RDP series
2Pages

{{requestButtons}}

Catalog excerpts

RDP series - 1

RDP SERIESREFRIGERATION COMPRESSED AIR DRYERS 14 bar max. operating pressure 1,5 to 45 °c operating ambient temperature 3°c pressure dew point 20to 13.200 Nm5/h flow rate R134a (R407c) refrigerant aircooled type of cooling DESCRIPTION RDP refrigeration dryers have been designed to effectively separate water from the compressed air thus lower pressure dew point all the way down to +3°C. Drying is achieved on the principle of cooling which takes place inside highly efficient and ultra-compact 3 stage heat exchanger. In the first stage (air-air heat exchanger) hot and humid inlet air is being precooled by the cold outgoing air. In the second stage (air-refrigerant heat exchanger) intensive water condensation takes place due to cooling the air. All condensed water is separated from the main compressed air stream in the third stage by the integrated demister. A proven and robust design enables efficient and reliable operation, fast installation and simple maintenance. APPLICATIONS • Compressed air systems • Sized to match standard compressor outputs

Open the catalog to page 1
RDP series - 2

CORRECTION FACTOR FOR OPERATING PRESSURE CHANGES Operating pressure [bar] Operating pressure [bar] Correction factor Temperature [°C] Temperature [°F] Correction factor CORRECTION FACTOR FOR DEW POINT CHANGES 3 37,4 1,00 G 3/8" BSP-F G 3/8" BSP-F G 3/4” BSP-F G 3/4" BSP-F G 3/4" BSP-F G1” BSP-F G1” BSP-F GV BSP-F G1V2” BSP-F G1V," BSP-F G17,” BSP-F G 2” BSP-F G 2" BSP-F G 2” BSP-F G21/; BSP-F G 2 V/' BSP-F G 27,” BSP-F DN80 DN100 DN100 DN125 DN125 DN150 DN150 DN200 DN200 DN200 ■ 10 50 1,385 CORRECTION FACTOR FOR INLET TEMPERATURE CHANGES CORRECTION FACTOR FOR AMBIENT TEMPERATURE CHANGES <25...

Open the catalog to page 2

All OMEGA AIR d.o.o. Ljubljana catalogs and technical brochures

  1. WFIF SERIES

    2 Pages

  2. WHFIT SERIES

    2 Pages

  3. MEGA TOOLS

    12 Pages

  4. ACW series

    1 Pages

  5. ACA series

    1 Pages

  6. RDHP series

    2 Pages

  7. RDF

    2 Pages

  8. RDL series

    2 Pages

  9. M-DRY series

    2 Pages

  10. X-DRY series

    2 Pages

  11. A-DRY TAC

    2 Pages

  12. PV

    2 Pages

  13. OCI

    1 Pages

  14. SF series

    2 Pages

  15. WFIW series

    2 Pages

  16. MSS

    2 Pages

  17. MDH 400

    1 Pages

  18. CHI

    1 Pages

  19. VPG 60

    1 Pages

  20. AOK 50SS

    1 Pages

  21. EVD series

    1 Pages

  22. A-CAT series

    2 Pages

  23. SFH HP

    2 Pages

  24. TP series

    1 Pages

  25. BS TOWER

    1 Pages

  26. PETRO-PACK

    1 Pages

  27. AWS

    1 Pages

  28. BS 12-3,5

    1 Pages

  29. OWT

    2 Pages

  30. OWE/HWE

    2 Pages

  31. OWB

    2 Pages

  32. OBE SERIES

    2 Pages

  33. ECD-B series

    2 Pages

  34. MDHI 50

    1 Pages

  35. BF series

    2 Pages

  36. HPF series

    2 Pages

  37. IHP series

    2 Pages

  38. PF series

    2 Pages

  39. EPG 60

    1 Pages

  40. MDM40

    1 Pages

  41. OCI

    1 Pages

  42. AV series

    2 Pages

  43. SPF series

    2 Pages

  44. MDM60

    1 Pages

  45. MDH

    1 Pages