Product catalog summary
Introduction
Omega Fusibili S.p.A. has modernized its organization and expanded operations, forming a group of four companies with 85 employees and over 60 agents across Europe. The new headquarters in Assago features automated warehouses for enhanced logistical efficiency.
2012 Catalogue Overview
The 2012 catalogue introduces new products while maintaining its recognizable design. It includes divisions such as Electronic, Connection, Professional, and Power, with a new Air Moving division offering fans and accessories. Collaboration with Ventec enhances expertise in fan distribution.
Italian Headquarters
The headquarters includes 1,200 sqm of office space, 3,200 sqm of warehouse space, 2,800 pallet spaces, and 6,500 product locations, supported by automated logistics.
Product Categories
The catalogue covers various fuses, fuseholders, accessories, terminal blocks, switches, and thermal protections.
Fuse Specifications
Fuses are available in multiple sizes, including subminiature options. Common sizes are 5x20mm and 6.3x32mm. Selection is based on voltage rating, current load, and environmental conditions.
General Information
Fuses protect components and systems from overloads and short circuits. Correct fuse selection ensures safety and reliability in electronic circuits.
Color Code for Fuses
A detailed color code chart for fuses with current ratings from 32 mA to 6.3 A is provided.
Basic Fuse Technology
Miniature fuses protect against fire and shock risks from overcurrents and isolate subsystems from the main system during faults.
Selecting Overcurrent Protection
Consider voltage rating, full load currents, short circuit current, in-rush characteristics, equipment characteristics, ambient conditions, standards, board space, mounting type, reliability, and field service ease.
Voltage Ratings
The fuse's voltage rating must be greater than or equal to the circuit voltage, open quickly, extinguish the arc, and prevent re-striking.
Current Ratings
Fuses are marked with a nominal current rating. Factors affecting this include clip material, conductor size, and installation quality.
Breaking Capacity
A fuse must safely open the circuit under a short circuit without endangering surroundings.
Fuse Resistance
In most applications, the voltage drop across a fuse is negligible, but in critical applications, fuse resistance must be considered.
Glossary of Terms
Includes terms like I2t, arc time, operating time, fast fuses, overcurrents, overloads, ohmic load, RMS current, short circuit, delayed fuses, and nominal voltage.
Ambient Air Temperatures
Standardized tests are performed at 23°C and 25°C. Adjustments should be made for higher ambient temperatures.
Overview
Technical information on cylindrical fuses, focusing on specifications, operational parameters, and standards.
Key Specifications
  • Ampere Squared Seconds (I2t): Heat energy measure during a fault.
  • Arcing Time: Duration from fuse link melting to overcurrent interruption.
  • Clearing Time: Total time from overcurrent start to circuit opening.
  • Voltage Rating: Maximum open circuit voltage a fuse can handle.
Types of Fuses
  • Fast Acting Fuses: Quickly open on overloads and short circuits.
  • Time Delay Fuses: Allow temporary in-rush currents but open on sustained overloads.
  • Time Lag Fuses: Withstand short high current pulses.
Pulse Factor and Surge Withstand Capability
  • Select a fuse with a melting I2t value greater than or equal to the pulse I2t multiplied by a pulse factor (Fp).
  • Different construction types affect surge pulse withstand capability.
Standards for Miniature Fuses
  • IEC 60127 series outlines definitions and quality assessment guidelines.
  • UL 248 series provides general requirements for low-voltage fuses.
Technical Document Summary
Specifications
  • Dimensions: 5x20 mm and 6.3x32 mm fuses.
  • Voltage: 250 V and 500 V options.
  • Breaking Capacity: 35 A for glass body fuses, 1500 A for ceramic body fuses.
  • Body Material: Glass and Ceramic filled with Sand.
  • Trade Mark: OMEGA and OMEGA BUSS.
  • Standards: EN60127, VDE 0820, CEI 32.6.2, BS 4265, SEMKO 104, DIN 41661, UL/CSA 248-14.
Procedures
  • Time Delay Characteristics: Fuses available in fast (F) and time delay (T) characteristics.
  • Test Current: Various test currents specified.
Norms and Approvals
  • Fuses comply with multiple international standards and have approval codes like Bussmann S501, S505, GMA, GMD, and GMC.
Recommendations
  • Ensure correct rated current and breaking capacity for specific applications.
  • Consider body material and dimensions based on installation environment.
Key Data from Tables
  • Rated Current Range: From 50 mA to 25 A depending on the fuse type.
