video corpo

F 0700

F 0700

Product catalog summary

Technical Data Sheet Overview

This document provides detailed technical specifications for a filtration system model F0700 HDT, focusing on various filter types and their performance parameters.

1. Filter Models and Types

  • QF - Dust Filtration
  • PF - General Purpose Protection Filtration
  • High Temperature Filters

Specific filter codes include 04E.4200.Q, 04E.4200.P, 04E.4200.H, 04G.4200.PG00, and 04G.4200.HG00.

2. Filtration Capacity and Flow Rates

  • Filter capacity: 70000 l/min (4200 m³/h)
  • Flow rates are specified at 7 bar and 20°C.

3. Working Pressure and Connections

  • Working pressure: 7 bar nominal, with a maximum of 16 bar.
  • Air connections: DN125 BSP.

4. Filtration Performance and Standards

  • Maximum solid particle size intercepted according to ISO 8573-1: ranges from 1 µm to 0.01 µm depending on filter type.
  • Filtration process: physical interception, interception combined with coalescing for oil removal.
  • Remaining oil content after filtration (ISO 12500-1): from 0.6 mg/m³ down to 0.01 mg/m³ depending on filter class.
  • Filtration classes: 3, 2, and 1 corresponding to different filtration grades.

5. Operational Parameters

  • Maximum temperature: 150°C.
  • Pressure drop with new element: 0.05 to 0.4 bar depending on filter type.
  • Pressure drop with saturated elements: 0.4 bar.
  • Element replacement interval: 4000 hours or approximately 6 months.

6. Physical Dimensions and Weight

  • Dimensions: 1250 mm length, 150 mm diameter.
  • Net weight: ranges from 280 kg to 670 kg depending on filter type.

7. Correction Factors for Line Pressure

Correction factors are provided for line pressures ranging from 1 to 16 bar, with values from 0.38 to 1.51 to adjust performance parameters accordingly.

8. Additional Notes

  • Standard type of drain and filtration grade details are included but not fully specified in the excerpt.
  • Complete filter code example: 04G.4200.QG00.

Summary: This technical sheet defines the specifications, operational limits, and maintenance intervals for high-efficiency oil removal and dust filtration systems, ensuring compliance with ISO standards for particle and oil content filtration. It provides critical parameters for selecting appropriate filters based on application requirements, pressure conditions, and temperature limits.

See more

Catalog excerpts

F 0700-1

TECHNICAL DATA SHEET Rev.00 - 24/11/2015 High Temperature Filters MODEL F0700 HDT l/min 70000 Filter capacity Working pressure Air connections Net weight Standard type of drain Flow rates at 7 bar and 20°C QF - Dust Filtration PF - General purpose Protection Filtration HF - High Efficiency Oil Removal Filtration

 Open the catalog to page 1

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.