Product catalog summary
Overview: The TESTRANO 600 is a portable, three-phase test system for power and distribution transformers, offering comprehensive testing capabilities with advantages such as reduced wiring, faster testing, and increased safety.
Key Features:
  • Three-phase power transformer test set with 3 x 33 A DC or 400 V AC.
  • Automatic tap changer control without additional accessories.
  • Fast transformer core demagnetization.
  • Operable via integrated display or software on a laptop.
Testing Capabilities:
  • Demagnetization to reduce inrush currents.
  • Transformer Turns Ratio (TTR) for detecting shorted or open-circuited conditions.
  • Dynamic Resistance for OLTC maintenance issues.
  • DC Winding Resistance for contact problems.
  • Short-Circuit Impedance for winding deformation.
  • Power/Dissipation Factor for insulation investigation.
  • Exciting Current for insulation and magnetic circuit assessment.
  • Vector Group Check for transformer vector group determination.
  • Frequency Response of Stray Losses for identifying short-circuits.
  • Quick Test for customizable procedures.
  • Cooldown Test for winding temperature determination.
Advantages of Three-Phase Testing:
  • Reduced rewiring effort.
  • Faster testing by energizing all phases simultaneously.
  • Automated tap changer control.
  • Phase shift verification in any winding configuration.
Technical Specifications:
  • Outputs: HV & LV outputs, frequency range DC to 599 Hz, power up to 4000 W.
  • Inputs: High accuracy across voltage and current ranges.
  • DC Resistance Measurement: High accuracy.
  • Ratio Measurement: Accurate across wide ratios.
Software and Control Options:
  • TESTRANO TouchControl for easy test preparation.
  • Primary Test ManagerTM for guided testing and data management.
  • PTMate App for on-site support.
Safety and Design:
  • Safety features include emergency stop button and safety lights.
  • Rugged, compact design suitable for on-site testing.
Technical Specifications:
- On-load tap changer voltage: 300 VRMS, accuracy 0.07% for AC/DC.
- Current clamp input: 3 VRMS. Tap switch current: 300 mA continuous, 9 A for 0.7 seconds.
- System requirements: Windows OS, multicore CPU, 4 GB RAM, 5 GB disk space.
- Dimensions: 580 × 386 × 229 mm, weight 20.6 kg.
- Environmental: Operates -10 °C to +55 °C, storage -30 °C to +70 °C.
- Power: 100 V to 240 V AC, 50/60 Hz.
- High-voltage output: 0 to 12 kV AC, max current 300 mA.
Performance and Accuracy:
- Capacitance range: 1 pF to 3 μF.
- Power factor and dissipation factor ranges with specified accuracy.
Ordering Information:
- Packages and accessories available, including cable extensions and software upgrades.
- Advanced control options and software licenses for enhanced capabilities.
Compliance and Standards:
- Complies with ISO 9001, ISO 4001, OHSAS 18001.
- Designed for routine testing and safety compliance.
Support and Services:
- OMICRON offers technical support, loaner devices, and training.
- Consulting, testing, diagnostics, and training services available worldwide.
See more

Catalog excerpts

TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-1

TESTRANO 600 Three-phase test system for comprehensive power and distribution transformer testing

 Open the catalog to page 1
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-2

One system for multiple tests on power transformers: TESTRANO 600 Touch-and-Test with TESTRANO 600 TESTRANO 600 is the world’s first portable, three-phase test system which supports all common electrical tests on single- and three-phase power and distribution transformers. Compared to conventional single-phase test sets the three-phase capabilities of TESTRANO 600 offer several advantages: > One setup can be used to perform various tests > The rewiring effort is significantly reduced > Testing time can be cut down to a third of the time > Increased safety as less trips up and down are needed...

 Open the catalog to page 2
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-3

TRANSFORMER TURNS RATIO Transformer turns ratio (TTR) measurements verify the operating principle of a power transformer to detect shorted turns and open-circuited conditions. In order to perform this test with up to 12 kV, the CP TD12 and MCA1 are required. EXCITING CURRENT Exciting current measurements are performed to assess the turn-to-turn insulation of the windings, the magnetic circuit of a transformer as well as the tap changer. In order to perform this test with 10 kV, the CP TD12 is required. SHORT-CIRCUIT IMPEDANCE / LEAKAGE REACTANCE Leakage reactance / short-circuit impedance measurements...

 Open the catalog to page 3
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-4

Three-phase solution to speed up and simplify power transformer Your advantages of true three-phase testing: >> Rewiring effort is significantly reduced >> Speeds up testing because all three phases are energized at once >> Fully automated control of tap changer during the test >> Verify the phase shift of any winding configuration Three wires are all you need TESTRANO 600 is connected to the high-voltage and lowvoltage side of the transformer by using specially designed multi-purpose cables. The cables, which support a 4-wire (Kelvin) connection, only have to be connected once at the transformer’s...

