Portable Handheld Data Logger OM-DAQPRO-5300-UNIV U -Channel Data Logger— 8 Measures Voltage; Current; Pt100 RTD; J, K, T Thermocouples; 2252 Ω or 10 KΩ Thermistors; Frequency/ Pulse Input U larm Output A U 6-Bit Sampling Resolution 1 U ast USB Communications F U apid Sampling—Up to 4000 R Samples/Sec (Single Channel Burst Mode) U arge Data Storage— L 512 KB RAM U raphical Display—Shows G Collected Data as Measured Values, Graphs or Tables U ultiple Logging Sessions— M Stores up to 100 Recording Sessions U owerful Analysis Software P for Windows XP/VISTA/7 The OM-DAQPRO-5300-UNIV is an 8-channel portable data acquisition and logging system with graphic display and built-in analysis functions. The data logger is powered by an internal rechargeable battery and is capable of sampling, processing and displaying measurements without being connected to a computer. Every OM-DAQPRO-5300-UNIV data logger is embedded with a unique serial number and can be loaded with a descriptive comment for safe identification. The data logger is very easy to use because all its functions are broken down into an 8-icon menu. The four buttons on the data logger’s front keypad can be used to browse every menu and execute any of the commands. The OM-DAQPRO-5300-UNIV has eight input channels for measuring voltage, current, temperatureand pulses. User-selectable input types/ranges are 0 to 24 mA, 0 to 50 mV, 0 to 10 V, 2252 Ω or 10 KΩ The OM-DAQPRO-5300-UNIV is a professional, cost-effective, compact thermistors, PT100 RTDs, type J/K/T and stand-alone data logging system thermocouple temperature sensors, that can be used with a wide variety internal temperature, pulse counter, frequency meter and up to 20 userof applications. This 16-bit, highdefined sensors (used for scaling resolution, 8-channel data logger analog voltage or current inputs in has graphic displays and analysis engineering units). functions for measuring voltage, current and temperature in real time. The OM-DAQPRO-5300-UNIV can With its high-resolution and fast record data from up to eight 2-wire or analog-to-digital converter (ADC), the four 3-wire PT100 RTD inputs (two OM-DAQPRO-5300-UNIV meets the input channels are required for each majority of data logging requirements 3-wire PT100 RTD input connected). in most industrial applications. Its Frequency/pulse counter is only unique ability to display measured available for input 1. values and analyze them in real time The data logger provides a on a graphical interface minimizes the need to download collected data simple and straightforward tool for defining up to 20 custom sensors. to a computer for further analysis. Almost any 0 to 10 V and 4 to 20 mA sensor or transducer can be displayed and scaled in meaningful engineering units, e.g., psi or gpm. The sensor definitions are stored in the data logger’s memory and are added to the sensors list. The sensor’s readings are displayed in the user-defined units both on the OM-DAQPRO-5300-UNIV’s LCD screen and the Windows software. The inputs use pluggable screw terminal blocks for easy connection. An internal clock and calendar keep track of the date and time of every sample measured. SM Extended Warranty Program OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARESM covers parts, labor and equivalent loaners.
Open the catalog to page 1The OM-DAQPRO-5300-UNIV data logger includes Windows software on CD ROM, Universal 100 to 240 Vac adaptor, USB cable, NIST calibration certificate, operator’s manual and carrying case. The OM-DAQPRO-5300-UNIV can automatically activate an external alarm device, e.g., energize an audible alarm or turn on a warning light, when an input channel is outside a specified range (Input/ Output 8 serves as either an input or an alarm output). The external alarm device (audible or visual alarm) is connected to the screw terminals of Input/Output 8. The alarm output is an open collector output, which...
Open the catalog to page 2Windows software displays data in graphical or tabular format Windows software high/low alarm setup Internal Temperature Range: -25 to 70°C (-13 to 158°F) Resolution: 0.1°C (1µV) Accuracy: ±0.5°C Pulse Counter (Input 1 Only) Optocoupler Input Range: 0 to 65,000 counts Resolution: 1 count Input Signal: 0 to 5V Input Impedance: 470 Ω Bandwidth: 0 to 25 Hz Frequency Meter (Input 1 Only) Optocoupler Input Range: 20 to 4000 Hz Time Resolution: 6.5 µs Input Signal: 0 to 5V Input Impedance: 470 Ω General A/D Specifications Noise: 30 µV RMS Internal Linearity Error: ±0.08% of FSR Offset Error: 0.1%...
Open the catalog to page 3The OM-DAQPRO-5300-UNIV data logger includes Windows software on CD ROM, universal 100 to 240 Vac adaptor, USB cable, NIST calibration certificate, operator’s manual and carrying case. Analysis Software Operating System: Windows XP/ VISTA/7 Features: • ast data download F • ata displayed in numeric D or graphical form • raphical analysis tools such G as Zoom and Cursors • torage of selected data S on disk files • ard-copy printing of the H collected data • irect data export to Excel D • nline retrieval and display O of data in real time • ncorporates data processing I functions • ata logger...
Open the catalog to page 4All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
Coriolis Mass Flow Meter
4 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer-PTC_14
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer_PTC 16
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
iDRN/iDRX Series
9 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger
5 Pages