Catalog excerpts
Thermocouple Signal Conditioners iDRX-TC Starts at OMEGA manufactures thousands of thermocouple probes. Please see page 2 or visit omega.co.uk The iDRN-TC and iDRX-TC signal conditioners provide highly accurate, stable, isolated measurement of thermocouple sensors. Thermocouple types are selected and the outputs are scaled with the free configuration software, or can be done at the factory for no additional charge. The T/C Signal Conditioners can accept 9 different thermocouple types: J, K, T, E, R, S, B, N, and J DIN. 2 Models (Analogue or Digital Outputs) iDRN-TC provides an analogue output that is proportional to the input signal. The iDRX-TC uses a digital RS-485 communication link. Analogue Output Model The output of iDRN-TC can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the free Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (iDRN Analogue Output Model) Please Specify: Thermocouple Type Temperature High & Low Output Value High & Low Example: Type J, 0°C = 4 mA, 100°C = 20 mA Digital Output Model The iDRX-TC is a digital signal conditioner which communicates over an RS-485 communication link using either a simple, straightforward ASCII® Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. PATENTED Covered by U.S. and International patents and pending applications. simple Serial to Ethernet “bridge” or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet. Specifications Accuracy at 25°C: ±1°C Resolution: 0.1˚C Power Consumption: 2 W (84 mA @ 24 Vdc) Input Types: J, K, T, E, R, S, B, N, J DIN Input Ranges: See range chart iDRX Output: 2-wire (half duplex) RS-485 (OMEGA® serial protocol and MODBUS serial protocol) iDRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10 V compliance Thermocouple Default settings iDRN: Input Type K, Range 0 to 1000°F; Output 4 to 20 mA (custom settings available at no charge) Input Type MOST POPULAR MODEL HIGHLIGHTED! To Order (Specify Model Number) Model No. Digital signal conditioner with RS-485 output for Thermocouple sensors Signal conditioner with analogue output for thermocouple sensors DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units) Ethernet Connection The Optional EIS-2B iServer module can connect up to thirty-two iDRX RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iServer can also be used as a Factory setup and scaling Comes with complete operator’s manual. Ordering Example: iDRN-TC, signal conditioner, and DB9-RJ12, connector adaptor, £218 + 20 = £238. ߜ T/C Types J, K, T, E, R, S, B, N, J DIN ߜ 0.1°C Resolution ߜ ±1°C Accuracy ߜ 1800 Vdc Isolation ߜ 250 V/1 Min. Input Overvoltage Protection ߜ Free Setup and Configuration Software ߜ Factory Setup and Configuration Available at No Charge (for
Open the catalog to page 1RTD Signal Conditioners NEWPORT ߜ 100Ω Pt, 500Ω Pt, 1000Ω Pt ߜ 0.1°C Resolution ߜ ±0.5°C Accuracy ߜ 1800 Vdc Isolation ߜ Free Setup and Configuration Software ߜ Factory Setup and Configuration Available at No Charge (for iDRN Analogue Output models) The iDRN-RTD and iDRX-RTD signal conditioners provide highly accurate, stable, isolated measurement of RTD temperature sensors. Both models can accept 2, 3, or 4 wire 100Ω PT, 500Ω PT and 1000Ω PT RTDs. 2 Models (Analogue or Digital Outputs) The iDRN-RTD provides a fully scalable analogue output that is proportional to the input signal. The...
Open the catalog to page 2Strain Gauge/Bridge TransducerSignal Conditioners NEWPORT ߜ Unipolar/Bipolar 30 mV to 100 mV ߜ 13-Bit Resolution ߜ 10 Vdc Excitation ߜ 0.2% FS Accuracy ߜ 1800 Vdc Isolation ߜ 250 Vac/1 Min. Input Overvoltage Protection ߜ Free Setup and Configuration Software ߜ Factory Setup and Configuration Available at No Charge (for iDRN Analogue Output models) The iDRN-ST and iDRX-ST signal conditioners provide highly accurate, stable, isolated measurement for strain gauge transducers such as load cells, torque transducers, non-amplified pressure transducers, and other bridge based transducers. Both...
Open the catalog to page 3Process Inputs Signal Conditioners iDRX-PR ߜ Unipolar/Bipolar 400 mV to 10 Vdc, 0 to 20 mA dc ߜ 11 to 14-Bit Resolution ߜ ±0.1% FS Accuracy ߜ 14 Vdc Excitation ߜ 1800 Vdc Isolation ߜ 250 Vac/1 Min. Input Overvoltage Protection (Voltage Input Only) ߜ Free Setup and Configuration Software PATENTED ߜ Factory Setup and Covered by U.S. and Configuration Available International patents at No Charge (for iDRN and pending applications. Analogue Output models) The iDRN-PR and iDRX-PR signal conditioners provide highly accurate, stable, isolated measurement of process signals. Both models can accept...
Open the catalog to page 4Frequency/Pulse Digital Signal Conditioners iDRX-FP PATENTED Covered by U.S. and International patents and pending applications. ߜ Software Selectable Input Type ߜ 0 to 50 KHz Frequency Input 2 Million Pulse Capacity ߜ Proximity, Switch, Magnetic, Pickup, NAMUR, Contact Closure and Open Collector Input Types ߜ RS-485 Output ߜ 1800 Vdc Isolation ߜ Free Setup and Configuration Software ߜ Factory Setup and Configuration Available at No Charge (for iDRN Analogue Output models) The iDRN-FP and iDRX-FP signal conditioners provide accurate, stable, isolated measurement of frequency and pulse...
Open the catalog to page 5AC Voltage/Current Signal Conditioners NEWPORT ߜ Software Selectable Input Ranges iDRX-ACV: 0 to 400 mV to 0 to 400 Vac iDRX-ACC: 0 to 10 mA to 0 to 5 A ac ߜ 14-Bit Resolution (max) ߜ 0.2% FS Accuracy ߜ 1800 Vdc Isolation ߜ Free Setup and Configuration Software ߜ Factory Setup and Configuration Available at No Charge (for iDRN Analogue Output models) The iDRN and iDRX Series signal conditioners provide highly accurate, stable and isolated measurement of AC voltage and current signals across extremely wide ranges: AC Current ranges from 0 to 10 mA through 0 to 5 A ac; AC Voltage ranges from...
Open the catalog to page 6All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
Coriolis Mass Flow Meter
4 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
OM-DAQPRO-5300
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger