Economical DIN Rail CARE Signal Conditioners CCT Series OMEGA Extended Warranty Program Shown larger than actual size. ߜ Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules ߜ Integrator Modules Convert Voltage or Current to Frequency ߜ Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output ߜ Compatible with Standard 35 mm DIN Rail The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module. Internal Design The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. Available power supplies include 110 Vac, 220 Vac, and 24 Vdc. Isolation The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff. Outputs Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc. Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.

Open the catalog to page 1
Economical DIN Rail Signal Conditioners CCT Series - 2

Integrators The CCT integrator signal conditioners accept either voltage or current signals, and provide a frequency pulse output. This pulse output can be used as input signals for PLCs or other industrial controls. Additional Features Additional models in the CCT series include the FAR power supplies, that can be used with the CCT-80 strain gage transmitter, to provide wheatstone bridge excitation. The loop-powered galvanic isolator model CCT-100 can be used in any application where input to output isolation is required. The CCT-100 provides up to 2 kVeff isolation between the input and...

Open the catalog to page 2
Economical DIN Rail Signal Conditioners CCT Series - 3

Economical DIN Rail Signal Conditioners CCT Series ac/dc Voltage and Current Input Models ߜ ac/dc Voltage Input Ranges from 100 mV to 650 V ߜ ac/dc Current Input Models with 0 to 50 mA or 0 to 5 A ߜ Overvoltage Protection for Voltage Inputs ߜ High Impedance Voltage Inputs ߜ Low Impedance Current Inputs The CCT series of ac and dc input signal conditioners accept analog signals and provide conditioned, isolated analog outputs of 0 to 10 V or 0/4 to 20 mA. The CCT-01 accepts dc voltages, the CCT-08 accepts ac voltages, while the CCT-04 and CCT-32 accept ac and dc current signals,...

Open the catalog to page 3
Economical DIN Rail Signal Conditioners CCT Series - 4

dc Current Input Models Currant generator (active transducer Passive transducer INPUT SIGNAL INPUT SIGNAL To Order (Specify Model Number) Model Number† Price Input Range † 110 Vac powered units supplied standard. To order 220 Vac or 24 Vdc powered models add “-220VAC” or “-24VDC” to the model number. No additional charge for 220 Vac, add $50 to price for 24 Vdc. Ordering Example: CCT32-0/5MA dc current input signal conditioner with 0 to 5 mA range, $170. Impedance Overload Shown smaller than actual size Voltage Excitation for Current Loop: 24 V dc @ 25 mA, supplied by converter Thermocouple...

Open the catalog to page 4
Economical DIN Rail Signal Conditioners CCT Series - 5

Economical DIN Rail Signal Conditioners CCT Series CCT-20 RTD Input Models ߜ 100Ω Pt RTD Element, 0.00385 Curve ߜ 2 or 3 Wire Configuration ߜ 0.2% Accuracy ߜ Downscale Break Protection ߜ 1 mA Max Excitation Current outputs of 0 to 10 V or 0/4 to 20 mA. Units are 110 Vac powered (220 Vac or 24 Vdc power also available). Modules are mountable on standard 35 mm DIN rail, and are isolated to 2 kVeff. (3 Wire) The CCT-20 signal conditioners accept 100Ω Pt RTD signals, and provide conditioned, isolated INPUT SIGNAL INPUT SIGNAL To Order (Specify Model Number) Model Number† Price Shown smaller...

Open the catalog to page 5
Economical DIN Rail Signal Conditioners CCT Series - 6

CCT-05 Frequency Input Models ߜ NPN, PNP, NAMUR, Open Collector, Contact, or TTL Inputs or AC Voltage (100 mV to 400 Vac) ߜ Signal Input Range from 40 Hz to 40 kHz ߜ Excitation for NPN, PNP and NAMUR Inputs The CCT-05 signal conditioners accepts inputs from a variety of frequency transducers, including NPN, PNP, NAMUR, open collector, contact or TTL pulse or AC voltage (100 mV to 400 Vac). Modules are supplied scalable for a minimum and maximum frequency range. The actual range is set by the user via multiturn trimmers, a frequency generator is also required. All units are 110 Vac powered...

