1. Catalogs
  2. Omniflex
  3. Model C2360B-0-0 Teleterm M2

Model C2360B-0-0 Teleterm M2

Model C2360B-0-0 Teleterm M2

Model C2360B-0-0 Teleterm M2

Product catalog summary
Overview: The TELETERM M2 Series is a range of programmable Remote Terminal Units (RTUs) designed for remote monitoring and control. These units are cost-effective and feature 12 configurable inputs/outputs, low power operation, and multiple communication options such as GSM, 3G UMTS, and CDMA. They are suitable for applications like energy management, environmental monitoring, and traffic management.
Features: The RTUs offer 12 inputs/outputs configurable as analog or digital, operate on 9-30V DC power, and include an SD card slot for data logging, an onboard temperature sensor, and a real-time clock with battery backup. The compact design allows for DIN rail mounting, and programming is done using the EziFORTH language.
Communication Options: The TELETERM M2 Series supports various communication ports, including RS232/RS485, GSM/EGSM/GPRS, 3G UMTS, and several radio frequency bands. Each model offers different communication capabilities tailored to specific regional requirements and applications.
Input/Output Configuration: The RTUs provide versatile I/O configurations, allowing each point to be set as a digital input, analog input, digital output, or analog output. Digital inputs can function as pulse or hours counters, while analog outputs support 4-20mA sourcing.
Specifications: The RTUs operate within a wide temperature range and comply with various safety and emission standards. They feature a 16-bit processor with a 40MHz clock speed, and the real-time clock offers a resolution of 10ms. The units are compatible with the Omniflex Data2Desktop service for secure data access via a web browser.
Applications: Typical applications include remote site monitoring, utilities monitoring, transport/cargo monitoring, and remote digital advertising sign management. The low power consumption makes them suitable for solar and battery-powered installations.
Specifications of Specific Modules:
  • Teleterm M2R-3 Module C236xB-33 (868MHz 315mW): Operating in the SRD g3 Band (869.525 MHz) with a transmit power of 315mW, receiver sensitivity of -112dBm, and FSK modulation. It offers an outdoor range of up to 20 km with a dipole antenna and up to 40 km with a hi-gain antenna. Approved for use in Europe and South Africa.
  • Teleterm M2R-4 Module C236xB-34 (920MHz 1W): Operating in the 915-928 MHz band with a settable transmit power from 1mW to 1W, receiver sensitivity of -110dBm, and FHSS FSK modulation. It offers an outdoor range of up to 10 km with a dipole antenna and up to 30 km with a hi-gain antenna. Approved for use in the USA and Australia.
Ordering Information: Various models are available, each with specific features such as integral modems, network ports, and additional serial ports. Examples include the Teleterm M2G1 with GSM/GPRS modem and the Teleterm M2R4 with a 900MHz 1W FHSS radio network port.
Accessories: Accessories include the Conet Terminator Board with surge suppression, MX Programming Cable, Conet Patch Cable, and MX RS232/485 Serial Patch Cable.
See more

Catalog excerpts

Model C2360B-0-0 Teleterm M2-1

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. DATASHEET • 12 Configurable Inputs and Outputs • Wide choice of communications options • EziForth Programmable • Internet Ready Comms options • SD Card Logging • Low power operation 12 Inputs and/or Outputs (Analog or Digital) Integral Real-Time Clock with Battery Backup Programmable for a wide range of applications. SD Memory Card Slot for off-line data logging. Wide operating temperature range On-board temperature sensor and voltage monitor Compact size for tight spaces Convenient DIN Rail mounting OVERVIEW The TELETERM M2 series is a state-of-the-art RTU range designed to expand the possibilities of remote monitoring and control by providing a cost effective platform with a wide range of features. Communications options include GSM, 3G UMTS (NextG Australia), CDMA, licence-free Radio in a number frequency bands, Conet Industrial LAN for use over existing plant cabling, and RS232 and RS485 serial. The TELETERM M2 comes with 12 universal I/O that can be configured for analogue or digital input or output according to your needs. The on board RS232/485 port can be used to acquire data from other third party devices using either the Modbus protocol, or by downloading a custom software protocol “plug-in”. This feature allows a wide variety of third party devices to be supported. The low power consumption of the the Teleterm M2 makes it suitable for use in solar powered and battery powered applications. The Teleterm M2 series can be programmed in the EziFORTH programming language, providing the ability to do local control, and custom logic. The Teleterm M2 also incorporates an SD memory card slot to support local data logging. Typical applications for the M2 include: • Energy Management and Remote Meter Reading. Environmental Monitoring Remote Site Monitoring Utilities monitoring Remote inventory monitoring Traffic Management Remote Digital Advertising Sign management Transport/Cargo Monitoring Vending machines Stay in touch – Take control with the Teleterm M2 Series from Omniflex. Copyright Omniflex ♦ Subject to change without notice

