Low Flow Turbine Meters For Liquid and Gas Applications FLR1000 Series Optional U PPS or Brass Construction U 1% Accuracy for Liquids U Up to 0.2% Repeatability U 0 to 5V Analog Output U Available With or Without Display FLR1001, shown actual size. FLR1000 Series flow sensors can measure extremely low flow rates from 20 mL/min to 5 L/min. These sensors are suitable for a wide variety of industrial, commercial, and laboratory flow applications. FLR1000 Series flow sensors operate on 12 Vdc power and are designed for incorporation into data acquisition systems that supply 12.5 Vdc to sensors and receive 0 to 5 Vdc linear signals in return. Because of their cost effectiveness, FLR1000 Series units may replace conventional glass tube and ball flowmeters in applications in which an electrical signal proportional to flow rate is desired. The FLR1000 Series uses a Pelton-type turbine wheel to determine the flow rate of the gas. The rotation rate of the turbine wheel is linear over a wide dynamic range. The electro-optical system consists of a diode emitting energy in the infrared spectrum. Light energy is alternatively reflected and absorbed from “spokes” deposited on the small turbine wheel. This reflected light energy is detected by a photodiode. Thus, as the turbine wheel rotates in response to gas flow rate, electrical pulses are generated. Processing circuitry provides a DC voltage output proportional to the flow rate. For example, output signal is 1.0 Vdc at 20% of rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc at 80% of rated flow, and 5.0 Vdc at 100% of rated flow. Sensors can handle 20% above their rated flow without being damaged. For liquid flow metering with integrated rate display, the FLR1000ST-D Series has been setting the pace. Their advanced Pelton-turbine design provides high turndown ratios, fast response, and repeatable accuracy. A 0 to 5 Vdc analog output is standard. Featuring a 31⁄2-digit display of flow rate in engineering units, these flowmeters are perfect for any laboratory or test facility. For higher-pressure applications or where metal may be required, the FLR1000ST Series is the solution, see page F-89 for complete details. FLR1009ST-D, shown actual size. Specifications (FLR1000 Series) Accuracy: ±1% FS (liquids), ±3% (gases) Display: 31⁄2 -digit LCD, 22 mm (7⁄8") H Output Signal: 0 to 5 Vdc, adjustable ±20% (typical) Power Requirement: 11.5 to 15 Vdc regulated, 30 mA (typical) Standard Sensor Material: 40% glass filled polyphenelene sulfide, glass window, stainless steel bearing support; sapphire shaft and bearing; FKM rubber O-rings stan
Open the catalog to page 1Pressure Rating: 40 psi at 20°C (68°F) for gas, 100 psi for liquid, 500 psi for brass units using liquid services Temperature Rating: 0 to 50°C (32 to 122°F) Temperature Sensitivity: ±0.2%/°C Linearity: ±3% FS Repeatability: ±0.5% FS from 50 to 100% of rated maximum flow for gas; ±0.2% FS for liquid Cable Assembly: 0.9 m (3’) cable length Dimensions: Display: 76 x 44 x 89 mm (3 x 1.75 x 3.5") Non-Display: 60 x 42 x 37 mm (2.35 x 1.65 x 1.25") Pressure Sensitivity: ±0.07%/mm Hg (using air at 1 to 3 atm) Mounting: Holes for #4 screw provided Options Order Suffix Description -BR Brass body -P Pulse...
Open the catalog to page 24 Pages
2 Pages
6 Pages
1 Page
2 Pages
3 Pages
1 Page
5 Pages
2 Pages
1 Page
4 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
30 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
6 Pages
32 Pages
9 Pages
2 Pages
5 Pages
2 Pages
4 Pages
4 Pages
1 Page
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
7 Pages
1 Page
3 Pages
3 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
5 Pages
2 Pages
2 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
6 Pages
3 Pages
3 Pages
2 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
3 Pages
5 Pages
2 Pages
3 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages