1. Catalogs
  2. OMEGA
  3. Economical DIN Rail Signal Conditioners CCT Series

Economical DIN Rail Signal Conditioners CCT Series

Economical DIN Rail Signal Conditioners CCT Series

Economical DIN Rail Signal Conditioners CCT Series

Product catalog summary
Overview: The CCT Series DIN Rail Signal Conditioners are versatile devices designed to process various input signals such as voltage, current, frequency, resistance, potentiometer, thermocouple, RTD, and strain gauge inputs. They provide standard process outputs of 0/4 to 20 mA or 0 to 10 Vdc and are compatible with 35 mm DIN rails.
Specifications: The CCT series features a modular design with plug-in modules for power supply, input, and output signals. Power options include 110 Vac, 220 Vac, and 24 Vdc. The units offer 2 kVeff isolation between input and output, with outputs available in current and voltage forms. The accuracy is ≤0.2% or ≤0.3%, with a response time of ≤250 ms. Operating temperature ranges from -10 to 60°C.
Input Modules: The series includes various models for different input types:
  • Voltage and Current Inputs: Models like CCT-01 and CCT-08 handle dc and ac voltage inputs respectively, with ranges from 100 mV to 650 V.
  • Thermocouple Inputs: Models like CCT-22 to CCT-27 support J, K, T, E, R, and S type thermocouples with linearized outputs.
  • RTD Inputs: The CCT-20 model supports 100Ω Pt RTD signals with 0.2% accuracy.
  • Potentiometer and Resistance Inputs: Models like CCT-90 and CCT-95 handle potentiometer and resistance inputs respectively.
  • Frequency Inputs: The CCT-05 model supports frequency ranges from 40 Hz to 40 kHz.
  • Strain Gauge Inputs: The CCT-80 model is designed for strain gauge sensors with 20 mV output and 10 V excitation.
Additional Features: The series includes integrator modules for converting voltage or current to frequency, and loop-powered galvanic isolators for applications requiring input-output isolation. The FAR series power supplies provide additional support for bridge circuits and other transducers.
Ordering Information: Each model is available with different input ranges and power supply options. The standard power supply is 110 Vac, with options for 220 Vac or 24 Vdc at an additional cost for the latter.
Product Overview: The document provides details on two main products: the CCT-55 Signal Integrators and the CCT-100 Galvanic Isolator. These products are designed for converting analog signals to frequency outputs and providing galvanic isolation, respectively.
CCT-55 Signal Integrators:
  • Functionality: Converts analog voltage/current to frequency output, with the ability to source or sink output.
  • Output Ranges: From 1 pulse/hour to 10,000 pulses/second full scale.
  • Input Ranges: Voltage inputs range from 0-0.1 Vdc to 0-650 Vdc, and current inputs range from 0-5 mA to 0-50 mA.
  • Output Specifications: 15 Vdc @ 5 mA source or 100 mA sink with 24 Vdc external supply.
  • Adjustments: Output ranges are field settable through jumper selection and potentiometer adjustment.
CCT-100 Galvanic Isolator:
  • Functionality: Provides 2 kV input to output isolation, with a 1:1 input/output ratio.
  • Input Specifications: 0 to 50 mA dc input current, with a maximum input voltage of 18 Vdc.
  • Output Specifications: 0 to 50 mA dc output current, with a ripple of 0.5% at 3 kHz.
  • Performance: Response time of 50 ms, accuracy of 0.1% at 25°C, and a temperature coefficient of 0.01% per 10°C from 10 to 60°C.
  • Physical Dimensions: 75 H x 22.5 W x 98.5 mm D, weighing 100 g.
Ordering Information:
  • For CCT-55 models, specify voltage input and add "-220VAC" or "-24VDC" for different power options. The 220 Vac option has no additional charge, while the 24 Vdc option adds $50 to the price.
  • For CCT-100, the price is $130, and it is loop powered.
Additional Products: The document also lists a wide range of other products available, including calibrators, connectors, temperature measurement instruments, pressure and strain measurement devices, heaters, flowmeters, and data acquisition systems.
See more

Catalog excerpts

Economical DIN Rail Signal Conditioners CCT Series-1

Economical DIN Rail CARE Signal Conditioners CCT Series OMEGA Extended Warranty Program Shown larger than actual size. ߜ Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules ߜ Integrator Modules Convert Voltage or Current to Frequency ߜ Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output ߜ Compatible with Standard 35 mm DIN Rail The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module. Internal Design The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. Available power supplies include 110 Vac, 220 Vac, and 24 Vdc. Isolation The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff. Outputs Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc. Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.

