Coriolis Mass Flow Meter Mass Flow, Density, Temperature and Volume Flow Meter FMC-5000 Series TM U 5 to 150 mm 1 (1⁄2 to 6") Sizes U ass Flow Rate, M Volume, Density and Temperature Measurements U ugged Meters with No R Moving Parts Results in Minimal Maintenance U ccuracy Over a Wide A Flow Range From a Single Meter Optimizes Plant Efficiency U o Flow Conditioning N or Straight Pipe Runs Required, Making Installation Simplified and Less Expensive The FMC-5000 Coriolis Mass Flow Meter is designed according to the Coriolis Force Principle. It is widely used for flow measurements and custody transfer in many industries such as petroleum, petrochemical, chemical, pharmaceutical, pulp and paper, food and dairy, and more. As an advanced flow and density measurement instrument, it is widely used in the measurement of liquids, gases and slurries, and garners a high reputation among customers around the globe. Coriolis meters are typically used in applications like batch control, blending, filling, dosing, custody transfer, process gas measurements, and more. The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. FMC-5000 shown smaller than actual size. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation. Fluid reactive force (outlet) Fluid reactive force (inlet) oscillating flow tube, response to
Open the catalog to page 1Flow Accuracy/Repeatability: FMC-5100: 0.1/0.05% (Liquid Only) FMC-5200: 0.2/0.1% (Liquid Only) FMC-5500: 0.5/0.25% Density Measuring: Range: 0.2 to 3.0 g/cm3 Error: ± 0.002 g/cm3 Repeatability: 0.001 g/cm3 Temperature Accuracy: ±1.0ºC Protection: NEMA 4X (IP65) Approvals: CE, RoHS (Pending) Communications: RS485 (RTU Modbus®), HART® (-HART option) Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale Current Output: 4 to 20 mA, 0.005% Full Scale Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W Pressure Loss Curves: Available in operator’s manual Flow Range: See charts below...
Open the catalog to page 2Remote Type Transmitter. Dimensions Size DN (ANSI)
Open the catalog to page 3Comes complete with operator’s manual. For meters with other than ANSI flanges, change the “A” at the end of the model number to “D” for DIN flanges, “J” for JIS flanges or “S” for sanitary flanges (liquid only), no additional charge. To replace the RS485 communications with HART communications add “-HART” to the model number, for an additional charge. For units with remote mounted display/transmitter add “-R” to the model number, for an additional charge. Ordering Example: FMC-5203LA-HART-R, remote mount meter, 11⁄2" ANSI flanges, 1000 to 24,0
Open the catalog to page 4All OMEGA catalogs and technical brochures
-
WTS Series
4 Pages
-
DPG280
2 Pages
-
OMPBD7 series
6 Pages
-
BEAKER HEATERS
1 Pages
-
OM-CP-SHOCK-SERIES
2 Pages
-
Isolated signal converter
3 Pages
-
FLOAT LEVEL TRANSMITTER
1 Pages
-
Smart Graphics Displays
5 Pages
-
Long Range Wireless Receiver
2 Pages
-
Ultrasonic Leak Detector
1 Pages
-
EZ-VIEW FLOWMETERS
1 Pages
-
Programmable Timer-PTC_14
1 Pages
-
Sanitary Dial Thermometers
2 Pages
-
Model H
1 Pages
-
Programmable Timer_PTC 16
1 Pages
-
Low Flow Turbine Meters
2 Pages
-
MICRO-FLOW METER
1 Pages
-
Connector/Transmitter
1 Pages
-
HHAQ-104
1 Pages
-
DuraBand® with Built-In Strap
30 Pages
-
DOTX441
1 Pages
-
DOCN600 Series
2 Pages
-
TXDIN1600s
2 Pages
-
M12
1 Pages
-
Benchtop Weight Scale
1 Pages
-
AHPF Series
1 Pages
-
LP-PS Series Power Supplies
1 Pages
-
RFH Series
2 Pages
-
HHM10
6 Pages
-
OMEGA RTD BROCHURE
32 Pages
-
iDRN/iDRX Series
9 Pages
-
RDXL8
2 Pages
-
iBTX and iBTHX Series
5 Pages
-
HHWT-12 Series
2 Pages
-
FD-400 Series
4 Pages
-
OM-DAQPRO-5300
4 Pages
-
M12-TC-SL Series
1 Pages
-
OS-MINI22-151-D-MA-MT
4 Pages
-
OS-MINIHUB
4 Pages
-
RHCM-40-PL-P
2 Pages
-
OS-MINIUSB-SN21
2 Pages
-
OSAT-151-C-LT-5
2 Pages
-
CSMSTRSX, CSMSTRGT
3 Pages
-
CSMSTRLE
3 Pages
-
AU-PTV Series
3 Pages
-
ADAM-5000
7 Pages
-
KE Series
1 Pages
-
SRM Series
3 Pages
-
SRL Series
3 Pages
-
SRF3 and SRF5 and SRF8
2 Pages
-
PHH-SD1
2 Pages
-
CDH-5020 Series
1 Pages
-
PHH222
1 Pages
-
PHH224
1 Pages
-
PHH720
1 Pages
-
PHH830
2 Pages
-
PHH-126
1 Pages
-
PHH-127
1 Pages
-
PHH-128
1 Pages
-
PHH-37
1 Pages
-
PHH-715
2 Pages
-
PHH103B
1 Pages
-
Strain Gauge Specifications
5 Pages
-
BB-5
2 Pages
-
BB-2A
2 Pages
-
CA 150
5 Pages
-
CL 110
2 Pages
-
CL 1600
2 Pages
-
CL 1201
2 Pages
-
CL 355A
2 Pages
-
FL 500
2 Pages
-
FL 500WW
2 Pages
-
FL-X
2 Pages
-
FPR 100
3 Pages
-
FL6100SS-7900SS
2 Pages
-
FSW500
2 Pages
-
FSW 420- 430
2 Pages
-
CL 1500 Series
3 Pages
-
CDTX90
6 Pages
-
FSW 6000-7000
3 Pages
-
DRP 8500
3 Pages
-
DP 3300
2 Pages
-
DP119
1 Pages
-
DURABLE BRASS WATER TURBINES
3 Pages
-
PLC/HMI CONTROLLERS
3 Pages
-
HE-X Series
3 Pages
-
HE359 Series
3 Pages
-
RD4
2 Pages
-
DPi
3 Pages
-
HH311
2 Pages
-
MP1
1 Pages
-
HFS
2 Pages
-
CO
2 Pages
-
WT
2 Pages
Archived catalogs
-
Band Heater MB-2 SERIES
2 Pages
-
Thermowells FTW
1 Pages
-
Round Terminal Blocks
2 Pages
-
thermocouple terminal block
2 Pages
-
6M Series
2 Pages
-
Fine Diameter Thermocouples
3 Pages
-
Sound Level Meter HHSL
2 Pages
-
Hot Wire Anemometer HHF42
2 Pages
-
OTF Strip Heater Series
2 Pages
-
Wireless bore scope HHB1800
2 Pages
-
Wireless Receivers UWTC-REC
3 Pages
-
Portable Data Logger
5 Pages