video corpo

Chiller catalogue

Chiller catalogue
1 / 20 PagesView full catalog

Chiller catalogue

Product catalog summary
Overview
The document provides comprehensive information on liquid chillers and coolers designed for industrial applications, focusing on the CHW, CHG, CHO, CHR, and CHA series. It highlights their specifications, applications, and available options.
Quality and Standards
The company adheres to ISO 9001, ISO 14001, and OHSAS 18001 standards, ensuring high performance and technological advancement in their products.
CHW Series - Water Chillers
These mono-block refrigerators are suitable for internal and external installations, equipped with a pump and tank, and are used in industries like welding and food packaging.
CHG Series - Low Temperature Water Chillers
Designed for the chemical and food industries, these chillers operate with outlet water temperatures below 0°C using refrigerant gas R404a.
CHO Series - Oil Chillers
This series provides efficient cooling solutions for machinery with hydraulic cooling, such as precision tooling machinery.
CHR Series - Air to Water Coolers
Suitable for applications requiring liquid cooling at temperatures not lower than ambient, utilizing forced air from fans.
Available Options
Options include non-standard voltages, automatic by-pass, non-ferrous pumps, and precision control. Additional options include low ambient temperature kits and water level alarms.
Technical Specifications
Detailed tables list models, cooling capacities, power consumption, dimensions, and weights for each series, along with standard reference conditions and operating temperatures.
Specifications
Models in the CHR and CHA series are detailed with specifications like cooling capacity and power supply. For example, the CHR 17 model has a cooling capacity of 17.9 kW.
Standard Reference Conditions
Ambient temperature: 20°C, Fluid outlet temperature: 25°C, Fluid type: H2O.
Operating Temperatures
Fluid temperature range: +5°C to +55°C, Ambient temperature range: +2°C to +40°C.
Accessories
Accessories such as remote displays and flow switches can be added post-purchase, subject to compatibility checks.
Correction Factors
Correction factors adjust the nominal cooling capacity based on ambient and fluid outlet temperatures, with recommendations to consult the manufacturer for precise adjustments.
Applications
Suitable for cooling welders, spindles, and other industrial applications, with or without a pump and tank, and can be paired with energy-saving chillers for free-cooling applications.
Graphical Data
A graph shows the relationship between ambient temperature and correction factors, with temperatures ranging from 15°C to 55°C.
Application Examples
Applications include laser work centers, ozone generators, plastic extrusion, and PET bottling.
Contact Information
Contact details for Officine Meccaniche Industriali are provided, including their address in Italy, phone, fax, website, and email.
Disclaimer
OMI reserves the right to change the data without prior notice.
See more

Catalog excerpts

Chiller catalogue-1

ISO toot ISO 14001 ftSOHSAS (tool CvMM Inligrolwl SytHKni CHW - CHG - CHO - CHR - CHA SERIES LIQUID CHILLERS AND COOLERS REFRIGERATORI FINALI AD ACQUA O AD ARIA

 Open the catalog to page 1
Chiller catalogue-2

Liquid refrigeration / Refrigerazione di liquidi Liquid chillers and coolers / Refrigeratori e raffreddatori di liquido Chillers & liquid coolers Refrigeratori e raffreddatori di liquido The continuous growth of the market, and the experience developed in the field has taken us to revise the whole range of our products with the declared aim of being the referring quality point of the sector. The possibility to fill the whole range of products with the development of aiming solutions allow us to reach high level performances and reliability. The adaptation of the quality system in accordance with...