 Open the catalog to page 1
Model C2360B-0-0 Teleterm M2-2

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. General Layout Mechanical Dimensions 109,5 Height including serial cable Copyright Omniflex ♦ Subject to change without notice

 Open the catalog to page 2
Model C2360B-0-0 Teleterm M2-3

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. Communication Functions by Model Product Name Order Code 1x GSM/ 2.4GHz 920MHz 868MHz 920MHz RS232/ 3G RS232 EGSM/ Conet 63mW 100mW 315mW 1W Notes 12 I/O RS485 UMTS 1x GPRS Port Radio Radio Radio Radio Port Port RS232/ Port Port Port Port Port RS485 NOTES: 1. The EGSM/GPRS port is a quad band device operating on 900/1800/850/1900MHz. This is suitable for use on most countries’ GSM networks. Consult the factory for specific compatibility with your network. 2. The 3G UMTS port is a tri band device...

 Open the catalog to page 3
Model C2360B-0-0 Teleterm M2-4

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. Input/Output Configurable Options The M2G is equipped with 12 versatile input/output points (I/O points or IOP’s). Each I/O point can be individually configured from the options given in the following table: I/O Point Digital Input Analogue Input Digital Output Analogue Output Note 1: See the “Specifications” section of this document for detailed specifications of each I/O point option. Note 2: All 0-30V analogue inputs have increased resolution over the range 0-6V (equivalent to the 0-5V inputs)....

 Open the catalog to page 4
Model C2360B-0-0 Teleterm M2-5

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. SPECIFICATIONS COMMON TO ALL MODELS Input/Outputs All M2 RTU’s have 12 Input/Output Points (IOP configurable in software as analogue or digital, inputs or outputs. 0-30Vdc (software configurable to smaller ranges such as 1-5Volts) (See the table above for a matrix of available functions on each I/O Point.) < 0.15% of reading +6mV from 0 to 5.5V < 0.15% of reading +30mV from 5.5 to 30V 6mV from 0 to 5.5 Volts nominal (10 bits) 33mV from 5.5 to 30Volts nominal (10 bits) As a Digital Input (IO...

 Open the catalog to page 5
Model C2360B-0-0 Teleterm M2-6

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. standard: • Conet/s • Modbus ASCII (Master or Slave) • Modbus RTU (Master or Slave). • Other protocols written in the EventForth programming language may be downloaded. Baud Rate Maximum cable length Communication Standard Selected by the wiring to the DB9 connector Do not connect Rx Data (In) Tx Data (Out) Do not connect Ground Do not connect RTS (Out) CTS (In) Do not connect Rx Data + (In) Rx Data – (In) Do not connect Tx Data+ (Out) Ground Vcc Do not connect Do not connect Tx Data – (Out)...

 Open the catalog to page 6
Model C2360B-0-0 Teleterm M2-7

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. Data2Desktop Service Compatibility Secure Access to data from the M2G is made possible from a standard Web Browser using the Omniflex “Data2Desktop” Web Service. This service is available by monthly subscription. (D2D software pack required to be installed on M2U) Network Communications Specifications for the Teleterm M2S1 Network Ports Types Serial Protocols supported Supports Conet/s and Modbus ASCII and RTU – Master or Slave as standard, but other protocols may be downloaded. (Consult the...

 Open the catalog to page 7
Model C2360B-0-0 Teleterm M2-8

TELETERM M2 Series Programmable RTU’s Model C236xB Teleterm RTU’s with integrated communication ports. Operating Band Throughput Data Rate Special Radio Licence Requirements None. (operates in licence-free ISM band) 10 Frequency Hopping Sequences Transmit Power Outdoor Range (Line of Sight) Up to 10 km with dipole Up to 30 km with hi-gain antenna Receiver Sensitivity RPSMA Connector for external antenna Ordering Information ORDER CODE Teleterm M2G Programmable RTU with GSM/GPRS integral modem. Teleterm M2G Programmable RTU with 3G HSDPA/UMTS integral modem (Telstra NextG compatible) Teleterm...

 Open the catalog to page 8

All Omniflex catalogs and technical brochures

  1. Maxilarm

    15  Pages

  2. C2404B

    4  Pages

  3. C118xB series

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.