Product catalog summary
Overview: The document provides detailed specifications and ordering information for the WMS-20 Series wind monitor stations, which include models WMS-21, WMS-23, and WMS-23S. These devices are designed for monitoring wind speed and direction, with options for dry contact alarms or analog outputs.
Specifications:
  • WMS-21: Dual setpoint wind station with a measurement range of 0 to 100 mph, using a reed switch transducer. It features a threshold speed of 0.8 mph and measurement accuracy of 1 mph or 3%. The device includes a protected push-button for setting variables and alarm values, with an alarm on/off delay range of 0 to 99 seconds. It operates at a supply voltage of 12 Vac or Vdc and a current of 50 mA. The operating temperature range is -20 to 50ºC.
  • WMS-23 and WMS-23S: These models monitor wind speed and direction (WMS-23) or wind speed only (WMS-23S). They have a measurement range of 0 to 100 mph, with a threshold speed of 0.8 mph and accuracy of 1 mph or 3%. The WMS-23 also measures wind direction with an azimuth accuracy of ±3% and a mechanical range of 0 to 360°.
Ordering Information:
  • WMS-21: $725
  • WMS-23S: $675
  • WMS-23: $730
  • WMS-EC-40 (12 m extension cable): $40
Features: The WMS-21 includes an LCD display for wind speed readout and setpoint adjustments, with self-contained relays for external device actuation. The WMS-23 series converts parameters into a 4 to 20 mA signal for integration with process controllers or monitoring systems.
Additional Products: The document also mentions a wide range of related products available, including calibrators, temperature measurement instruments, pressure sensors, flowmeters, and data acquisition systems.
See more

Catalog excerpts

Wind Monitoring Station with Analog Outputs  WMS-20 Series-1

Hu-65 Comes with sensor cable and operator’s manual. Ordering Example: WMS-23, wind speed/direction wind station with 4 to 20 mA output and cable, $730, and WMS-EC-40, 12 m (40') extra extension cable, $40, $730 + 40 = $770. Specifications WMS-21 Wind Speed Measurement Range: 0 to 100 mph Transducer Type: Reed switch Avg Speed Resolution: 0.1 mph Threshold Speed: 0.8 mph Measurement Accuracy: 1 mph or 3% To Order (Specify Model Number) Model No. Price Description WMS-21 $725 Dual setpoint wind station WMS-23S 675 Wind speed only 4 to 20 mA output WMS-23 730 Wind speed/direction 4 to 20 mA output WMS-EC-40 40 12 m (40') extension cable Controls: Protected push-button for run, or set variables, select menu items, increment and decrement alarm values Alarm On/Off Delay Range: 0 to 99 sec Contact Ratings: 3 A SPDT @ 24 Vdc Display: 2 line x 16 character LCD Character Size: 3 x 8 mm Setpoint 1 and 2: LED Supply Voltage: 12 Vac or Vdc Supply Current: 50 mA, 5 mA nominal Operating Temperature: -20 to 50ºC (-4 to 122°F) Dimensions: Anemometer: 114.3 H x 215.9 W mm (4.5 x 8.5") Sensor Cable Length: 12 m (40'), supplied Electronics Enclosure Size: 119.3 H x 198.1 W x 88.9 D mm (4.7 x 7.8 x 3.5") WMS-23 (Wind Speed and Direction) WMS-23S (Wind Speed) Measurement Range: 0 to 100 mph Transducer Type: Reed switch Threshold Speed: 0.8 mph Measurement Accuracy: 1 mph or 3% WMS-23 Only (Wind Direction) Azimuth Accuracy: ± 3% Mechanical Range: 0 to 360° Potentiometer Gap: 5° Threshold: 1.2 mph Measurement Range: 0 to 360° Current Loop: Output Span: 4 to 20 mA Proportioned: 0 to 100 mph, 0 to 360º Circuit Time Constant: 1 sec 2-Wire Loop Interface: Screw terminal block Supply Voltage: 8 to 30 Vdc Operating Temperature: -40 to 40ºC (-40 to 104ºF) Dimensions: Anemometer and Vane: 305 H x 254 W mm (12 x 10") Anemometer Only: 114.3 H x 215.9 W mm (4.5 x 8.5") Sensor Cable Length: 12 m (40'), supplied Electronics Enclosure Size: 114.3 H x 114.3 W x 63.5 D mm (4.5 x 4.5 x 2.5") WMS-21, dual setpoint wind station, $690, shown smaller than actual size. Wind Monitor Stations with Dry Contact Alarm or Analog Outputs The WMS-20 Series consist of 3 individual wind monitor stations. The WMS-21 is a microprocessorbased wind alarm station. It sounds an alarm buzzer and controls the operation of 2 electrical circuits whenever wind speed reaches either of 2 independent setpoints. An LCD display provides a readout of the measured wind speed and is also used to set the value of the setpoints which are stored in nonvolatile memory. Self-contained relays for each alarm point can be used to actuate external devices such as air samplers or sirens. The WMS-23 Series monitors wind speed and direction. Two versions are offered; WMS-23S measures wind speed only, while the WMS-23 measures both wind speed and direction. Each parameter is converted into a 4 to 20 mA signal for use by process controllers or monitoring systems. WMS-23, wind speed and direction module, $730, shown smaller than actual size. WMS-23S, wind speed and direction module, $675, shown smaller than actual size. MOST POPULAR MODELS HIGHLIGHTED! WMS Series Starts at $675