 Open the catalog to page 1
Economical DIN Rail Signal Conditioners CCT Series-2

Integrators The CCT integrator signal conditioners accept either voltage or current signals, and provide a frequency pulse output. This pulse output can be used as input signals for PLCs or other industrial controls. Additional Features Additional models in the CCT series include the FAR power supplies, that can be used with the CCT-80 strain gage transmitter, to provide wheatstone bridge excitation. The loop-powered galvanic isolator model CCT-100 can be used in any application where input to output isolation is required. The CCT-100 provides up to 2 kVeff isolation between the input and output...

 Open the catalog to page 2
Economical DIN Rail Signal Conditioners CCT Series-3

Economical DIN Rail Signal Conditioners CCT Series ac/dc Voltage and Current Input Models ߜ ac/dc Voltage Input Ranges from 100 mV to 650 V ߜ ac/dc Current Input Models with 0 to 50 mA or 0 to 5 A ߜ Overvoltage Protection for Voltage Inputs ߜ High Impedance Voltage Inputs ߜ Low Impedance Current Inputs The CCT series of ac and dc input signal conditioners accept analog signals and provide conditioned, isolated analog outputs of 0 to 10 V or 0/4 to 20 mA. The CCT-01 accepts dc voltages, the CCT-08 accepts ac voltages, while the CCT-04 and CCT-32 accept ac and dc current signals, respectively....

 Open the catalog to page 3
Economical DIN Rail Signal Conditioners CCT Series-4

dc Current Input Models Currant generator (active transducer Passive transducer INPUT SIGNAL INPUT SIGNAL To Order (Specify Model Number) Model Number† Price Input Range † 110 Vac powered units supplied standard. To order 220 Vac or 24 Vdc powered models add “-220VAC” or “-24VDC” to the model number. No additional charge for 220 Vac, add $50 to price for 24 Vdc. Ordering Example: CCT32-0/5MA dc current input signal conditioner with 0 to 5 mA range, $170. Impedance Overload Shown smaller than actual size Voltage Excitation for Current Loop: 24 V dc @ 25 mA, supplied by converter Thermocouple Input...

 Open the catalog to page 4
Economical DIN Rail Signal Conditioners CCT Series-5

Economical DIN Rail Signal Conditioners CCT Series CCT-20 RTD Input Models ߜ 100Ω Pt RTD Element, 0.00385 Curve ߜ 2 or 3 Wire Configuration ߜ 0.2% Accuracy ߜ Downscale Break Protection ߜ 1 mA Max Excitation Current outputs of 0 to 10 V or 0/4 to 20 mA. Units are 110 Vac powered (220 Vac or 24 Vdc power also available). Modules are mountable on standard 35 mm DIN rail, and are isolated to 2 kVeff. (3 Wire) The CCT-20 signal conditioners accept 100Ω Pt RTD signals, and provide conditioned, isolated INPUT SIGNAL INPUT SIGNAL To Order (Specify Model Number) Model Number† Price Shown smaller than...

 Open the catalog to page 5
Economical DIN Rail Signal Conditioners CCT Series-6

CCT-05 Frequency Input Models ߜ NPN, PNP, NAMUR, Open Collector, Contact, or TTL Inputs or AC Voltage (100 mV to 400 Vac) ߜ Signal Input Range from 40 Hz to 40 kHz ߜ Excitation for NPN, PNP and NAMUR Inputs The CCT-05 signal conditioners accepts inputs from a variety of frequency transducers, including NPN, PNP, NAMUR, open collector, contact or TTL pulse or AC voltage (100 mV to 400 Vac). Modules are supplied scalable for a minimum and maximum frequency range. The actual range is set by the user via multiturn trimmers, a frequency generator is also required. All units are 110 Vac powered (220...

