CPC 100 - 1

CPC 100 Multi-functional primary test system for substation commissioning and maintenance

Open the catalog to page 1
CPC 100 - 2

CPC 100 – The revolutionary all-in-one test system The patented test system replaces numerous individual testing devices and offers new, innovative testing methods. This makes testing with the CPC 100 a timesaving and cost-effective alternative for conventional testing methods. Despite its expansive capabilities, the CPC 100 is very simple to use. Turns ratio meter for transformers, CTs and VTs The powerful testing device provides up to 800 A or 2 kV (2 kA or 12 kV with accessories) with up to 5 kVA over a frequency range of 15 Hz to 400 Hz or 400 ADC. Its compact design (29 kg / 64 lbs)...

Open the catalog to page 2
CPC 100 - 3

Ground resistance meter Micro ohmmeter 400 ADC Tester for Rogowski coils and other unconventional CTs / VTs (IEC 61850) single phase wall outlet Winding resistance meter Protection relay tester (one phase V, I, f) 800 AAC 2 kA (with booster) Step up transformer 2 000 V Complex impedance meter (burdens, cables, lines and transformers) Vector group verification system for power transformers Polarity checker Power / dissipation factor measurement set 3

Open the catalog to page 3
CPC 100 - 4

9 good reasons for one system >> Test several assets (e.g. CT, VT, CB, power transformer) >> Test different parts of an asset (e.g. core, windings, bushing, insulation) >> Perform numerous tests >> Voltage and current injection with variable frequency (e.g. ratio, polarity, burden, excitation current) >> Suppression of mains-related interference and disturbances >> Test results at different frequencies provide more detailed information about an asset >> Variable frequency testing is necessary for some standardized and advanced diagnostic tests >> Offline test preparation possibilities...

Open the catalog to page 4
CPC 100 - 5

>> Durable case design for rough environments with test field accuracy >> Long lifetime due to high quality components >> Premium quality cables and clamps >> Comprehensive documentation (e.g. user manual with connection diagrams, software help function, videos, application notes) >> Further applications can be covered by adding additional hardware accessories >> By upgrading the software: > Additional tests can be performed > Additional assets can be tested >> Emergency switch-off button >> Protective Earth conductor connection check >> Overload detection >> Multiple isolated outputs >>...

Open the catalog to page 5
CPC 100 - 6

CPC 100 product family – Extended range of applications The CPC 100 covers a lot of different applications in and around substations as well as at the manufacturer’s production site. Extended by a high number of valuable accessories the application range of the CPC 100 is further expanded. Thus it is the ideal instrument for all major applications in the area of primary testing. CPC 100 Applications Current transformer testing (page 8 – 9) Voltage transformer testing (page 10 – 11) Power and distribution transformer diagnosis (page 12 – 13) Grounding system analysis (page 16 – 17)...

Open the catalog to page 6
CPC 100 - 7

Extended range with accessories HV cable and power line analysis (page 14 – 15) Grounding box Grounding system analysis (page 16 – 17) Coupling unit Handheld grounding tester Remote control Power and distribution transformer diagnosis (page 12 – 13) Switchgear / circuit breaker testing (page 22 – 23) Rotating machine diagnosis (page 18 – 19) Compensation reactor Voltage transformer testing (page 10 – 11) Tan Delta test set (power factor) Current transformer testing (page 8 – 9) Sampled Values testing (page 26 – 27) Current booster Gas Insulated Switchgear testing (page 20 – 

Open the catalog to page 7
CPC 100 - 8

Current transformer (CT) testing Why testing CTs? Testing current transformers helps to detect installation related and in-service related problems, such as: Supplied from a single phase wall outlet, the CPC 100 can generate up to 800 A AC (2 000 A with CP CB2 current booster) for injecting into the CT‘s primary side and testing its ratio, polarity and burden. Installation related Excitation curve measurement For excitation curve measurement, the CPC 100‘s output is connected to the secondary terminals of the core. Within an automatic test run, the CPC 100 measures the excitation curve and...

Open the catalog to page 8
CPC 100 - 9

Winding resistance measurment Current transformer testing Using the winding resistance measurement function also allows the user to calculate the accuracy limiting factor (ALF) for protection circuits and the instrument security factor (FS) for metering circuits. >> CT ratio (with burden)   up to 800 A or 2 000 A with CP CB2, 5 kVA output power Power/dissipation factor (PF/DF) measurement When combined with the CP TD12/15, the CPC 100 is also capable of performing PF/DF measurements. This helps to assess the insulation condition of the CT. (knee point) up to 2 kVAC >> Polarity check with...

Open the catalog to page 9
CPC 100 - 10

Voltage transformer (VT) / potential transformer testing Why testing VTs? The majority of VT failures occur due to electrical stresses or manufacturing and installation errors. Typically electrical stresses are caused by: With a voltage output of up to 2 000 VAC the CPC 100 can be used to test VT ratio, polarity and burden. By injecting voltage into the primary side, ratio can be measured. Thereby the phase angles of high-voltage output and voltage measurement input are also measured. Thus the correct VT polarity can be verified. >> Thunderstorms >> Ferro-resonances effects >> Over-voltages...

Open the catalog to page 10
CPC 100 - 11

Disturbance-free measurement Voltage/potential transformer testing The VT‘s secondary signal may be difficult to measure if it is small in amplitude – especially if neighboring parts of the substation are in operation. In case of strong disturbances, the user can select a frequency different to that of the power system and utilizes the “frequency selective measurement” function. Thus only the VT‘s output signal with this particular frequency is measured while all other signals are filtered out. >> VT ratio  up to 2 kVAC | polarity and burden >> VT secondary voltage withstand test  up to 2...

Open the catalog to page 11