Heatless regenerated adsorption dryers
Open the catalog to page 1B-DRY / F-DRY - Heatless regenerated adsorption dryers Four individually controlled valves To provide optimum control over the complete drying process four high quality electromagnetic valves are used. Individual control of each valve results in column switch-over without any pressure peaks. Compact control blocks Compact and robust design of upper and lower control valve block assures reliable operation. Purge air line is mounted on upper check valve block so that purge air nozzle can be replaced if required. During maintenance complete block can be removed from the dryer in one piece. Two...
Open the catalog to page 2ADSORPTION DRYER Compressed air contains contaminants such as water, oil and particulates which must be removed or reduced to the acceptable level based on specific application requirements. Standard ISO8573-1 specifies air purity/quality classes for these contaminants. Humidity (water vapor content) is expressed in the terms of Pressure Dew Point (PDP), where Dew point is the temperature at which air is 100% saturated with moisture. When the temperature of the air is reduced to or below the dew point, condensation will occur. Typical applications for the adsorption dryers are outdoor...
Open the catalog to page 3B-DRY / F-DRY - Heatless regenerated adsorption dryers Compressed air inlet (wet air) Compressed air outlet (dry air) Column filled with dessicant Two layer desiccant bed Controller Solenoid valve Expansion silencer Non-returning valve Nozzle Pressure manometer Inlet air filter Outlet air filter Automatic condensate drain Flow distribution insert Cable for solenoid valve (optional) Dew point sensor (optional) B-DRY and F-DRY adsorption dryers have been designed for continuous separation of water vapor from the compressed air thus reducing the pressure dew point. Adsorption takes place under...
Open the catalog to page 4B-DRY / F-DRY - Heatless regenerated adsorption dryers
Open the catalog to page 5B-DRY / F-DRY - Heatless regenerated adsorption dryers Easy maintenance When FIX operating cycle is selected or when the dryer is not equipped with a dew point sensor it will operate in pre-set operating cycles meaning length of adsorption and regeneration will be fixed. Energy losses are directly related with an amount of purge air which is used for regeneration. B-DRY and F-DRY energy losses have been optimized due to the 10 minute operating cycle: Upper and lower control valve can be removed from the dryer in one piece. All components that are subject to wear are easily accessible and...
Open the catalog to page 6B-DRY / F-DRY - Heatless regenerated adsorption dryers Technical data TECHNICAL DATA B-DRY 110-1000 Nominal volume flow Connection IN/OUT TECHNICAL DATA F-DRY 1200-6500 Nominal volume flow Connection IN/OUT Voltage, frequency Power consumption Protection class Filter (inlet)* Filter (outlet) Operating temperature range Operating pressure range OPERATING PRESSURE - CORRECTION FACTORS - COP Operating pressure [bar] Operating pressure [psi] Correction factor COP OPERATING TEMPERATURE - CORRECTION FACTORS - COT Operat. temperature [°C] DEW POINT - CORRECTION FACTORS - CD 55 Refers to 1bar(a)...
Open the catalog to page 7T +386 (0)1 200 68 00 info@omega-air.si Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia www.omega-air.si
Open the catalog to page 8All OMEGA AIR d.o.o. Ljubljana catalogs and technical brochures
-
Catalogue - Product overview
72 Pages
-
Screw compressors MA SD 2-3
2 Pages
-
MA SD 7,5-15 VS /BDK
2 Pages
-
Piston compressors - MEGA AIR
12 Pages
-
Container and Skid units
8 Pages
-
WFIF SERIES
2 Pages
-
WHFIT SERIES
2 Pages
-
MEGA TOOLS
12 Pages
-
MEGA AIR QUALITY OILS
8 Pages
-
CO2-R-DRY series
2 Pages
-
ACW series
1 Pages
-
ACA series
1 Pages
-
RDHP series
2 Pages
-
RDF
2 Pages
-
RDL series
2 Pages
-
RDP series
2 Pages
-
M-DRY series
2 Pages
-
HP-DRY series
2 Pages
-
R-DRY BVL series
2 Pages
-
R-DRY BP series
2 Pages
-
COM-DRY series
2 Pages
-
X-DRY series
2 Pages
-
A-DRY TAC
2 Pages
-
A-DRY BI+BM series
2 Pages
-
PV
2 Pages
-
AIR AND GAS Product overview
2 Pages
-
Compact oxygen generators
2 Pages
-
Compact nitrogen generators
2 Pages
-
SKID based solutions
2 Pages
-
Biogas plants
8 Pages
-
OCI
1 Pages
-
CKL-IHP series
2 Pages
-
SF series
2 Pages
-
WFIW series
2 Pages
-
MSS
2 Pages
-
MDH 400
1 Pages
-
CHI
1 Pages
-
VPG 60
1 Pages
-
FA - flange adapter
1 Pages
-
TD 400M series
1 Pages
-
AOK 50SS
1 Pages
-
EVD series
1 Pages
-
RC-DRY series
2 Pages
-
HPR-DRY series
2 Pages
-
TAC HP series
2 Pages
-
A-CAT series
2 Pages
-
SFH HP
2 Pages
-
TP PED series
2 Pages
-
TP ASME series
1 Pages
-
TP series
1 Pages
-
BS TOWER
1 Pages
-
PETRO-PACK
1 Pages
-
AWS
1 Pages
-
BS 12-3,5
1 Pages
-
AIRWATT series
2 Pages
-
B-AIR plus series
2 Pages
-
OWT
2 Pages
-
OWE/HWE
2 Pages
-
OWB
2 Pages
-
OBE SERIES
2 Pages
-
ECD-B series
2 Pages
-
MDHI 50
1 Pages
-
BF series
2 Pages
-
HPF series
2 Pages
-
AK- assembly kit for filters
1 Pages
-
IHP series
2 Pages
-
PF series
2 Pages
-
EPG 60
1 Pages
-
MDM40
1 Pages
-
OCI
1 Pages
-
AV series
2 Pages
-
SPF series
2 Pages
-
CS /CS SS series
2 Pages
-
SFH /SFH SS series
2 Pages
-
CKL-CHP series
2 Pages
-
MDM60
1 Pages
-
MDH
1 Pages
-
PROCESS AND STERILE FILTRATION
12 Pages
-
SORBEO Adsorbents
2 Pages