 Open the catalog to page 6
Economical DIN Rail Signal Conditioners CCT Series-7

Economical DIN Rail Signal Conditioners CCT Series Strain Gage/Load Cell Input Models ߜ For Strain Gage Sensors with 20 mV Output and 10 V Excitation ߜ 4 and 6-Wire Bridge Sensors ߜ 350 Ω Sensor Impedance ߜ Companion FAR-1 Power Supply Module Provides Stabilized 10 Vdc Excitation for 4 Modules ߜ FAR Series Power Supplies Provide Bridge Excitation FAR-1 10 V, 250 mA power supply with excitation sense capability, $110. Shown smaller than actual size. The CCT-80 strain gauge/load cell signal conditioners accept input from 350Ω bridge circuits and provide isolated 0 to 10 V or 0/4 to 20 mA output....

 Open the catalog to page 7
Economical DIN Rail Signal Conditioners CCT Series-8

ߜ Convert Analog Voltage/Current to Frequency Output ߜ Source or Sink Output ߜ Output Ranges From 1 pulse/hour to 10,000 pulses/sec Full Scale The CCT-55 signal integrators provide conditioned, isolated frequency outputs proportional to the analog input signal. The CCT-55-V accepts voltages from 0-100 mV to 0-650 V, while the CCT-55-I accepts from 0 to 5 mA to 0 to 50 mA input. Output ranges are field setable through jumper selection and multiturn trimmers. A calibrator and frequency meter is required for adjustment. Specifications dc Voltage Input Ranges: 0-0.1 Vdc, 0-1 Vdc, 0-10 Vdc, 0-100...

 Open the catalog to page 8

All OMEGA catalogs and technical brochures

  1. WTS Series

    4  Pages

  2. DPG280

    2  Pages

  3. OMPBD7 series

    6  Pages

  4. Model H

    1  Page

  5. HHAQ-104

    1  Page

  6. DOTX441

    1  Page

  7. TXDIN1600s

    2  Pages

  8. M12

    1  Page

  9. AHPF Series

    1  Page

  10. RFH Series

    2  Pages

  11. HHM10

    6  Pages

  12. RDXL8

    2  Pages

  13. FD-400 Series

    4  Pages

  14. OS-MINIHUB

    4  Pages

  15. RHCM-40-PL-P

    2  Pages

  16. CSMSTRLE

    3  Pages

  17. AU-PTV Series

    3  Pages

  18. ADAM-5000

    7  Pages

  19. KE Series

    1  Page

  20. SRM Series

    3  Pages

  21. SRL Series

    3  Pages

  22. PHH-SD1

    2  Pages

  23. PHH222

    1  Page

  24. PHH224

    1  Page

  25. PHH720

    1  Page

  26. PHH830

    2  Pages

  27. PHH-126

    1  Page

  28. PHH-127

    1  Page

  29. PHH-128

    1  Page

  30. PHH-37

    1  Page

  31. PHH-715

    2  Pages

  32. PHH103B

    1  Page

  33. BB-5

    2  Pages

  34. BB-2A

    2  Pages

  35. CA 150

    5  Pages

  36. CL 110

    2  Pages

  37. CL 1600

    2  Pages

  38. CL 1201

    2  Pages

  39. CL 355A

    2  Pages

  40. FL 500

    2  Pages

  41. FL 500WW

    2  Pages

  42. FL-X

    2  Pages

  43. FPR 100

    3  Pages

  44. FSW500

    2  Pages

  45. FSW 420- 430

    2  Pages

  46. CDTX90

    6  Pages

  47. FSW 6000-7000

    3  Pages

  48. DRP 8500

    3  Pages

  49. DP 3300

    2  Pages

  50. DP119

    1  Page

  51. HE-X Series

    3  Pages

  52. HE359 Series

    3  Pages

  53. RD4

    2  Pages

  54. DPi

    3  Pages

  55. HH311

    2  Pages

  56. MP1

    1  Page

  57. HFS

    2  Pages

  58. CO

    2  Pages

  59. WT

    2  Pages

Archived catalogs

  1. 6M Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.