1. Catalogs
  2. OMEGA
  3. Non-Contact Voltage Detector with Adjustable Sensitivity

Non-Contact Voltage Detector with Adjustable Sensitivity
1 /1Page

Non-Contact Voltage Detector with Adjustable Sensitivity

Non-Contact Voltage Detector with Adjustable Sensitivity
1 /1Page

Catalog excerpts

Non-Contact Voltage Detector with Adjustable Sensitivity-1

Non-Contact Voltage Detector with Adjustable Sensitivity HHM-NCV40 U rovides a Safe P (Non-Contact) Way to Check Whether an Electric Line or Cable or AC Outlet is “Hot” (Energized) U eeper Sounds and B Red LED Flashes When Voltage is Detected U Wide Voltage Range U djustable Sensitivity A Takes the Guesswork Out of Identifying the “Hot” Wire of a Bundle U afe for CAT IV S 1000V Use U ETL Approved U uilt-In Bright White B LED Flashlight U Pocket Clip The HHM-NVC40 provides a safe non-contact way to check whether an electric line or cable or AC outlet is “hot” (energized). It does so by sensing from a short distance the electromagnetic field created by AC voltage. Even unloaded AC circuits generate electromagnetic fields. Although these fields are extremely weak, their constantly changing nature means that they generate some current. A sensitive non-contact voltage detector can sense this current via induction, in much the same way that a sensitive radio receiver can sense weak radio waves. Noncontact voltage (NCV) detectors, including the HHM-NCV40, cannot detect DC voltages (such as those found in automotive electrical systems) or AC voltage through a wall or metal conduit. HHM-NCV40 shown smaller than actual size. Unlike the typical NCV detector, the HHM-NCV40 has adjustable sensitivity—a feature that makes it possible to determine which wire in a bundle is the “hot” wire. This application calls for turning down the sensitivity in stages after the HHM-NCV40 senses voltage. As you reduce sensitivity, at some stage only the energized wire will produce a field strong enough to activate the audible and visual alarms from a short distance. In this way, the HHM-NCV40’s adjustable sensitivity takes the guesswork out of identifying the “hot” wire of a bundle. The HHM-NCV40 also has a wider detection range (5 to 1000 Vac) than the typical NCV unit. The ability to detect the presence of 12 Vac in noncontact fashion is particularly useful during troubleshooting of hardwired process plant and industrial automation systems and equipment such as gas and water valves, fans, lights, relays, inverters, solenoids and horns. Hardwired commercial and residential building doorbells/ buzzers and thermostats are also commonly powered by 12 Vac. The ability of the HHM-NCV40 to detect 480V using its lowest sensitivity setting makes troubleshooting and installing generators and fluorescent lighting ballasts easier, faster and safer. Detection Range: 5 to 1000 Vac at 50 to 400 Hz Detection Distance: 64 mm (2.5") max Power Source: 2 “AAA” batteries (included) Operating Temperature: 0 to 40°C (32 to 104°F) @ <85% RH Dimensions: 154 L x 32 W x 28 mm D (6.1 x 1.3 x 1.1") Weight (with Batteries): 55 g (1.8 oz) HHM-NCV40 Non-contact voltage detector with adjustable sensitivity Comes complete with 2 “AAA” batteries and operator’s manual. Ordering Example: HHM-NCV40, non-contact voltage detecto

 Open the catalog to page 1

All OMEGA catalogs and technical brochures

  1. WTS Series

    4  Pages

  2. DPG280

    2  Pages

  3. OMPBD7 series

    6  Pages

  4. Model H

    1  Page

  5. HHAQ-104

    1  Page

  6. DOTX441

    1  Page

  7. TXDIN1600s

    2  Pages

  8. M12

    1  Page

  9. AHPF Series

    1  Page

  10. RFH Series

    2  Pages

  11. HHM10

    6  Pages

  12. RDXL8

    2  Pages

  13. FD-400 Series

    4  Pages

  14. OS-MINIHUB

    4  Pages

  15. RHCM-40-PL-P

    2  Pages

  16. CSMSTRLE

    3  Pages

  17. AU-PTV Series

    3  Pages

  18. ADAM-5000

    7  Pages

  19. KE Series

    1  Page

  20. SRM Series

    3  Pages

  21. SRL Series

    3  Pages

  22. PHH-SD1

    2  Pages

  23. PHH222

    1  Page

  24. PHH224

    1  Page

  25. PHH720

    1  Page

  26. PHH830

    2  Pages

  27. PHH-126

    1  Page

  28. PHH-127

    1  Page

  29. PHH-128

    1  Page

  30. PHH-37

    1  Page

  31. PHH-715

    2  Pages

  32. PHH103B

    1  Page

  33. BB-5

    2  Pages

  34. BB-2A

    2  Pages

  35. CA 150

    5  Pages

  36. CL 110

    2  Pages

  37. CL 1600

    2  Pages

  38. CL 1201

    2  Pages

  39. CL 355A

    2  Pages

  40. FL 500

    2  Pages

  41. FL 500WW

    2  Pages

  42. FL-X

    2  Pages

  43. FPR 100

    3  Pages

  44. FSW500

    2  Pages

  45. FSW 420- 430

    2  Pages

  46. CDTX90

    6  Pages

  47. FSW 6000-7000

    3  Pages

  48. DRP 8500

    3  Pages

  49. DP 3300

    2  Pages

  50. DP119

    1  Page

  51. HE-X Series

    3  Pages

  52. HE359 Series

    3  Pages

  53. RD4

    2  Pages

  54. DPi

    3  Pages

  55. HH311

    2  Pages

  56. MP1

    1  Page

  57. HFS

    2  Pages

  58. CO

    2  Pages

  59. WT

    2  Pages

Archived catalogs

  1. 6M Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.