIONS _LABS _HOSPITALS _CLINICS _TREATMENT CENTERS _CLINICAL WASTE MANAGEMENT THE IDEA Transform unsorted waste in to a sterile dry, stable, homogeneous product.

 Open the catalog to page 4
MEDICALE-5

WASTE CHARACTERISTICS INFECTED WASTE humidity MUNICIPAL WASTE humidity ORGANIC WASTE humidity HUMIDITY 70%

 Open the catalog to page 5
MEDICALE-6

HOW IT WORKS WORKING PRINCIPLES SAFETY Flame free! SAFETY The system does not work under pressure! HIGH TEMPERATURE MOIST HEAT

 Open the catalog to page 6
MEDICALE-7

THE PROCESS SEVEN STEPS 30 MINUTES ONLY The heat generated by friction in the material causes the evaporation of the waste moisture and the temperature remains constant at around 100°C. Once all the moisture has been eliminated, the frictional heat causes the temperature of the material to increase to 151°C. Converter® equipment is authorized to treat waste through physical sterilization, modification, reduction of volume, dehydration and reduction of weight. WASTE LOADING COOLING DOWN The waste is loaded inside the chamber by hand in plastic bags and the lid is closed. The rotor starts and accelerates...

 Open the catalog to page 7
MEDICALE-8

WASTE MATERIAL includes several hazardous substances which can be eliminated only through thermal processes. *based on the moisture content WASTE BIN IS AN IDEAL BACTERIAL CULTURE Microorganism proliferation and spreading is the most common problem connected to the waste management because it directly affects the human health. 1 bacteria today At the end of the treatment with the Converter® H series the final product is a completely unrecognizable, odorless and sterile flock or “fluff”. The weight is reduced by 50%, and the volume by 80%. if vacuum packed the volume is reduced further and the...

 Open the catalog to page 8
MEDICALE-9

UNRECOGNIZABLE ODORLESS AND STERILIZED FLUFF RDF 3.5 ÷ 4.5 MWh/t* * nominal value AUTOMATIC VACUUM The waste can be kept without emitting odors for up to 90 days. NO ODORS NO WASTE STORAGE EASY STORAGE LESS SPACE REQUIRED

 Open the catalog to page 9
MEDICALE-11

TECHNICAL DETAILS 5000 liters waste hospital waste 500 to 600 kg/h Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm total installed power [kw] nominal motor power [kw] nominal current [a] peak current [a] electrical consumption [kw/kg]

 Open the catalog to page 11
MEDICALE-12

TECHNICAL DETAILS 2000 liters waste hospital waste Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm] total installed power [kw] nominal motor power [kw] nominal current [a] peak current [a] electrical consumption [kw/kg]

 Open the catalog to page 12
MEDICALE-13

TECHNICAL DETAILS 1000 liters waste hospital waste Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm] total installed power [kw] nominal motor power [kw] nominal current [a] peak current [a] electrical consumption [kw/kg]

 Open the catalog to page 13
MEDICALE-14

TECHNICAL DETAILS 400 liters waste hospital waste Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm] total installed power [kw] nominal motor power [kw] nominal current [a] peack current [a] electrical consumption [kw/kg]

 Open the catalog to page 14
MEDICALE-15

TECHNICAL DETAILS 200 liters waste hospital waste Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm] total installed power [kw] nominal motor power [kw] nominal current [a] peack current [a] electrical consumption [kw/kg]

 Open the catalog to page 15
MEDICALE-16

TECHNICAL DETAILS 100 liters waste hospital waste Specification treatment chamber volume [lt] machine dry weight [kg] machine footprint [mm - h] electric cabinet weight [kg] electric cabinet footprint [mm] total installed power [kw] nominal motor power [kw] nominal current [a] peack current [a] electrical consumption [kw/kg]

 Open the catalog to page 16
MEDICALE-17

NO POLLUTANT EMISSIONS Liquids present in the waste are separated and condensed NO WATER CONSUMPTION Can be reduced down to zero SAFE STOCK No dust No odor No fermentation EASY TO USE No special license is needed to operate NO WASTE SEGREGATION Time saving ECOFRIENDLY SUSTAINABLE ECONOMIC

 Open the catalog to page 17
MEDICALE-18

UNITED KINGDOM CZECH REPUBLIC PORTUGAL PHILIPPINES SINGAPORE PANAMA TUNISIA CROATIA MONTENEGRO PAKISTAN UNITED ARAB EMIRATES BOTSWANA 25 COUNTRIES • Our brokers are present worldwide; • Several local distributors operate exclusively in their territories; • Among our clients there are the 5 most important NATO Navies and manufactures of large luxury Yachts. SOUTH AFRICA

 Open the catalog to page 18
MEDICALE-19

OMPECO s.r.l. Via Cavalieri del Lavoro, 16 10024 Moncalieri Torino, Italy T. +39 011 02.40.108 www.ompeco.com [email protected] Legal headquarters and billing address: Corso Laghi 26 10051 Avigliana - Torino, Italy Reg. Imp. RI/PRA/2014/46068/800 R.E.A. di Torino 1188899 VAT n° IT11118350013 Information, photos and description contained in this publication are supplied for illustrative purposes and are not binding.

 Open the catalog to page 19

All OMPECO SRL catalogs and technical brochures

  1. AVIATION

    21  Pages

  2. Unite Mobile

    21  Pages

  3. URBANO

    19  Pages

  4. HORECA

    36  Pages

  5. NAVALE

    32  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.