1. Catalogs
  2. Omniflex
  3. Model C2193A PTD PSU/BATT CHARGER

Model C2193A PTD PSU/BATT CHARGER

Model C2193A PTD PSU/BATT CHARGER

Model C2193A PTD PSU/BATT CHARGER

Product catalog summary
Overview
The PTD PSU/Charger Model C2193A is an 8W power supply and battery charger designed for small battery-backed DC instrument power systems. It operates from a 36-60V DC supply and provides continuous power to 12V or 24V systems during line interruptions. It is ideal for use with Teleterm M2 RTUs, data-loggers, remote field instrumentation, alarm systems, and remote access systems.

Features
  • Charging characterized for sealed lead-acid cells.
  • Selectable 12Vdc or 24Vdc output.
  • Under-voltage cut-out to protect battery from deep discharge.
  • Over-current detection to protect wiring against faults.
  • Supply interruption detect output.
  • DIN Rail mounting with independent battery and load terminals for easy installation.

Specifications
  • DC Input: 36-60Vdc, <0.25A at 36VDC, <0.17A at 60VDC, surge withstand 2kV.
  • Load Output: 13.0V – 14V on 12V setting, 26.0V-28.0V on 24V setting, maximum rated load 660mA at 12V, 330mA at 24V.
  • Battery Charger: Constant voltage charging, float voltage 13.5V – 13.8V on 12V setting, 27.0V-27.6V on 24V setting.
  • Environmental: Operating temperature -10°C to 50°C, storage temperature -10°C to 70°C.
  • Compliance: Conforms to IEC950; EN60950, emissions EN 55011:2008 Group I, Class A.

Application Notes
  • Battery Selection: Designed for sealed lead acid (VRLA) batteries, including AGM and Gel-Cell types. Steps for selecting battery capacity include calculating Ampere-hours, accounting for battery deterioration, temperature effects, and recharge time.
  • DC Detect Output: Monitors the presence/absence of DC supply and charger health. A green light indicates a healthy power supply.
  • Low Voltage Cutout: Disconnects the battery from the load to prevent deep discharge, reconnects when DC supply returns and battery is above restore voltage.
  • Charging Time: Utilizes constant current mode for rapid charging to 85-95% capacity, followed by float charge mode for full charge.
See more

Catalog excerpts

Model C2193A PTD PSU/BATT CHARGER-1

PTD PSU/Charger Model C2193A 8W Power Supply/ Battery Charger • Operates from 36-60Vdc Supply • A Complete solution for small battery-backed dc instrument power systems. • Supply 12Vdc or 24Vdc systems with continuous power during line interruptions • Ideal for Teleterm M2 RTU’s, data-loggers, remote field instrumentation, alarm systems, remote access systems etc. FEATURES • • • Charging characterised for sealed lead-acid cells. 12Vdc or 24Vdc output selectable. Under-voltage cut-out protects battery from deep discharge. Overview The PTD is a combined Power Supply and Battery Charger system with integrated standby battery management for small uninterruptible instrument supply applications. Just connect DC input supply, standby battery and load for an industrial grade standby power supply system. This DIN rail mounted product is ideal for providing dc power to Teleterm M2-series RTU systems where battery backup is necessary to ensure continuous system operation during power failure. Applications include RTU’s, data-loggers, remote field instruments, alarm systems and access controllers. Managing battery-backed systems for optimum backup time and battery life can be tricky and expensive. This product incorporates many features that make installing such systems simple and foolproof: Under-voltage Cut-Out During prolonged power outages, the back-up battery will eventually discharge. If the load remains connected, the battery enters its “deep” discharge phase, which can Copyright Omniflex ♦ Subject to change without notice Over-current detection protects wiring against faults. Supply interruption detect output. DIN Rail mounting Independent battery and load terminals for ease of installation. cause irreparable damage to the battery, and reduce its capacity and life. The PTD incorporates an under-voltage cut-out that disconnects the load when the battery voltage begins to fall, preserving the battery life. Fault Protection Batteries are capable of delivering enormous currents under system fault conditions that can damage wiring and equipment. The PTD incorporates an auto-resettable load cut-out, which disconnects the load under overcurrent fault condition. Charge Control The PTD controls the charging of the battery to ensure optimum life. Batteries can be kept on continuous charge as long without fear of damage through overcharging. System Monitoring The PTD provides an DC detect output. When input DC is present and the supply is functioning correctly, this output is on. This output can be used to detect input or charger failures.

 Open the catalog to page 1
Model C2193A PTD PSU/BATT CHARGER-2

PTD PSU/Charger Model C2193A 8W Power Supply/ Battery Charger Typical System Connection Diagram Battery Charge Control Backup Battery Mechanical Details Copyright Omniflex ♦ Subject to change without notice

 Open the catalog to page 2
Model C2193A PTD PSU/BATT CHARGER-3

PTD PSU/Charger Model C2193A 8W Power Supply/ Battery Charger DC input voltage range Input current at full load Surge withstand 2kV 1.2/50microsecond pulse (line to earth) Fast Transients Load Output Output Voltage Maximum rated load 13.0V – 14V on 12V switch position 26.0V-28.0V on 24V switch position 660mA continuous at 12V setting 330mA continuous at 24V setting 100Mohm at 500Vac – input to outputs to ground. Insulation Breakdown (100% tested for > 1second) Mechanical Width Weight Unpacked 12% (follows battery state of charge) Temperature Regulation Battery Charger Compliance to Standards...

 Open the catalog to page 3
Model C2193A PTD PSU/BATT CHARGER-4

PTD PSU/Charger Model C2193A 8W Power Supply/ Battery Charger APPLICATION NOTES BATTERY SELECTION CHARGING TIME The PTD is designed to operate with sealed lead acid type batteries also known as Valve Regulated Lead Acid (VRLA) batteries. This type of battery is sealed except for a valve that opens when the internal gas pressure exceeds the design limits. (That is why it is important not to overcharge VRLA batteries). Generally, these batteries can be used in confined areas and can be mounted in any orientation. (see the specific manufacturer’s data for details.) The battery is charged in two...

 Open the catalog to page 4

All Omniflex catalogs and technical brochures

  1. Maxilarm

    15  Pages

  2. C2404B

    4  Pages

  3. C118xB series

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.