Open the catalog to page 6
Economical DIN Rail Signal Conditioners CCT Series - 7

Economical DIN Rail Signal Conditioners CCT Series Strain Gage/Load Cell Input Models ߜ For Strain Gage Sensors with 20 mV Output and 10 V Excitation ߜ 4 and 6-Wire Bridge Sensors ߜ 350 Ω Sensor Impedance ߜ Companion FAR-1 Power Supply Module Provides Stabilized 10 Vdc Excitation for 4 Modules ߜ FAR Series Power Supplies Provide Bridge Excitation FAR-1 10 V, 250 mA power supply with excitation sense capability, $110. Shown smaller than actual size. The CCT-80 strain gauge/load cell signal conditioners accept input from 350Ω bridge circuits and provide isolated 0 to 10 V or 0/4 to 20 mA...

Open the catalog to page 7
Economical DIN Rail Signal Conditioners CCT Series - 8

ߜ Convert Analog Voltage/Current to Frequency Output ߜ Source or Sink Output ߜ Output Ranges From 1 pulse/hour to 10,000 pulses/sec Full Scale The CCT-55 signal integrators provide conditioned, isolated frequency outputs proportional to the analog input signal. The CCT-55-V accepts voltages from 0-100 mV to 0-650 V, while the CCT-55-I accepts from 0 to 5 mA to 0 to 50 mA input. Output ranges are field setable through jumper selection and multiturn trimmers. A calibrator and frequency meter is required for adjustment. Specifications dc Voltage Input Ranges: 0-0.1 Vdc, 0-1 Vdc, 0-10 Vdc,...

Open the catalog to page 8
Economical DIN Rail Signal Conditioners CCT Series - 9

Your One-Stop Source for Process Measurement and Control! UNITED STATES Deckenpfronn, Germany UNITED KINGDOM Manchester, England More than 100,000 Products Available! Calibrators, Connectors, General Test and Measurement Instruments, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders, Relative Humidity Measurement Instruments, PT100 Probes, PT100 Elements, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching...

Open the catalog to page 9

All OMEGA catalogs and technical brochures

  1. WTS Series

    4 Pages

  2. DPG280

    2 Pages

  3. Model H

    1 Pages

  4. HHAQ-104

    1 Pages

  5. DOTX441

    1 Pages

  6. TXDIN1600s

    2 Pages

  7. M12

    1 Pages

  8. AHPF Series

    1 Pages

  9. RFH Series

    2 Pages

  10. HHM10

    6 Pages

  11. RDXL8

    2 Pages

  12. OS-MINIHUB

    4 Pages

  13. RHCM-40-PL-P

    2 Pages

  14. CSMSTRLE

    3 Pages

  15. ADAM-5000

    7 Pages

  16. KE Series

    1 Pages

  17. SRM Series

    3 Pages

  18. SRL Series

    3 Pages

  19. PHH-SD1

    2 Pages

  20. PHH222

    1 Pages

  21. PHH224

    1 Pages

  22. PHH720

    1 Pages

  23. PHH830

    2 Pages

  24. PHH-126

    1 Pages

  25. PHH-127

    1 Pages

  26. PHH-128

    1 Pages

  27. PHH-37

    1 Pages

  28. PHH-715

    2 Pages

  29. PHH103B

    1 Pages

  30. BB-5

    2 Pages

  31. BB-2A

    2 Pages

  32. CA 150

    5 Pages

  33. CL 110

    2 Pages

  34. CL 1600

    2 Pages

  35. CL 1201

    2 Pages

  36. CL 355A

    2 Pages

  37. FL 500

    2 Pages

  38. FL 500WW

    2 Pages

  39. FL-X

    2 Pages

  40. FPR 100

    3 Pages

  41. FSW500

    2 Pages

  42. FSW 420- 430

    2 Pages

  43. CDTX90

    6 Pages

  44. DRP 8500

    3 Pages

  45. DP 3300

    2 Pages

  46. DP119

    1 Pages

  47. HE-X Series

    3 Pages

  48. HE359 Series

    3 Pages

  49. RD4

    2 Pages

  50. DPi

    3 Pages

  51. HH311

    2 Pages

  52. MP1

    1 Pages

  53. HFS

    2 Pages

  54. CO

    2 Pages

  55. WT

    2 Pages

Archived catalogs

  1. 6M Series

    2 Pages