 Open the catalog to page 2
Chiller catalogue-3

STANDARD REFERENCE CONDITIONS • Ambient temperature: 25 °C • Fluid outlet temperature: 15° C • Fluid type: H2O OPERATING TEMPERATURES • Fluid temperature: +0°C /+25°C (min/max) • Ambient temperature: +15°C /+40°C (min/max) CONDIZIONI STANDARD DI RIFERIMENTO: • Temperatura ambiente: 25 °C • Temperatura uscita liquido: 15° C • Tipo fluido: H2O TEMPERATURE OPERATIVE • Temperatura fluido: +0°C / +25°C (min/max) • Temperatura ambiente: +15°C / +

 Open the catalog to page 3
Chiller catalogue-4

CHW 29 - 149Water chillers / Refrigeratori d’acqua AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Low ambient temperature kit. • Water level alarm. • Precision +/- 0,5°K. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Kit bassa temperatura ambiente. • Allarme di livello elettrico. • Precisione +/- 0,5°K. Mono-block refrigerators for internal installation, supplied...

 Open the catalog to page 4
Chiller catalogue-5

CHW 162 - 1202Water chillers / Refrigeratori d’acqua AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Low ambient temperature kit. • Water level alarm. • Precision +/- 0,5°K. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Kit bassa temperatura ambiente. • Allarme di livello elettrico. • Precisione +/- 0,5°K. Mono-block refrigerators for internal and external use...

 Open the catalog to page 5
Chiller catalogue-6

CHW 1452 - 3652Water chillers / Refrigeratori d’acqua AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Low ambient temperature kit. • Water level alarm. • Precision +/- 0,5°K. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Kit bassa temperatura ambiente. • Allarme di livello elettrico. • Precisione +/- 0,5°K. Mono-block refrigerators for internal and external use...

 Open the catalog to page 6
Chiller catalogue-7

CHG 08 - 100Low temperature water chillers / Refrigeratori d’acqua per basse temperature AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Low ambient temperature kit. • Water level alarm. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Kit bassa temperatura ambiente. • Allarme di livello elettrico. The low temperature liquid water chillers were designed to meet the...

 Open the catalog to page 7
Chiller catalogue-8

CHG 140 - 365Low temperature water chillers / Refrigeratori d’acqua per basse temperature AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Low ambient temperature kit. • Water level alarm. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Kit bassa temperatura ambiente. • Allarme di livello elettrico. The low temperature liquid water chillers were designed to meet...

 Open the catalog to page 8
Chiller catalogue-9

STANDARD REFERENCE CONDITIONS • Ambient temperature: 25 °C • Fluid outlet temperature: 20° C • Fluid type: Oil ISO VG 32 OPERATING TEMPERATURES • Fluid temperature: +20°C /+30°C (min/max) • Ambient temperature: +2°C / +40°C (min/max) CONDIZIONI STANDARD DI RIFERIMENTO: • Temperatura ambiente: 25 °C • Temperatura uscita liquido: 20° C • Tipo fluido: Olio ISO VG 32 TEMPERATURE OPERATIVE • Temperatura fluido: +20°C / +30°C (min/max) • Temperatura ambiente: +2°C / +40°C (min/ma

 Open the catalog to page 9
Chiller catalogue-10

CHR 0.8 - 10Air to water coolers / Raffreddatori d'acqua ad aria AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. Air water liquid coolers, equipped with pump and tank, are suitable for cooling welders and spot welders, spindle, and for all industrial applications that require liquid cooling at temperature not lower than...

 Open the catalog to page 10
Chiller catalogue-11

CHR 17 - 54Air to water coolers / Raffreddatori d’acqua ad aria AVAILABLE OPTIONS • Non-standard voltages: all models are available with 60 Hz voltage. • Automatic by-pass and manometer. • Non-ferrous 4 or 6 bar pump. • Water level alarm. OPZIONI DISPONIBILI • Voltaggi fuori standard: tutti i modelli sono disponibile in versione 60Hz. • By-pass automatico interno e manometro. • Pompa a 4 o 6 bar non ferrosa. • Allarme di livello elettrico. Air water liquid coolers, equipped with pump and tank, are suitable for cooling welders and spot welders, spindle, and for all industrial applications that...

 Open the catalog to page 11

All OMI Officine Meccaniche Industriali catalogs and technical brochures

  1. ESD catalogue

    7  Pages

  2. F 0700

    1  Page

  3. EPL catalogue

    8  Pages

  4. ED catalogue

    10  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.