PTC PSU/Charger Model C2194A 8W Power Supply/ Battery Charger • A Complete solution for small battery-backed dc instrument power systems. • Supply 12Vdc or 24Vdc systems with continuous power during ac line interruptions without the need for inverters or mains UPS’s • Ideal for Teleterm M2 RTU’s, data-loggers, remote field instrumentation, alarm systems, remote access systems etc. FEATURES • • • • Charging characterised for sealed lead-acid cells. 12Vdc or 24Vdc output selectable. Operates from 85-264Vac universal ac supply Under-voltage cut-out protects battery from deep discharge. Overview The PTC is a combined Power Supply and Battery Charger system with integrated standby battery management for small uninterruptible instrument supply applications. Just connect mains supply, standby battery and load for an industrial grade standby power supply system. This DIN rail mounted product is ideal for providing dc power to Teleterm M2-series RTU systems where battery backup is necessary to ensure continuous system operation during power failure. Applications include RTU’s, data-loggers, remote field instruments, alarm systems and access controllers. Managing battery-backed systems for optimum backup time and battery life can be tricky and expensive. This product incorporates many features that make installing such systems simple and foolproof: Under-voltage Cut-Out During prolonged power outages, the back-up battery will eventually discharge. If the load remains connected, the battery enters its “deep” discharge phase, which can Copyright Omniflex ♦ Subject to change without notice Over-current detection protects wiring against faults. AC detect output for mains monitoring. DIN Rail mounting Independent battery and load terminals for ease of installation. cause irreparable damage to the battery, and reduce its capacity and life. The PTC incorporates an under-voltage cut-out that disconnects the load when the battery voltage begins to fall, preserving the battery life. Fault Protection Batteries are capable of delivering enormous currents under system fault conditions that can damage wiring and equipment. The PTC incorporates an auto-resettable load cut-out, which disconnects the load under overcurrent fault condition. Charge Control The PTC controls the charging of the battery to ensure optimum life. Batteries can be kept on continuous charge as long without fear of damage through overcharging. System Monitoring The PTC provides an AC detect output. When AC is present and the supply is functioning correctly, this output is on. This output can be used to detect AC input or charger failures.

Open the catalog to page 1
Model C2194A PTC 24/12Vdc PSU/Battery Charger - 2

PTC PSU/Charger Model C2194A 8W Power Supply/ Battery Charger Typical System Connection Diagram N 10 E 11 Battery Charge Control Backup Battery Mechanical Details Copyright Omniflex ♦ Subject to change without notice

Open the catalog to page 2
Model C2194A PTC 24/12Vdc PSU/Battery Charger - 3

PTC PSU/Charger Model C2194A 8W Power Supply/ Battery Charger AC input voltage range Safety Conformance Input current at full load Switch-on inrush current Immunity – Fast Transients IEC 61000-4-4:1995 2 kV – DC power port 1 kV – input/output lines Supply Variations Design Life Surge withstand 2kV 1.2/50microsecond pulse (line to earth) Fast Transients Load Output Output Voltage Maximum rated load 13.0V – 14V on 12V switch position 26.0V-28.0V on 24V switch position 660mA continuous at 12V setting 330mA continuous at 24V setting Overload protection ORDER CODE AC line regulation over...

Open the catalog to page 3
Model C2194A PTC 24/12Vdc PSU/Battery Charger - 4

PTC PSU/Charger Model C2194A 8W Power Supply/ Battery Charger APPLICATION NOTES BATTERY SELECTION CHARGING TIME The PTC is designed to operate with sealed lead acid type batteries also known as Valve Regulated Lead Acid (VRLA) batteries. This type of battery is sealed except for a valve that opens when the internal gas pressure exceeds the design limits. (That is why it is important not to overcharge VRLA batteries). Generally, these batteries can be used in confined areas and can be mounted in any orientation. (see the specific manufacturer’s data for details.) The battery is charged in...