Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. Receive Text Message Alerts on your mobile Monitor Binary or Analogue Inputs Monitor any data over Modbus serial or Ethernet Acknowledge Alarms remotely or have them escalate to other mobiles Send up to 64 different messages. • Send to up to 10 Recipients • “On-Demand” messages allow remote monitoring and control. Integrated communications interface Send a daily status message 12 Direct Inputs (Analogue or Digital) Integral Real-Time Clock with Battery Backup Integrated Modbus Port (Master or Slave) Configurable for a wide range of applications. Wide operating temperature range Send up to 64 different messages Compact size for tight spaces Convenient DIN Rail mounting OVERVIEW The TELETERM ‘Silent Sentry’ is a state-of-the-art Remote SMS Alarm Monitor capable of monitoring a wide range of input types and sending SMS Alarm and status messages upon detection of an alarm condition. The Silent Sentry is equipped with 12 direct Binary or Analogue Inputs, plus a Modbus port allowing alarms from a variety of sources to be monitored. An optional Ethernet port allows connection to DCS, PLC or SCADA systems through Modbus/TCP. Up to 64 different SMS messages can be sent. The Silent Sentry can be configured for up to 10 SMS message recipients, each in one of three escalating priority groups. This allows messages to be sent to a selected group of recipients, and if not acknowledged within a set time, then sent to the second group of recipients, and if still not acknowledged, then sent to the third group of recipients. The addition of a regular update message capability ensures the ability of the Silent Sentry to react to alarms when they occur. The Silent Sentry is easily configurable by the user, using the free Omniset configuration software. Using Omniset PRO, the Silent Sentry can even be configured remotely over the GSM/CDMA network. The Silent Sentry can be connected to your existing alarm annunciator systems, and can even be used to remotely acknowledge alarms using your mobile phone. The Silent Sentry provides an easy solution to remotely monitoring your alarms. Send the Silent Sentry an SMS message to read a value or control an output. Typical Applications for the Silent Sentry include: • Remote Site Monitoring Computer Rooms Environmental and effluent Monitoring Small Sub-station monitoring Facilities Management Utilities Monitoring Bore-hole Monitoring. Intrusion Alarms Production Downtime Minimisation Inform the right person fastest with Teleterm Silent from Omniflex. Copyright Omniflex ♦ Subject to change without notice
Open the catalog to page 1Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. Input/Output Schedule The Silent Sentry is equipped with 12 versatile input/output points (IO points). Each IO point can be individually configured from the options given in the following table: I/O Point Digital Input Analogue Input Digital Output Analogue Output Serial Port Connections The selection of either RS232 or RS485 is accomplished by specific wiring of the serial port connector. No internal links or settings need be changed to select between RS232 and RS422/485. Pin Communication Standard Do not connect Rx Data...
Open the catalog to page 2Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. Electrical Connections 9-30Vdc Supply DIGITAL OUTPUTS DIGITAL INPUTS 9-30Vdc Supply ANALOGUE INPUTS ANALOGUE OUTPUTS Mechanical Dimensions 109,5 Height including serial cable Copyright Omniflex ♦ Subject to change without notice
Open the catalog to page 3Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. SPECIFICATIONS SMS MESSAGES all priority 3 recipients. SMS MESSAGES Number of messages Message Format 64 messages can be stored in the Silent Sentry. Each message can be triggered by a different event. Messages are formatted as follows: ID + Common Text (per Silent Sentry) (up to 40 characters) ID is a message ID number to uniquely identify each message sent. To ensure that an errant process alarm does not send SMS messages too often, it is possible to set a Hold Off time for all messages. Once a message has been sent to all...
Open the catalog to page 4Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. Input and Outputs The Silent Sentry has 12 Input/Output Points (IOP) that are configurable in software as analogue or digital, inputs or outputs. As an Analogue Input (I/O Points 1 – 6, 11, 12) Type Voltage Input referenced to 0V supply. 0-30Vdc (software configurable to smaller ranges such as 1-5Volts) IOP 1 to IOP 10 can be Digital Input, Digital Output, or Analogue Input < 0.15% of reading +6mV from 0 to 5.5V < 0.15% of reading +30mV from 5.5 to 30V IOP 11 and IOP 12 can be Digital input, Analogue Input or Analogue...
Open the catalog to page 5Teleterm Silent Sentry Models C2330B and C2331B SMS Alarm Monitor. Ethernet Port ( available on C2331B models only ) Protocols Modbus/TCP Class 0 Master or Slave Conet/e for remote programming and network routing. Network Port Fixed IP set during configuration. Modbus Protocols See Serial port for details Specifications Network Protocol Support Plug-in Memory Card Type Standard SD Memory Card (24mm x 32mm x 1.4mm) Storage Capacity SD Memory Card dependent: Up to 2Gb supported Card Format Data Format Data writable by program to suit application. Any text based file format may be written such...
Open the catalog to page 6All Omniflex catalogs and technical brochures
-
MAXIFLEX Bases
3 Pages
-
CONET Local Area Network
8 Pages
-
Model M1267B CPU P3e-R
8 Pages
-
Model M1265A CPU A3e
8 Pages
-
Model M1586A CONET PNIM
2 Pages
-
Model M1588D HARWELL NIM
2 Pages
-
Model M1711A HSC
2 Pages
-
Model M1322A 16DI-24
2 Pages
-
Model M1323A 16DI-48
2 Pages
-
Model M1326A 32DI-24
2 Pages
-
Model M1327A 64DI-24
2 Pages
-
Model M1341B 16DO
2 Pages
-
Model M1330A 8DI8RO
2 Pages
-
Model M1342A 32DO
2 Pages
-
Model M1372A 8RO
2 Pages
-
Maxilarm
15 Pages
-
Model C2321A Teleterm M2S
8 Pages
-
Model C2330B-11-0
6 Pages
-
Model M1403A 16AI
2 Pages
-
Model M1412A 8AO
2 Pages
-
Model M1431B 8 VC ISO
2 Pages
-
Model M1432C 8 TC/mV ISO
3 Pages
-
Model M1433B 6 RTD ISO
2 Pages
-
Model C2360C-0-0 Teleterm M2
6 Pages
-
Model C2360B-0-0 Teleterm M2
8 Pages
-
C2404B
4 Pages
-
C118xB series
4 Pages
-
Model M1589D HART NIM
3 Pages
-
Model M1580A Dual Serial NIM
2 Pages
-
Model M1240B CPU T2
6 Pages
-
Model MT8150x OIT 15 Inch
2 Pages
-
Model MT8121x OIT 12.1 Inch
2 Pages
-
Model MT8070iH OIT 7 Inch
2 Pages
-
Model MT8100i OIT 10 Inch
2 Pages
-
Model M1022B BASE
3 Pages
-
Model C2475A OMNITERM LZD
6 Pages
-
Model C2474A OMNITERM LZI
6 Pages
-
Model C2166A PT-2000 24Vdc
3 Pages
-
Model MT8104xh OIT 10.4 Inch
2 Pages
-
Model M1102A PSU
2 Pages
-
Model MT6070ih OIT 7 Inch
2 Pages
-
Model MT6050i OIT 4.3 Inch
2 Pages
-
Model M1023B BASE
3 Pages
-
Model C2063B OMNITERM LPI
12 Pages
-
Model M1021B BASE
3 Pages
-
Model C2462A OT LPD
12 Pages
-
Next Generation Signal Conditioners
12 Pages
-
Industry Standard Alarm Annunciators
10 Pages