Vapor- and Gas-Actuated Thermometers-1

Vapor- and Gas-Actuated Thermometers T-VA/Line Dwg U ccuracy ±1 Scale A Division or 1% Scale for Gas U rass Movement with B Precision Gearing U hite Dial W with Black Graduations U Phosphor Bronze T-VA/Line Bourdon Tube Dwg OMEGA® remote vapor- and gas-actuated thermometers are manufactured to the highest standards for a wide range of uses and can be CASE AnD MounTInG DIMEnSIonS fitted into almost any temperatureindicating application. These Case and Mounting Dimensions Specifications instruments are ideal for remote Dial Sizes: 2, 2 ⁄ , 3 ⁄ , 4 ⁄ " reading, such as panel installations, FRonT FLAnGE u-CLAMP Dial: Aluminum with white finish and I with capillary lengths of 1 to 100'. black markings D Vapor, or more precisely vaporized G Pointer: Furnished standard adjustable liquid, thermometers will give Movement: excellent readings, provided the E A E B CASE AnD MounTInG DIMEnSIonS Brass with precision gearing 30ϒ temperature being measured is 30ϒ Bourdon Tube: above or below ambient temperature. Vapor-phosphor bronze Vapor instruments also have F F Gas: Nitrogen in nispan coil progressive graduations and are FRonT FLAnGE REAR FLAnGE u-CLAMP Accuracy: best read in the upper 2⁄3 of the dial I I Vapor: ±1 scale division D range. Many ranges are available G Gas: ±1% of scale between -40 to 232°C (-40 to 450°F), Process Connection: Plain bulb, and care should be taken to select A E E B ⁄ NPT union; or C thermowell H a range that will MounTInG operating 30ϒ CASE AnD locate the DIMEnSIonS Note: thermowells must be used 2 30ϒ temperatures within the upper ⁄3 of whenever the bulb would be the dial range. F F 1 OMEGA® gas-actuated thermometers u-CLAMP combine advanced gas coil technology with a state-of-the-art gas absorbent (Class IV) thermal system, producing a superior temperature measurement A E B instrument that can be fitted to a wide variety of applications. Gas-actuated thermometers have an advantage F over vapor-actuated thermometers in that they are more accurate over the full range. They also operate at higher and lower ranges than vapor-actuated thermometers. The linear dial on all OMEGA® gas thermometers provides a consistent 1% accuracy across the full span of each range. This, combined with over 20 Fahrenheit and dual ranges, from -196 to 649°C (-320 to 1200°F), provides complete coverage of all normal temperature requirements. Dial Size exposed to pressure, fluid velocity, F or corrosive media Window: Polycarbonate STD; glass available on all models Bulb: Stainless steel or copper; bulb OD 3⁄8" on plain bulbs, 7⁄16" with threads. Bulb lengths from 21⁄2 to 77⁄8" depending on capillary length Capillary: Copper, copper with bronze braid armor; stainless steel with stainless steel armor; capillary lengths 1 to 100' (standard length, 5') E

 Open the catalog to page 1
Vapor- and Gas-Actuated Thermometers-2

Front flange (panel mount) Rear flange (surface mount) Table 1: Case Style Front Flange (Panel Mount) Code Dial Case 20FR 2" Stainless steel 25FR 21⁄2" Stainless steel 35FR 31⁄2" Stainless steel 45FR 41⁄2" Stainless steel 45FL 41⁄2" Black aluminum (hinge ring type) U-Clamp (Panel Mount) 20UR 2" Stainless steel 25UR 21⁄2" Stainless steel 35UR 31⁄2" Stainless steel Rear flange (Surface Mount) 20RR 2" Stainless steel 35RR 31⁄2" Stainless steel 35RB 31⁄2" Stainless steel 45RR 41⁄2" Stainless steel 45RB 41⁄2" Stainless steel 45TB 41⁄2" Phenolic Lens* Polycarbonate* Polycarbonate* Polycarbonate* Polycarbonate*...

 Open the catalog to page 2
Vapor- and Gas-Actuated Thermometers-3

Thermowells for Vapor- and Gas-Actuated Bulbs (except M2) ⁄ NPT 1 Description 1 to 10' Capillary (bulb #1) To Order Visit omega.com/va_ga_gas_thermom for Pricing and Details Construct a Model Number as Follows - See 3 Examples Below: Case Style Temperature Capillary and Capillary Process and Size Range Bulb Length (feet) Connection

 Open the catalog to page 3

All OMEGA catalogs and technical brochures

  1. WTS Series

    4  Pages

  2. DPG280

    2  Pages

  3. OMPBD7 series

    6  Pages

  4. Model H

    1  Page

  5. HHAQ-104

    1  Page

  6. DOTX441

    1  Page

  7. TXDIN1600s

    2  Pages

  8. M12

    1  Page

  9. AHPF Series

    1  Page

  10. RFH Series

    2  Pages

  11. HHM10

    6  Pages

  12. RDXL8

    2  Pages

  13. FD-400 Series

    4  Pages

  14. OS-MINIHUB

    4  Pages

  15. RHCM-40-PL-P

    2  Pages

  16. CSMSTRLE

    3  Pages

  17. AU-PTV Series

    3  Pages

  18. ADAM-5000

    7  Pages

  19. KE Series

    1  Page

  20. SRM Series

    3  Pages

  21. SRL Series

    3  Pages

  22. PHH-SD1

    2  Pages

  23. PHH222

    1  Page

  24. PHH224

    1  Page

  25. PHH720

    1  Page

  26. PHH830

    2  Pages

  27. PHH-126

    1  Page

  28. PHH-127

    1  Page

  29. PHH-128

    1  Page

  30. PHH-37

    1  Page

  31. PHH-715

    2  Pages

  32. PHH103B

    1  Page

  33. BB-5

    2  Pages

  34. BB-2A

    2  Pages

  35. CA 150

    5  Pages

  36. CL 110

    2  Pages

  37. CL 1600

    2  Pages

  38. CL 1201

    2  Pages

  39. CL 355A

    2  Pages

  40. FL 500

    2  Pages

  41. FL 500WW

    2  Pages

  42. FL-X

    2  Pages

  43. FPR 100

    3  Pages

  44. FSW500

    2  Pages

  45. FSW 420- 430

    2  Pages

  46. CDTX90

    6  Pages

  47. FSW 6000-7000

    3  Pages

  48. DRP 8500

    3  Pages

  49. DP 3300

    2  Pages

  50. DP119

    1  Page

  51. HE-X Series

    3  Pages

  52. HE359 Series

    3  Pages

  53. RD4

    2  Pages

  54. DPi

    3  Pages

  55. HH311

    2  Pages

  56. MP1

    1  Page

  57. HFS

    2  Pages

  58. CO

    2  Pages

  59. WT

    2  Pages

Archived catalogs

  1. 6M Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.