Catalog excerpts
S-15a S Portable Paperless Recorders and Data Acquisition Stations RD-MV1000 and RD-MV2000 Series Starts at $2940 Multi-Channel Universal Inputs, Up to 48 Input Channels Secure High Capacity Memory with Internal Memory of 200 MB Choice of Compact Flash and USB Removable Storage Media Detachable Input Terminals Simplify Field Wiring Advanced Network Connectivity with Email, File Transfer, and Web Server Functions Standard Equipped with 2 USB Ports High Speed Sampling (25 ms for Every Channel) Clear Wide-Angle LCD Monitor Integral Bar Graph Display Application Software (Optional) Compliance with Safety Standards and EMC Standards Isolated Channel Inputs for DC Voltage and Thermocouple Inputs Recorders Can Save Data Files in a Text File Format The RD-MV1000/MV2000 portable paperless recorders are high performance and easy-to-use test instruments that handle a wide range of measurements in your lab, plant, or test stand. These recorders have powerful stand-alone data logging capability. The units record on-site changes in temperature, voltage, current, flow and pressure. The RD-MV1000 features 24 channel-input and RD-MV2000 has 48 channels. Both models feature 200 MB of memory, allowing data to be stored for approximately 70 days at one-second intervals with a 12-channel model. The recorders feature guidance messages for set-up and entering of settings. Measured data can be stored in text format on removable storage media for further processing and data back up on a personal computer using standard software. The RD-MV1000 features a 140 mm (5.5") color TFT-LCD display and the RD-MV2000 has a 264 mm (10.4") display. The RD-MV1000/MV2000 series is a portable recorder that displays real-time measured data on a color LCD and saves data on a Compact Flash memory card (CF card). It can be hooked up to network via Ethernet, which enables to inform by E-mail and to monitor on Web site as well as to transfer files by using FTP. Also, it can communicate with Modbus RTU or Modbus TCP. The data saved on a CF card can be converted by data conversion software to MS-Excel or text format file, facilitating processing on a PC. Not only this, the Viewer software allows a PC to display waveforms on its screen and to print out waveforms. RD-MV2008, $4940, shown RD-MV1006, $2940, shown smaller than actual size. smaller than actual size.
Open the catalog to page 1S-15b General Specifications RD-MV1000 External Dimensions: 189 W x 177 H x 259 D mm (7.4 x 7 x 10.2") Weight: Approx. 3.5 kg (7.7 lb) (MV1024) RD-MV2000 External Dimensions: 307 W x 273 H x 260 D mm (12.1 x 10.7 x 10.2") Weight: Approx. 5.6 kg (12.3 lb) (RD-MV2048) Input Number of Inputs: RD-MV1000: 4, 6, 8, 12, or 24 channels RD-MV2000: 8, 10, 20, 30, 40 or 48 channels Measurement Intervals: RD-MV1004, RD-MV1008, RD-MV2008: 125 ms, 250 ms, or 25 ms in high-speed mode* RD-MV1006, RD-MV1012, RD-MV1024, RD-MV2010, RD-MV2020, RD-MV2030, RD-MV2040, RD-MV2048: 1 s (100 ms not possible for A/D...
Open the catalog to page 2S-15c S Data Formats: When saving to external media, both event data and display data can be saved in either binary or text format (data is always stored to internal memory in binary format) Event Data Sampling Period: RD-MV1004/RD-MV1008/ RD-MV2008: Selectable from 25, 125, 250, 500 ms; 1, 2, 5, 10, 30, 60, 120, 300, 600 s RD-MV1006/RD-MV1012/ RD-MV1024/RD-MV2010/ RD-MV2020/RD-MV2030/ RD-MV2040/RD-MV2048: Selectable from 125, 250 ms; 1, 2, 5, 10, 30, 60, 120, 300, 600 s Trigger Function: Data can be saved using Free mode or Trigger mode Trigger Mode: The user must set the data length,...
Open the catalog to page 3S-15d Normal Operating Conditions Supply Voltage: AC Power Supply: 90 to 132, 180 to 250 Vac DC Power Supply: 10.0 to 28.8 Vdc Supply Frequency: 50 Hz ±2%, 60 Hz ±2% Ambient Temperature: 0 to 40°C (32 to 104°F) Ambient Humidity: 20 to 80% RH @ 5 to 40°C (41 to 104°F) Warm-Up Time: At least 30 minutes Standard Performance Measuring Accuracy: The following specifications apply to operation of the recorder under standard operation conditions Temperature: 23 ±2°C (36°F) Humidity: 55% ±10% RH Power Supply Voltage: 90 to 132 or 180 to 250 Vac Power Supply Frequency: 50/60 Hz ±1% Warm-Up Time: At...
Open the catalog to page 4One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com www.omega.com More than 100,000 Products Available! CANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA UNITED KINGDOM www. omega.co.uk Manchester, England 0800-488-488 GERMANY www.omega.de Deckenpfronn, Germany 0800-8266342 FRANCE www.omega.fr Guyancourt, France 088-466-342 BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44 UNITED STATES www.omega.com 1-800-TC-OMEGA Stamford, CT. CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic 596-311-899 Temperature Calibrators, Connectors, General Test and...
Open the catalog to page 6All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
Coriolis Mass Flow Meter
4 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer-PTC_14
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer_PTC 16
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
iDRN/iDRX Series
9 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
OM-DAQPRO-5300
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger
5 Pages