  • Voltage Drop and I2t Values: Provided for each rated current.
Critical Information
  • Fuses available in stock in quantities of 10/100 pcs and 1000 pcs.
  • Some fuses have ratings not within standard values, indicating special applications.
Overview
Detailed specifications and standards for various types of cylindrical fuses, including dimensions, characteristics, voltage ratings, and approvals.
Specifications
  • Dimensions: Primarily 6.3x32 mm and 5x20 mm.
  • Voltage Ratings: Common ratings include 32V, 125V, 250V, 500V, and up to 1000V.
  • Breaking Capacity: Ranges from 35A to 1500A.
  • Body Material: Glass or ceramic, some filled with sand.
Standards and Approvals
  • Comply with standards like UL 248-14, DIN 41572, UNEL 75112, BS 1362, and IEC 269-3A.
  • Approval codes include Bussmann AGC, MDL, ABC, MDA, and TDC series.
Applications
  • Designed for military, railway signaling, telecommunications, and general electrical protection.
  • Specific fuses for English plugs and adaptors, adhering to BS standards.
Performance Characteristics
  • Time-Current Characteristics: Fuses categorized as fast (F) or time delay (T).
  • Voltage Drop and I2t Values: Detailed for each fuse type.
Ordering Information
  • Available in various packaging options, with minimum order quantities specified.
  • Lead times for delivery range from 30 to 90 days.
Overview
Technical specifications and characteristics of various types of fuses, including box fuses and cylindrical fuses.
Specifications
  • Box Fuses: Rated currents range from 50 mA to 30 A.
  • Cylindrical Fuses: Similar specifications to box fuses.
Time-Current Characteristics
  • Fuses categorized by time delay characteristics.
  • Standards referenced include EN 60127.2.1, VDE 0820, CEI 32.6.2, BS 4265, SEMKO 104, and DIN 41661.
Key Data from Tables
  • Each fuse type listed with rated current, code, voltage drop, breaking capacity, and I2t value.
  • Time-current graphs illustrate response times under different test currents.
Recommendations
  • Ensure compatibility with specified standards when selecting fuses.
  • Consider time-current characteristics to match fuse performance with application requirements.
Overview
Technical specifications and standards for various types of box fuses, including BT307, BT309, BT311, BT315, and others.
Specifications Each fuse type detailed with rated current range, time-current characteristics, and dimensions.
Standards and Compliance Fuses comply with standards like IEC 60127-4 and UL 198 G.
Time-Current Characteristics Detailed graphs and tables showing time to open at various multiples of rated current.
Applications and Advantages Suitable for printed circuits, lighting ballasts, capacitors, and power cordsets.
Product Variants Lists various product codes and specifications, including fast-acting and time-delay characteristics.
Environmental and Mechanical Data Tested for life expectancy, load humidity, moisture resistance, thermal shock, and mechanical shock.
Ordering and Packaging Information on ordering, packaging, and product codes provided.
Specifications Outlines specifications for Brick™ Fuses, specifically the 6125FA and 6125TD series.
Environmental Data Tested under conditions like 100 G's peak shock, vibration, and salt spray exposure.
Electrical Characteristics Rated for various current levels, with specific opening times at 100% and 200% of amp rating.
Ordering and Soldering Customers advised to specify product and packaging codes when ordering.
Agency Information Fuses have UL Recognition and CSA Component Acceptance.
Key Data from Tables Detailed electrical characteristics for each fuse model.
Specifications Provides detailed specifications for various types of fuses, including dimensions, characteristics, voltage, breaking capacity, body material, and terminal material.
Procedures Outlines test current procedures for rated currents.
Standards and Approvals Comply with various international standards.
Recommendations Availability upon request for certain fuse ratings.
Key Data from Tables Detailed information on rated currents, voltage drops, I2t values, and resistance.
Critical Information Importance of selecting the correct fuse type based on application requirements.
Specifications Provides detailed specifications for various types of fuses, including rated current, test current, and time-current characteristics.
Procedures Outlines procedures for testing fuses.
Standards and Approvals Comply with standards like IEC 127-4 and UL 248-14.
Recommendations Using fuses for applications like battery chargers, portable computers, automotive systems, and transformers.
Key Data from Tables and Graphs Includes tables and graphs illustrating time-current characteristics.