 Open the catalog to page 4
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-5

testing Three powerful sources Active discharge and fast demagnetization The compact and powerful design with three integrated sources enables you to perform high accuracy measurements in a fraction of the time required by other solutions: The active discharge function (patent pending) of TESTRANO 600 automatically discharges the winding within a matter of seconds, e.g. after resistance measurements have been performed. This speeds up testing time and increases the safety for the tester > 3-phase transformer turns ratio with 400 V L-L > 3-phase winding resistance with 33 A With TESTRANO 600,...

 Open the catalog to page 5
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-6

TESTRANO TouchControl – Easy test preparation and fast test execution TESTRANO 600 can be operated in multiple ways: >> Primary Test ManagerTM Standard is the default software and offers basic functionality on your laptop. >> Primary Test ManagerTM Advanced offers a guided test workflow, easy data management and automatic result assessment on your laptop. >> TESTRANO TouchControl, using the integrated touch display for fast and easy test workflow on the device. All three options support all diagnostic tests on power and distribution transformers. TESTRANO TouchControl TESTRANO TouchControl is...

 Open the catalog to page 6
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-7

Easy handling during test preparation During operation with TESTRANO TouchControl, you can choose between creating a new, manual test or loading an already prepared test. In order to identify your asset and keep your testing results organized, you can enter basic transformer nameplate information before starting your test. Best possible support during test preparation and execution Each test follows an intuitive two-step workflow. You can set the measurement parameters on the “Settings” screen and press “Start”. You can then review the results on the “Measurement” screen. Pre-configured wiring...

 Open the catalog to page 7
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-8

Primary Test Manager TM – Guided testing with easy data management The Primary Test ManagerTM (PTM) is the ideal software tool for the diagnostic testing and condition assessment of your power transformers, providing different PTM licenses depending on your needs: >> Primary Test ManagerTM Standard is the default software and offers basic functionality on your laptop. >> Primary Test ManagerTM Advanced offers a guided test workflow, easy data management and automatic result assessment on your laptop. Management of location, asset and test data PTM provides a well-structured database for managing...

 Open the catalog to page 8
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-9

and automatic result assessment Execution of diagnostic tests Result analysis and reporting PTM enables you to control and operate the connected test set directly from a computer. In order to assist you during testing, PTM helps you in defining your transformer with type-specific nameplate views. Results are automatically stored and organized in the database on your PC and are available for analysis and reporting. Each test can be automatically assessed according to international standards and guidelines or based on your individual limit values. Customized test plans Comparison tools for detailed...

 Open the catalog to page 9
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-10

Technical data and possible accessories TESTRANO 600 Outputs 0.01 % rd + 0.003 % range 0.01 % rd + 0.003 % range 0.01 % rd + 0.003 % range 0.012 % rd + 0.003 % range 0.022 % rd + 0.032 % range 0.01 % rd + 0.017 % range 0.007 % rd + 0.012 % range 0.01 % rd + 0.017 % range 0.007 % rd + 0.012 % range HV & LV outputs – voltage Source Imax, continuous 0.1 % rd + 0.023 % range 0.037 % rd + 0.026 % range 0.008 % rd + 0.01 % range Combined values HV & LV outputs – current Source Vmax, continuous 0.1 % rd + 0.18 % range 0.1 % rd + 0.267 % range 0.1 % rd + 0.18 % range 0.037 % rd + 0.017 % range 0.04 %...

 Open the catalog to page 10
TESTRANO 600-Three-phase test system for comprehensive power and distribution transformer testing-11

Power specifications Voltage Power fuse Automatic circuit breaker with magnetic overcurrent tripping at I > 16 A Capacitance Cp (equivalent parallel circuit) Power consumption Environmental conditions Temperature Relative humidity Maximum altitude Operating: Storage: Dissipation factor DF (tan δ) Range Mechanical data Dimensions (W × H × D) Device with display: Device without display: IEC / EN 60068-2-27, 15 g / 11 ms, half-sinusoid, each axis IEC / EN 60068-2-6, frequency range from 10 Hz to 150 Hz, continuous acceleration 2 g (20 m /s2 / 65 ft /s2), 10 cycles per axis Typical accuracy 3 Error...

 Open the catalog to page 11

All OMICRON electronics catalogs and technical brochures

  1. MCT 085

    2  Pages

  2. PDL 650

    8  Pages

  3. CPC 100

    44  Pages

  4. InSight

    4  Pages

  5. MONTESTO 200

    16  Pages

  6. ISIO 200

    8  Pages

  7. CMControl R

    12  Pages

  8. CMControl P

    8  Pages

  9. CMS 356

    2  Pages

  10. IEDScout

    8  Pages

  11. CMA 156

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.