Catalog excerpts
Non-Contact Voltage Detector with Adjustable Sensitivity HHM-NCV40 U rovides a Safe P (Non-Contact) Way to Check Whether an Electric Line or Cable or AC Outlet is “Hot” (Energized) U eeper Sounds and B Red LED Flashes When Voltage is Detected U Wide Voltage Range U djustable Sensitivity A Takes the Guesswork Out of Identifying the “Hot” Wire of a Bundle U afe for CAT IV S 1000V Use U ETL Approved U uilt-In Bright White B LED Flashlight U Pocket Clip The HHM-NVC40 provides a safe non-contact way to check whether an electric line or cable or AC outlet is “hot” (energized). It does so by sensing from a short distance the electromagnetic field created by AC voltage. Even unloaded AC circuits generate electromagnetic fields. Although these fields are extremely weak, their constantly changing nature means that they generate some current. A sensitive non-contact voltage detector can sense this current via induction, in much the same way that a sensitive radio receiver can sense weak radio waves. Noncontact voltage (NCV) detectors, including the HHM-NCV40, cannot detect DC voltages (such as those found in automotive electrical systems) or AC voltage through a wall or metal conduit. HHM-NCV40 shown smaller than actual size. Unlike the typical NCV detector, the HHM-NCV40 has adjustable sensitivity—a feature that makes it possible to determine which wire in a bundle is the “hot” wire. This application calls for turning down the sensitivity in stages after the HHM-NCV40 senses voltage. As you reduce sensitivity, at some stage only the energized wire will produce a field strong enough to activate the audible and visual alarms from a short distance. In this way, the HHM-NCV40’s adjustable sensitivity takes the guesswork out of identifying the “hot” wire of a bundle. The HHM-NCV40 also has a wider detection range (5 to 1000 Vac) than the typical NCV unit. The ability to detect the presence of 12 Vac in noncontact fashion is particularly useful during troubleshooting of hardwired process plant and industrial automation systems and equipment such as gas and water valves, fans, lights, relays, inverters, solenoids and horns. Hardwired commercial and residential building doorbells/ buzzers and thermostats are also commonly powered by 12 Vac. The ability of the HHM-NCV40 to detect 480V using its lowest sensitivity setting makes troubleshooting and installing generators and fluorescent lighting ballasts easier, faster and safer. Detection Range: 5 to 1000 Vac at 50 to 400 Hz Detection Distance: 64 mm (2.5") max Power Source: 2 “AAA” batteries (included) Operating Temperature: 0 to 40°C (32 to 104°F) @ <85% RH Dimensions: 154 L x 32 W x 28 mm D (6.1 x 1.3 x 1.1") Weight (with Batteries): 55 g (1.8 oz) HHM-NCV40 Non-contact voltage detector with adjustable sensitivity Comes complete with 2 “AAA” batteries and operator’s manual. Ordering Example: HHM-NCV40, non-contact voltage detecto
Open the catalog to page 1All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
Coriolis Mass Flow Meter
4 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer-PTC_14
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer_PTC 16
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
iDRN/iDRX Series
9 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
OM-DAQPRO-5300
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger
5 Pages