General Information Provides general information about the use of PTC materials in fuses.
Current Characteristics Fuzetec resettable fuse's trip current and hold current rated at 23°C.
Electrical Characteristics Detailed specifications for various Fuzetec fuse models.
Technology Polymeric PTC material and device technology.
Operation Fuzetec resettable fuses designed with patented polymeric PTC material.
Tables and Graphs Includes tables detailing specifications of various fuse models.
Overview Provides detailed technical specifications and characteristics of various fuse series used in automotive and industrial applications.
Fuse Series and Specifications
  • FSMD Series: Includes various models with different current ratings and time-to-trip characteristics.
  • FRV Series: Models focusing on time-current characteristics.
  • FSMD-1210 and FSMD-1206 Series: Detailed marking and current ratings.
  • FSR and FLT Series: Includes marking and time-current characteristics.
  • FLR, FVT, FVL, and FSL Series: Specifications for different models with emphasis on automotive applications.
Key Characteristics
  • Time-Current Curves: Essential for matching fuses with anticipated overcurrent loads.
  • Voltage and Breaking Capacity: Most fuses rated at 32 Vdc with a breaking capacity of 1000 A.
  • Standards Compliance: Comply with standards like SAE J2077, SAE J1284, and FIAT 9.91806.
Applications
  • Automotive applications including car accessories, alarms, and refrigerators.
  • Industrial applications such as lifts and battery protection.
Advantages
  • Wide range of products with prompt delivery and easy availability.
  • Low cost and compliance with international standards.
Conclusion Comprehensive guide for selecting the appropriate fuse for specific automotive and industrial applications.
Specifications Provides detailed specifications for various types of fuses and fuseholders.
Procedures Outlines availability of certain products upon request.
Standards and Norms References compliance with standards like UL94-V0 and IEC 529.
Recommendations Using additional protection against electric shock for certain fuseholders.
Key Data from Tables and Diagrams Includes tables listing various fuse codes, rated currents, and corresponding colors.
Applications Use in printed circuit boards, medical equipment, lighting, televisions, and telecommunication systems.
Critical Information Need for additional protection for certain categories of fuseholders.
Specifications Describes terminal blocks available in versions from 1 to 5 poles.
Procedures Terminal blocks incorporate a fuse holder and are available in versions from 1 to 5 poles.
Standards and Norms Conform to standards like EN60998, UL1059, and C22.2 n°158.
Recommendations Users can cut the block in 36-pole or 18-pole sections according to their needs.
Key Data from Tables Detailed specifications for various models of terminal blocks.
Specifications Terminal blocks with various voltage and current ratings.
Procedures and Recommendations Terminal blocks can be assembled with vertical or horizontal type codes.
Product Variants Available in different configurations with varying numbers of poles and dimensions.
Key Data from Tables Detailed dimensions and codes for various terminal block configurations.
Critical Information Ensure products meet specified standards for safety and performance.
Specifications Outlines various thermostats and thermal protection devices.
Procedures Temperature ratings can be customized upon request.
Norms and Standards Products comply with international standards like IEC 934.
Recommendations Adhere to specified working cycles and voltage/current ratings.
Key Data from Tables Detailed specifications for various models.
General Information Importance of CE marking and international approvals.
Quality Approvals and Standards Importance of quality approvals like IMQ, SEMKO, and UDE.
CE Marking Visual demonstration of compliance with European Community Council Directives.
General Sales Conditions Sales conditions for Omega Fusibili and Omega Composants.
General Sales Conditions Payment must be made promptly, and disputes should be raised within 10 days.
Marks and Logos Buyers prohibited from using OMEGA marks or logos without authorization.
Catalogue Reproduction Reproduction of the catalogue is forbidden without consent.
Property of Designs and Technical Studies All designs and technical studies remain OMEGA's exclusive property.
Personal Data Treatment Personal data processed to provide commercial information efficiently.
Jurisdiction Milan Court of Law is the competent authority for Italian market disputes.
Shipping Costs within France Shipping costs vary by weight and region.
Product Index Includes an index of various fuse series and related products.
See more

