Catalog excerpts
Maxiflex MP Meter Prover Module Model M1714B Meter Prover Module. DATASHEET FEATURES • Performs pulse interpolation for proving oil & gas flow meters in accordance with the Manual of Petroleum Measurement Standards Accepts up to four detector switch inputs from a meter prover. Receives pulses from a flow meter to be proved. Performs pulse interpolation calculations in real time. Compatible with the Maxiflex M1713A four channel pulse integrity module to support multiple flow meters on a single meter prover. Fits in any MAXIFLEX base I/O slot The Manual of Petroleum Measurement Standards Chapter 4 (Proving Systems) Section 6 (Pulse Interpolation) defines a method of “double-chronometry” or pulse interpolation for increasing the resolution of flow metering pulses when proving gas or oil meters used in custody transfer applications. General purpose electronic control equipment (such as PLC’s) are generally not able to meet the fast counting requirements needed to implement this method. This Maxiflex M1714B MP (Meter Prover) module is specifically designed to interface with compact meter provers, and provide the complete meter proving logic and pulse interpolation calculations in accordance with the standard. This module performs the following functions: • • Accepts up to four detector switch inputs from a meter prover. Any two can be enabled for a meter prover “run”. Accepts a pulse input from the flow meter to be “proved”. This input is designed to be compatible with the Maxiflex 4PI (four channel pulse integrity) module pulse output so that any of the flow meter pulse streams into any Maxiflex 4PI module in the system can be software selected for this function. Upon software command, performs the pulse interpolation function (as defined in the Manual of Petroleum Measurement Standards) and provides the result to the Maxiflex CPU Module. SPECIFICATIONS pulse interpolation using the “double chronometry” method in accordance with the Manual of Petroleum Measurement Standards Chapter 4 (Proving Systems) Section 6 Detector Switch Inputs Number 4 detector switch inputs Opto coupled input (externally powered) Electrical Specifications Input “ON” voltage Field Termination Screw clamp Plug-in Terminal Blocks Screw Terminal Wire Size Three LED indicators per switch input: Green indicates switch is “ON” Yellow indicates switch is active Red indicates switch has activated. For manageable wiring to the module, 0.5 mm2 is recommended with 2mm overall outside diameter Operating Temperature Flow Meter Pulse Input Storage Temperature 1 Flow meter pulse input Opto coupled input (externally powered) Electronics conformally coated Electrical Specifications Logic Power Consumption 1.2mA at 5Vdc nominal 2.4mA at 9Vdc nominal 7mA at 24Vdc nominal Green LED indicates when pulse input is “ON”. Pulse interpolation function Standards Compliance From Logic Power Supply Mass Excluding Packaging Including Packaging Ordering Information Description Order Code Performs all logic necessary to perform automated meter proving, and performs Copyright Omniflex ♦ Subject to change without notice
Open the catalog to page 1Maxiflex MP Meter Prover Module Model M1714B Meter Prover Module. ELECTRICAL CONNECTION DESCRIPTION Detector 1 Input positive Detector 1 Input negative Detector 2 Input positive Detector 2 Input negative Detector 3 Input positive Detector 3 Input negative Detector 4 Input positive Detector 4 Input negative No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection Meter Pulse Input positive Meter Pulse Input negative MECHANICAL CONFIGURATION Terminal Layout Wiring Access Note: Module shown with door open. Green Green Green Green Yellow...
Open the catalog to page 2All Omniflex catalogs and technical brochures
-
MAXIFLEX Bases
3 Pages
-
CONET Local Area Network
8 Pages
-
Model M1267B CPU P3e-R
8 Pages
-
Model M1265A CPU A3e
8 Pages
-
Model M1586A CONET PNIM
2 Pages
-
Model M1588D HARWELL NIM
2 Pages
-
Model M1711A HSC
2 Pages
-
Model M1322A 16DI-24
2 Pages
-
Model M1323A 16DI-48
2 Pages
-
Model M1326A 32DI-24
2 Pages
-
Model M1327A 64DI-24
2 Pages
-
Model M1341B 16DO
2 Pages
-
Model M1330A 8DI8RO
2 Pages
-
Model M1342A 32DO
2 Pages
-
Model M1372A 8RO
2 Pages
-
Maxilarm
15 Pages
-
Model C2321A Teleterm M2S
8 Pages
-
Model C2330B-11-0
6 Pages
-
Model C2330B-12-0
6 Pages
-
Model M1403A 16AI
2 Pages
-
Model M1412A 8AO
2 Pages
-
Model M1431B 8 VC ISO
2 Pages
-
Model M1432C 8 TC/mV ISO
3 Pages
-
Model M1433B 6 RTD ISO
2 Pages
-
Model C2360C-0-0 Teleterm M2
6 Pages
-
Model C2360B-0-0 Teleterm M2
8 Pages
-
C2404B
4 Pages
-
C118xB series
4 Pages
-
Model M1589D HART NIM
3 Pages
-
Model M1580A Dual Serial NIM
2 Pages
-
Model M1240B CPU T2
6 Pages
-
Model MT8150x OIT 15 Inch
2 Pages
-
Model MT8121x OIT 12.1 Inch
2 Pages
-
Model MT8070iH OIT 7 Inch
2 Pages
-
Model MT8100i OIT 10 Inch
2 Pages
-
Model M1022B BASE
3 Pages
-
Model C2475A OMNITERM LZD
6 Pages
-
Model C2474A OMNITERM LZI
6 Pages
-
Model C2166A PT-2000 24Vdc
3 Pages
-
Model MT8104xh OIT 10.4 Inch
2 Pages
-
Model M1102A PSU
2 Pages
-
Model MT6070ih OIT 7 Inch
2 Pages
-
Model MT6050i OIT 4.3 Inch
2 Pages
-
Model M1023B BASE
3 Pages
-
Model C2063B OMNITERM LPI
12 Pages
-
Model M1021B BASE
3 Pages
-
Model C2462A OT LPD
12 Pages
-
Next Generation Signal Conditioners
12 Pages
-
Industry Standard Alarm Annunciators
10 Pages