100 and 180 mm Programmable Chart Recorders RD200 and RD2800 Series Starts at $1430 Simultaneous Digital Displays of Multipoint Data Universal Input Alarm Display/Printings Software Package “KIDS” Available Conforms to CE, UL, and CSA Standards The RD200 and RD2800 Series chart recorders are 100 mm, multipoint, hybrid recorders that can print/display multichannel and alarm data simultaneously. A total of 56 ranges can be programmed for each channel: 35 thermocouple, 11 RTD, and 10 DC voltage. The user can also program up to 4 levels of alarms for each channel; optional alarm outputs are available. The recorders display alarm settings (status and channels), and can print channel alarms and alarm numbers. A data acquisition software package, “KIDS”, lets the user create real-time and historical data/trend displays. The RD200 and 2800 Series chart recorders are manufactured in ISO9001-certified facilities and conform to CE, UL, and CSA safety standards. Specifications Input Specifications Number of Measuring Points: RD200 Series: Multipoint: 6 points Pen Type: 1 to 4 points RD2800 Series: Multipoint: 6, 12, 24 points Pen Type: 1 to 4 points Input Signals: Universal input, DC voltage, thermocouple, DC current (requires shunt resistor) Contact input [remote-contact input (option— up to 4 points) for operation printing for inputs] Range Setup: Programming of input types and ranges by keys Scale Setup: Programming of maximum value, minimum values, and engineering units by keys Accuracy Rating: Refer to the table of inputs RD206, $1560, shown smaller than actual size. RD2812, $2295, shown smaller than actual size. S-23
Open the catalog to page 1List Printing: Programmed Parameters: Same color as trace printing Others: Black Programming Change Mark: Black Alarm Printing: Red Chart: Fan-fold Chart Speed: 1 to 1500 mm/hr Chart Speed Default: RD200— 20 mm/hr, RD2800—25 mm/hr Periodic Data Printing: Digital printing of time, channel numbers and measured values on trace printing interval time (hour, minute); optional programming (limited by chart speeds) Digital Data Printing: Digital printing of time and measured values by interrupting trace printing on demand Alarm Printing: Alarm-Activated: Time, channel number, alarm type and level...
Open the catalog to page 2Display Specifications (Multipoint) Digital Display: -9999 to 99999 Display Items: Simultaneous display of 6 or 12 measured values per channel, or time(year/month/ day/hour/minute), alarm-activated channel and chart speed Status Display: Printing status, key lock and alarm-activation condition Printing Specifications (Pen-Type) Printing System: Analog Tracing: Disposable cartridge pen Digital Printing: Plotter pen Printing Color: Analog Tracing: 1st pen red, 2nd pen green, 3rd pen blue, 4th pen brown Digital Printing: Purple periodic data printing, digital data printing (analog tracing...
Open the catalog to page 3Pass software, $270. General Specifications Rated Power Supply: 100 to 240 Vac, 50/60 Hz Rated Power Consumption: Multipoint: Max 45 VA Pen-Type: Max 60 VA Normal Operating Conditions: Ambient Temp/Humidity: Multi-Point: 0 to 40°C (32 to 104°F), 20 to 80% RH Pen Type: 0 to 50°C (32 to 122°F), 20 to 80% RH Power Voltage: 90 to 264 Vac Power Frequency: 50/60 Hz ±2% Attitude: Left/right 0 to 10°, forward tilting 0°, backward tilting 0 to 30° Power Failure Protection: Multipoint: Programmed parameters stored in EEPROM memory; clock circuit sustained for minimum 10 years by a lithium battery (at...
Open the catalog to page 4S-27 Options (Pen-Type) Options (Multipoint Type) Options Explanations 1 second/6 points, 2 second/12 points, 4 seconds/24 points; alarm judgment interval: same as measuring interval, multipoint simultaneous display only; printing interval: about 5 seconds/point, Measuring Interval conforming to CE, UL, CSA; the indication equivalent to maximum 25°C or 2 mV may vary under the test environment requested by EMC directive; by signals of 4-point contacts and 2-point common Contacts, the following operations are Remote Contacts executed: selection of 3-chart speed/stop, digital data printing and...
Open the catalog to page 5Dimensions: mm (in) Note: Accuracy ratings are of measuring ranges at reference operation conditions. The reference junction compensation accuracy is not included with the accuracy ratings of thermocouple inputs. The indication equivalent to 200 ìV or 5°C (41°F) may vary under the test environment requested by EMC directive. Reference operating conditions: Ambient Temperature/Humidity Range: 21 to 25°C (70 to 77°F), 45 to 65% RH Power Voltage: 100 Vac ±1% Power Frequency: 50/60 Hz ±0.5% Attitude: Left/right 0°, forward tilting 0°, backward tilting 0° Warm-Up Time: More than 30 minutes 144...
Open the catalog to page 7S-30 S Comes with user’s manual, 1 pen per channel and 1 pack of chart paper. Ordering Example: RD206, 6-point recorder, $1560. Accessories Model No. Price Description RD200-RC $22 6-color ribbon cassette for RD200 RD2800-RC 60 6-color ribbon cassette for RD2800 180A-CP-0-100 12 Chart paper for RD2800 pen (1 pack) RD200-CP-0/100 79 Chart paper for RD200 pen (1 pack) RD2800-PASS 270 Parameter programming software RD2800-KIDS 270 Data acquisition software RD200-01 33 Red pen, 1-channel for RD200 RD200-02 33 Green pen, 2-channels for RD200 RD200-03 33 Blue pen, 3-channels for RD200 RD200-04 33...
Open the catalog to page 8All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
Coriolis Mass Flow Meter
4 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer-PTC_14
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer_PTC 16
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
iDRN/iDRX Series
9 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
OM-DAQPRO-5300
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger
5 Pages