Catalog excerpts

EUROPEAN CATALOGUE 2012 - ELECTRONIC-3

www.omegafusibili.it 1 Negli ultimi anni Omega è stata impegnata in importanti investimenti per poter affrontare la sfida commerciale del prossimo decennio con un’organizzazione rinnovata e moderna. Pur attraversando la peggior crisi politico-economica globale abbiamo portato a termine acquisizioni di grande importanza, trasformando Omega in un gruppo composto oggi da quattro diverse aziende, con 85 collaboratori interni ed oltre 60 agenti in diversi Paesi europei. Recentemente inaugurata, la nuova sede di Assago con ampi e luminosi uffici, vanta magazzini totalmente automatizzati al servizio...

 Open the catalog to page 3
EUROPEAN CATALOGUE 2012 - ELECTRONIC-4

Presentazione SEDE ITALIANA Italian head office Siège italien ¡ 1.200 mq uffici commerciali 1.200 sqm commercial office | 1.200 m2 de bureaux ¡ 3.200 mq magazzini 3.200 sqm warehouse | 3.200 m2 de stock ¡ 2.800 spazi bancale 2.800 pallet spaces | 2.800 emplacements palettes ¡ 6.500 ubicazioni 6.500 locations | 6.500 emplacements produits ¡ Logistica automatizzata Automated logistic | Logistique automatisée 2 www.omegafusibili.it PRESENTAZIONE Presentation Présentation

 Open the catalog to page 4
EUROPEAN CATALOGUE 2012 - ELECTRONIC-5

RAPPRESENTATE Partners Partenaires www.omegafusibili.it 3 SEDE FRANCESE French branch office Siège francais

 Open the catalog to page 5
EUROPEAN CATALOGUE 2012 - ELECTRONIC-6

Electronic 4 www.omegafusibili.it INDICE Index Index LEGENDA SIMBOLI Legends of symbols Légende des symboles INFORMAZIONI | Information | Informations CONFEZIONE | Packaging | Conditionnement GRADO DI PROTEZIONE | Sealing | Degré de protection PRESTARE ATTENZIONE | To be given special attention | Prêter attention CONSEGNA | Delivery | Livraison IPXX

 Open the catalog to page 6
EUROPEAN CATALOGUE 2012 - ELECTRONIC-7

www.omegafusibili.it 5 FUSIBILI CILINDRICI | Cylindrical fuses | Fusibles cylindriques ¡ Pag. 06 FUSIBILI IN VETRO | Glass fuses | Fusibles en verre FUSIBILI IN CERAMICA | Ceramic fuses | Fusibles en ceramique FUSIBILI OMOLOGATI | Approved fuses | Fusibles homologues FUSIBILI UL-CSA | UL-CSA approved fuses | Fusibles ul-csa FUSIBILI SPECIALI | Special fuses | Fusibles speciaux FUSIBILI PER SPINE INGLESI | Fuses for english plugs | Fusibles pour prises anglaises BOX FUSES | Box fuses | Box fuses FUSIBILI DA C.S. | PCB fuses | Fusibles pour circuit imprimé ¡ Pag. 40 POLYTRON | Polytron | Polytron...

 Open the catalog to page 7
EUROPEAN CATALOGUE 2012 - ELECTRONIC-8

Electronic FUSIBILI CILINDRICI Cylindrical fuses Fusibles cylindriques 6 www.omegafusibili.it

 Open the catalog to page 8
EUROPEAN CATALOGUE 2012 - ELECTRONIC-9

PRODUTTORI | Manufacturers | Producteurs FUSIBILI IN VETRO | Glass fuses | Fusibles en verre FUSIBILI IN CERAMICA | Ceramic fuses | Fusibles en céramique FUSIBILI OMOLOGATI | Approved fuses | Fusibles homologués FUSIBILI UL-CSA | UL-CSA approved fuses | Fusibles UL-CSA FUSIBILI SPECIALI | Special fuses | Fusibles spéciaux FUSIBILI PER SPINE INGLESI | Fuses for english plugs | Fusibles pour fiches anglaises BOX FUSES | Box fuses | Box fuses DIMENSIONI Dimensions Dimensions Esistono diverse misure di fusibili elettronici, inclusi i fusibili sub-miniaturizzati. I formati cilindrici più comuni sono...