 Open the catalog to page 1

All OMEGA catalogs and technical brochures

  1. WTS Series

    4  Pages

  2. DPG280

    2  Pages

  3. OMPBD7 series

    6  Pages

  4. Model H

    1  Page

  5. HHAQ-104

    1  Page

  6. DOTX441

    1  Page

  7. TXDIN1600s

    2  Pages

  8. M12

    1  Page

  9. AHPF Series

    1  Page

  10. RFH Series

    2  Pages

  11. HHM10

    6  Pages

  12. RDXL8

    2  Pages

  13. FD-400 Series

    4  Pages

  14. OS-MINIHUB

    4  Pages

  15. RHCM-40-PL-P

    2  Pages

  16. CSMSTRLE

    3  Pages

  17. AU-PTV Series

    3  Pages

  18. ADAM-5000

    7  Pages

  19. KE Series

    1  Page

  20. SRM Series

    3  Pages

  21. SRL Series

    3  Pages

  22. PHH-SD1

    2  Pages

  23. PHH222

    1  Page

  24. PHH224

    1  Page

  25. PHH720

    1  Page

  26. PHH830

    2  Pages

  27. PHH-126

    1  Page

  28. PHH-127

    1  Page

  29. PHH-128

    1  Page

  30. PHH-37

    1  Page

  31. PHH-715

    2  Pages

  32. PHH103B

    1  Page

  33. BB-5

    2  Pages

  34. BB-2A

    2  Pages

  35. CA 150

    5  Pages

  36. CL 110

    2  Pages

  37. CL 1600

    2  Pages

  38. CL 1201

    2  Pages

  39. CL 355A

    2  Pages

  40. FL 500

    2  Pages

  41. FL 500WW

    2  Pages

  42. FL-X

    2  Pages

  43. FPR 100

    3  Pages

  44. FSW500

    2  Pages

  45. FSW 420- 430

    2  Pages

  46. CDTX90

    6  Pages

  47. FSW 6000-7000

    3  Pages

  48. DRP 8500

    3  Pages

  49. DP 3300

    2  Pages

  50. DP119

    1  Page

  51. HE-X Series

    3  Pages

  52. HE359 Series

    3  Pages

  53. RD4

    2  Pages

  54. DPi

    3  Pages

  55. HH311

    2  Pages

  56. MP1

    1  Page

  57. HFS

    2  Pages

  58. CO

    2  Pages

  59. WT

    2  Pages

Archived catalogs

  1. 6M Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.