Smart Powered Strain Bridge/ Load Cell Conditioner-1

Smart Powered Strain Bridge/ Load Cell Conditioner TXDIN1600s ߜ Suitable for load cell / strain gauge applications ߜ Universal current, bipolar voltage outputs ߜ Input range (0.2 to 7.5) mv/v, 5 v excitation ߜ Powered ( 10 to 32) v ac or (10 to 48) v dc supply ߜ (2 to 6) point calibration with active set option ߜ Remote tare, front panel push button configuration ߜ USB programmable The TXDIN1600s is a “smart” powered bridge amplifier for use with strain gauges or load cell signals. The product has a built in capability to scale the input signal to a process value while the output stage offers either voltage, bipolar voltage or active / passive current re-transmission signals. The TXDIN1600s requires an AC/DC power supply that will operate in the range (10 to 48) V DC and (10 to 32) V AC making the device ideal for battery operation. An additional volt free contact input is available for tare setting using a remote switch. The high precision input stage of the device allows for a bridge excitation voltage of 5V DC to be used as opposed to the traditional 10V DC. This reduces the power requirement for the bridge supply and up to four bridges (cells) may be connected to the input. The device is provided with two front panel push buttons that can be configured to perform one of two functions or be disabled. Set as function 1, the buttons allow the user to push button configure the output range at high and low scale against a live input signal, set as function 2, the buttons allow the operator to trim the output at high and low scale. The device uses ratio metric measurement to obtain high stability. The product uses a USB port for configuration, together with a simple to use menu driven software configuration tool, allowing the user to take advantage of the product’s comprehensive specification. Additionally, the user may read live process data when connected to the PC, allowing for offset and span calibration. If configuration is not specified at the time of order, the product will be shipped with the default range 2 mV/V input (4 to 20) mA output. PRESSURE, STRAIN

 Open the catalog to page 1
Smart Powered Strain Bridge/ Load Cell Conditioner-2

Specifications BRIDGE INPUT Full Range: (-7.6 to 7.6) mv\V (-38 to 38) mV @ 5V excitation Type: Four Wire radiometric Drift: < ± 0.05 % Linearity: ± 0.01 % Update: Selectable, 10 or 80 SPS (Samples per second) BRIDGE EXCITATION Voltage: 5 Volts DC ± 0.1 V @ 59 mA Bridge Impedance: Total (85 to 10000) Ω (operates with four 350 Ω cell in parallel) TARE INPUT Type: Remote volt free contact, up to 10 metres distance OUTPUT CURRENT Current Source: Range (0 to 21.5) mA , Max Load 750 Ω Current Sink: Range (0 to 21.5) mA , Supply (10 to 30) V dc, Voltage effect 0.2 uA/V Accuracy: (mA Out/ 2000) or 5...

 Open the catalog to page 2

All OMEGA catalogs and technical brochures

  1. WTS Series

    4  Pages

  2. DPG280

    2  Pages

  3. OMPBD7 series

    6  Pages

  4. Model H

    1  Page

  5. HHAQ-104

    1  Page

  6. DOTX441

    1  Page

  7. TXDIN1600s

    2  Pages

  8. M12

    1  Page

  9. AHPF Series

    1  Page

  10. RFH Series

    2  Pages

  11. HHM10

    6  Pages

  12. RDXL8

    2  Pages

  13. FD-400 Series

    4  Pages

  14. OS-MINIHUB

    4  Pages

  15. RHCM-40-PL-P

    2  Pages

  16. CSMSTRLE

    3  Pages

  17. AU-PTV Series

    3  Pages

  18. ADAM-5000

    7  Pages

  19. KE Series

    1  Page

  20. SRM Series

    3  Pages

  21. SRL Series

    3  Pages

  22. PHH-SD1

    2  Pages

  23. PHH222

    1  Page

  24. PHH224

    1  Page

  25. PHH720

    1  Page

  26. PHH830

    2  Pages

  27. PHH-126

    1  Page

  28. PHH-127

    1  Page

  29. PHH-128

    1  Page

  30. PHH-37

    1  Page

  31. PHH-715

    2  Pages

  32. PHH103B

    1  Page

  33. BB-5

    2  Pages

  34. BB-2A

    2  Pages

  35. CA 150

    5  Pages

  36. CL 110

    2  Pages

  37. CL 1600

    2  Pages

  38. CL 1201

    2  Pages

  39. CL 355A

    2  Pages

  40. FL 500

    2  Pages

  41. FL 500WW

    2  Pages

  42. FL-X

    2  Pages

  43. FPR 100

    3  Pages

  44. FSW500

    2  Pages

  45. FSW 420- 430

    2  Pages

  46. CDTX90

    6  Pages

  47. FSW 6000-7000

    3  Pages

  48. DRP 8500

    3  Pages

  49. DP 3300

    2  Pages

  50. DP119

    1  Page

  51. HE-X Series

    3  Pages

  52. HE359 Series

    3  Pages

  53. RD4

    2  Pages

  54. DPi

    3  Pages

  55. HH311

    2  Pages

  56. MP1

    1  Page

  57. HFS

    2  Pages

  58. CO

    2  Pages

  59. WT

    2  Pages

Archived catalogs

  1. 6M Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.