 Open the catalog to page 9
EUROPEAN CATALOGUE 2012 - ELECTRONIC-10

Electronic INFORMAZIONI GENERALI General Information Informations Générales ¡ Tecnologia di base dei fusibili I fusibili in miniatura servono a due scopi principali: a) per proteggere componenti, apparecchiature e persone dal pericolo di incendi e shock causati da sovraccarichi di corrente. b) per isolare dei sotto sistemi dal sistema principale quando si verifica un guasto. ¡ I sovraccarichi I sovraccarichi si verificano quando viene superato il carico di corrente normale di un circuito. Può essere sia un sovraccarico che un corto circuito. Un sovraccarico è un qualsiasi flusso di corrente che...

 Open the catalog to page 10
EUROPEAN CATALOGUE 2012 - ELECTRONIC-11

¡ Basic Fuse Technology Miniature fuses serve to two main purposes: a) to protect components, equipment and people from risk of fire and shock risk caused by overcurrents. b) to isolate subsystems from the main system once a fault has occurred. ¡ Overcurrents Overcurrents exist when the normal load for a circuit is exceeded. It can be either an overload or short circuit. An overload is any current flowing within the normal circuit path that is higher than the normal circuit full load current. A short circuit is an overcurrent which greatly exceeds the normal full load current of the circuit....

 Open the catalog to page 11
EUROPEAN CATALOGUE 2012 - ELECTRONIC-12

Electronic INFORMAZIONI GENERALI General Information Informations Générales ¡ Corrente nominale Ogni fusibile è marcato con una corrente nominale. Diversi fattori possono influire sulla capacità del fusibile di portare la sua corrente nominale. In primo luogo il materiale della pinzetta/clip su cui il fusibile è montato può interferire con la prestazione del fusibile. Un altro fattore importante è la misura del conduttore usato per connettere il fusibile agli altri componenti del circuito: se il conduttore è troppo piccolo genera calore. Il fusibile sente il calore extra e si apre in anticipo....

 Open the catalog to page 12
EUROPEAN CATALOGUE 2012 - ELECTRONIC-13

¡ Current ratings Each fuse is marked with a nominal current rating. Several factors can affect the ability of the fuse to carry this rated current. First the base material of the clip in which the fuse is mount-ed may greatly affect the performance of the fuse. Another important factor is the conductor size used to connect the fuse to other circuit components. If the conductor is too small, it will generate heat. That extra heat will be seen by the fuse, causing the fuse to open before it should. It is also important that the fuse be installed with clean and tight connections. If the connections...

 Open the catalog to page 13
EUROPEAN CATALOGUE 2012 - ELECTRONIC-14

Electronic GLOSSARIO Glossary of terms Glossaire ¡ Quadrato del valore della corrente moltiplicato per il tempo I2t Si tratta della quantità di calore fornita a un circuito nel momento in cui il fusibile interviene su un guasto. Si può esprimere coi termini “I2t di fusione”, “ I2t dell’arco” oppure la somma dei due detta “ I2t di interruzione”. Questa è solitamente usata come misura di attuazione di un corto circuito. ¡ Tempo di arco È il periodo di tempo che intercorre tra l’istante di fusione del fusibile e il momento in cui il sovraccarico è interrotto. ¡ Tempo di intervento È il periodo di...

 Open the catalog to page 14

All OMEGA FUSIBILI catalogs and technical brochures

  1. AIR MOVING 2020

    158  Pages

  2. ELECTRONIC 2016

    30  Pages

  3. AIR MOVING 2016

    84  Pages

  4. POWER 2016

    174  Pages

  5. CONNECTION 2016

    148  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.