Heatless regenerated adsorption dryers - B-DRY, F-DRY
1 /8Pages

Heatless regenerated adsorption dryers - B-DRY, F-DRY

Heatless regenerated adsorption dryers - B-DRY, F-DRY
1 /8Pages

Catalog excerpts

Heatless regenerated adsorption dryers - B-DRY, F-DRY-1

Heatless regenerated adsorption dryers

 Open the catalog to page 1
Heatless regenerated adsorption dryers - B-DRY, F-DRY-2

B-DRY / F-DRY - Heatless regenerated adsorption dryers Four individually controlled valves To provide optimum control over the complete drying process four high quality electromagnetic valves are used. Individual control of each valve results in column switch-over without any pressure peaks. Compact control blocks Compact and robust design of upper and lower control valve block assures reliable operation. Purge air line is mounted on upper check valve block so that purge air nozzle can be replaced if required. During maintenance complete block can be removed from the dryer in one piece. Two manometers...

 Open the catalog to page 2
Heatless regenerated adsorption dryers - B-DRY, F-DRY-3

ADSORPTION DRYER Compressed air contains contaminants such as water, oil and particulates which must be removed or reduced to the acceptable level based on specific application requirements. Standard ISO8573-1 specifies air purity/quality classes for these contaminants. Humidity (water vapor content) is expressed in the terms of Pressure Dew Point (PDP), where Dew point is the temperature at which air is 100% saturated with moisture. When the temperature of the air is reduced to or below the dew point, condensation will occur. Typical applications for the adsorption dryers are outdoor installations...

 Open the catalog to page 3
Heatless regenerated adsorption dryers - B-DRY, F-DRY-4

B-DRY / F-DRY - Heatless regenerated adsorption dryers Compressed air inlet (wet air) Compressed air outlet (dry air) Column filled with dessicant Two layer desiccant bed Controller Solenoid valve Expansion silencer Non-returning valve Nozzle Pressure manometer Inlet air filter Outlet air filter Automatic condensate drain Flow distribution insert Cable for solenoid valve (optional) Dew point sensor (optional) B-DRY and F-DRY adsorption dryers have been designed for continuous separation of water vapor from the compressed air thus reducing the pressure dew point. Adsorption takes place under pressure...

 Open the catalog to page 4
Heatless regenerated adsorption dryers - B-DRY, F-DRY-5

B-DRY / F-DRY - Heatless regenerated adsorption dryers

 Open the catalog to page 5
Heatless regenerated adsorption dryers - B-DRY, F-DRY-6

B-DRY / F-DRY - Heatless regenerated adsorption dryers Easy maintenance When FIX operating cycle is selected or when the dryer is not equipped with a dew point sensor it will operate in pre-set operating cycles meaning length of adsorption and regeneration will be fixed. Energy losses are directly related with an amount of purge air which is used for regeneration. B-DRY and F-DRY energy losses have been optimized due to the 10 minute operating cycle: Upper and lower control valve can be removed from the dryer in one piece. All components that are subject to wear are easily accessible and replaceable....

 Open the catalog to page 6
Heatless regenerated adsorption dryers - B-DRY, F-DRY-7

B-DRY / F-DRY - Heatless regenerated adsorption dryers Technical data TECHNICAL DATA B-DRY 110-1000 Nominal volume flow Connection IN/OUT TECHNICAL DATA F-DRY 1200-6500 Nominal volume flow Connection IN/OUT Voltage, frequency Power consumption Protection class Filter (inlet)* Filter (outlet) Operating temperature range Operating pressure range OPERATING PRESSURE - CORRECTION FACTORS - COP Operating pressure [bar] Operating pressure [psi] Correction factor COP OPERATING TEMPERATURE - CORRECTION FACTORS - COT Operat. temperature [°C] DEW POINT - CORRECTION FACTORS - CD 55 Refers to 1bar(a) and...

 Open the catalog to page 7
Heatless regenerated adsorption dryers - B-DRY, F-DRY-8

T +386 (0)1 200 68 00 [email protected] Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia www.omega-air.si

 Open the catalog to page 8

All OMEGA AIR d.o.o. Ljubljana catalogs and technical brochures

  1. WFIF SERIES

    2  Pages

  2. WHFIT SERIES

    2  Pages

  3. MEGA TOOLS

    12  Pages

  4. ACW series

    1  Page

  5. ACA series

    1  Page

  6. RDHP series

    2  Pages

  7. RDF

    2  Pages

  8. RDL series

    2  Pages

  9. RDP series

    2  Pages

  10. M-DRY series

    2  Pages

  11. HP-DRY series

    2  Pages

  12. X-DRY series

    2  Pages

  13. A-DRY TAC

    2  Pages

  14. PV

    2  Pages

  15. OCI

    1  Page

  16. SF series

    2  Pages

  17. WFIW series

    2  Pages

  18. MSS

    2  Pages

  19. MDH 400

    1  Page

  20. CHI

    1  Page

  21. VPG 60

    1  Page

  22. AOK 50SS

    1  Page

  23. EVD series

    1  Page

  24. RC-DRY series

    2  Pages

  25. TAC HP series

    2  Pages

  26. A-CAT series

    2  Pages

  27. SFH HP

    2  Pages

  28. TP PED series

    2  Pages

  29. TP series

    1  Page

  30. BS TOWER

    1  Page

  31. PETRO-PACK

    1  Page

  32. AWS

    1  Page

  33. BS 12-3,5

    1  Page

  34. OWT

    2  Pages

  35. OWE/HWE

    2  Pages

  36. OWB

    2  Pages

  37. OBE SERIES

    2  Pages

  38. ECD-B series

    2  Pages

  39. MDHI 50

    1  Page

  40. MDH

    1  Page

  41. MDM60

    1  Page

  42. SPF series

    2  Pages

  43. AV series

    2  Pages

  44. OCI

    1  Page

  45. MDM40

    1  Page

  46. EPG 60

    1  Page

  47. PF series

    2  Pages

  48. IHP series

    2  Pages

  49. HPF series

    2  Pages

  50. BF series

    2  Pages

Archived catalogs

  1. Biogas plants

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.